@20:29:10.15PST30-Jan-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @20:29:13.76 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @20:29:18.48 Polling Can every 10:00 @20:29:18.50 Cleanly exited at 20:25:07PST30-Jan-20 @20:29:18.96 Clients may connect on TCP port 9999 @20:29:18.97 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @20:29:19.06 Starting goMexTank20jan mission in /home/esp/esp2/mission/long/goMexTank20jan.rb @20:29:19.56 Shutdown @20:29:19.62
Asleep / Shutdown @20:29:19.68 Powering down until 20:40 @20:29:49.73 Sending Email @20:32:12.18 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @20:32:12.20 Retry #1 of 10 after 3:00 @20:34:49.77 Email::Error in MAIN -- flush stuck! @20:39:23.22PST30-Jan-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @20:39:27.03 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @20:39:31.48 Polling Can every 10:00 @20:39:31.51 Cleanly exited at 20:29:19PST30-Jan-20 @20:39:31.98 Clients may connect on TCP port 9999 @20:39:31.99 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @20:39:32.11 Continuing goMexTank20jan from /home/esp/esp2/mission/long/goMexTank20jan.rb:11 @20:39:32.18 Waiting until 20:40 @20:40:00.07 Powering core bus @20:40:07.08 All dwarf controllers running firmware version 3.85 @20:40:23.62 Phase [at('1/30/20 8:40pm') {archive} #1st QC in Test Tank] @20:40:23.63 Archive #1 on Thursday @20:40:23.65 Starting initialPurge @20:40:23.66 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @20:40:38.29 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.46 @20:40:41.65 Flushing the Collection Valve::Manifold @20:40:47.34 Pulling 5ml of CSR.flush @20:41:25.37 CTD battery = 10.200V @20:41:34.06
Purging external Intake @20:42:22.26 Flushing upper manifold @20:44:10.03 Garaging FlushPuck in Collection Clamp @20:44:23.69 Starting stand-alone bac WCR @20:44:23.71 bac wcr sampling at most 520ml @20:44:23.76 Whole Cell Archive sampling 520ml @20:44:23.80 RuntimeError in MAIN -- No Storage.srcTube defined! @20:44:24.01 Waiting to Resume from Checkpoint "Whole Cell Archive sampling 520ml" @20:45:00.31 Session Begun @20:45:10.18 -> MainThread.exit @20:45:22.74 -> startTube 2 @20:45:24.29 -> pucks @20:45:40.22
Sending Email @20:45:47.87 -> exit @20:45:47.89 Session Ended @20:46:25.32 Session Begun @20:46:31.17 -> MainThread.exit @20:46:31.19 Email::Error in MAIN -- flush stuck! @20:46:31.33 ThreadError in brent -- killed thread @20:46:31.41 Session Ended @10:56:35.19PST31-Jan-20
>OVERRUN< ESP2 v3.41 I2C Gateway v3.20 for core bus @10:56:38.80 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @10:56:43.39 Polling Can every 10:00 @10:56:47.21 All dwarf controllers running firmware version 3.85 @10:56:47.34 Cleanly exited at 20:46:31PST30-Jan-20 @10:56:47.78 Clients may connect on TCP port 9999 @10:56:47.80 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @10:56:48.31 Starting goMexTank20jan mission in /home/esp/esp2/mission/long/goMexTank20jan.rb @10:56:48.81 Waiting until 11:00 @10:57:09.57 CTD battery = 10.200V @10:59:34.60 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @10:59:34.62 Retry #1 of 10 after 3:00 @11:00:00.71
Phase [at('1/31/20 11am') {archive} #1st QC in Test Tank] @11:00:00.73 Archive #1 on Friday @11:00:00.74 Starting initialPurge @11:00:00.76 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @11:00:12.96 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.48 @11:00:14.93 Flushing the Collection Valve::Manifold @11:00:16.37 Pulling 4.999ml of CSR.flush @11:01:02.10 Purging external Intake @11:01:51.32 Flushing upper manifold @11:03:40.83 Garaging FlushPuck in Collection Clamp @11:03:56.82 Starting stand-alone bac WCR @11:03:56.84 bac wcr sampling at most 520ml @11:03:56.90 Whole Cell Archive sampling 520ml @11:03:56.93 Loading wcr puck from tube 2 into Collection Clamp @11:04:14.01 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.52 @11:04:16.04 collectSample 520ml w/bubble point of 55psi @11:04:16.06 Priming 7ml @11:04:16.52 Calibrating pressure and temperature sensors @11:04:31.00 Waiting for external sampler to finish priming... @11:04:47.23 6.2L/min @11:05:17.31 6.2L/min @11:05:47.37 6.1L/min @11:06:17.45 6.1L/min @11:06:47.52 6.1L/min @11:07:17.60 6.1L/min @11:07:30.08 Sampling 520.0ml @11:07:39.84 EOFError in Qmail -- end of file reached @11:07:39.86 Retry #3 of 10 after 3:00 @11:07:47.67 6.1L/min @11:08:17.73 6.1L/min @11:08:47.79 6.1L/min @11:09:17.86 6.1L/min @11:09:47.92 6.1L/min @11:10:17.98 6.1L/min @11:10:48.05 6.1L/min @11:11:18.12 6.1L/min @11:11:48.21 6.1L/min @11:12:18.32 6.1L/min @11:12:48.41 6.1L/min @11:13:18.48 6.1L/min @11:13:48.55 6.1L/min @11:14:18.69 6.1L/min @11:14:48.76 6.1L/min @11:15:03.70 EOFError in Qmail -- end of file reached @11:15:03.73 Retry #5 of 10 after 3:00 @11:15:18.82 6.1L/min @11:15:48.89 6.1L/min @11:16:18.96 6.1L/min @11:16:49.02 6.1L/min @11:17:10.32 Sampled 520.0ml @11:17:10.37 Drying puck before fixing for 4:00 @11:17:17.24 CTD battery = 10.200V @11:18:32.50 Pumping wcr puck from tube 2 up to 55psi... @11:20:49.71 Fix #1 of 2 (with rnal) for 2:00 @11:20:50.31 Pulling 2ml of CSR.rnal @11:21:18.18 Pumping wcr puck from tube 2 up to 55psi... @11:22:29.02 EOFError in Qmail -- end of file reached @11:22:29.04 Retry #7 of 10 after 3:00 @11:24:50.34 Fix #2 of 2 (with rnal) for 2:00 @11:24:50.84 Pulling 2ml of CSR.rnal @11:25:18.42 Pumping wcr puck from tube 2 up to 55psi... @11:28:03.57 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] @11:28:39.36 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] /usr/sbin/detachIridium: line 10: cannot open /dev/AT/iridium: Input/output error @11:28:45.71 Session Begun @11:28:45.75 -> Gate.cycleModemPower! 5 @11:28:45.80 Session Ended @11:28:50.46 Storing wcr puck in Collection Clamp to tube 1 @11:29:18.87 Starting finalPurge @11:29:18.89 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @11:29:32.65 Collection Clamp onSpring/offSpring for 9/25 samples, on/off torque 1.52 @11:29:34.70 Flushing the Collection Valve::Manifold @11:29:35.50 Pulling 5ml of CSR.flush @11:30:21.26 Flushing lower manifold's waste2b port @11:30:59.36 Disinfecting external Intake with kill @11:31:00.05 Pulling 8ml of CSR.kill @11:31:53.88 Pulling 5ml of CSR.flush @11:32:53.14 Garaging FlushPuck in Collection Clamp @11:33:06.56 Completed [at('1/31/20 11am') {archive} #1st QC in Test Tank] begun 11:00:00 @11:33:06.76 Asleep / Shutdown @11:33:07.31 Shutdown @11:33:07.34
Powering down until 23:00 @11:33:37.39 Sending Email @11:35:08.60 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] /usr/sbin/detachIridium: line 10: cannot open /dev/AT/iridium: Input/output error @11:35:14.89 Session Begun @11:35:14.94 -> Gate.cycleModemPower! 5 @11:35:14.98 Session Ended @22:59:24.29PST31-Jan-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @22:59:27.84 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @22:59:32.45 Polling Can every 10:00 @22:59:32.49 Cleanly exited at 11:33:07PST31-Jan-20 @22:59:32.97 Clients may connect on TCP port 9999 @22:59:32.98 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @22:59:33.17 Continuing goMexTank20jan from /home/esp/esp2/mission/long/goMexTank20jan.rb:12 @22:59:33.26 Waiting until 23:00 @23:00:00.06 Powering core bus @23:00:06.92 All dwarf controllers running firmware version 3.85 @23:00:20.71 Phase [at('11PM') {archive}] @23:00:20.74 Archive #2 on Friday @23:00:20.76 Starting initialPurge @23:00:20.77 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @23:00:35.78 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.50 @23:00:37.74 Flushing the Collection Valve::Manifold @23:00:39.16 Pulling 5ml of CSR.flush @23:01:24.86 Purging external Intake @23:01:28.07 CTD battery = 10.200V @23:02:14.47
Flushing upper manifold @23:04:04.39 Garaging FlushPuck in Collection Clamp @23:04:18.30 Starting stand-alone bac WCR @23:04:18.32 bac wcr sampling at most 520ml @23:04:18.38 Whole Cell Archive sampling 520ml @23:04:18.60 Loading wcr puck from tube 2 into Collection Clamp @23:04:37.22 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.55 @23:04:39.30 collectSample 520ml w/bubble point of 55psi @23:04:39.33 Priming 7ml @23:04:39.81 Calibrating pressure and temperature sensors @23:04:55.89 Waiting for external sampler to finish priming... @23:05:10.50 6.2L/min @23:05:40.59 6.2L/min @23:06:10.68 6.1L/min @23:06:40.76 6.1L/min @23:07:10.83 6.1L/min @23:07:40.90 6.1L/min @23:07:53.36 Sampling 520.0ml @23:08:10.97 6.1L/min @23:08:41.04 6.1L/min @23:09:11.10 6.1L/min @23:09:41.18 6.1L/min @23:10:11.27 6.1L/min @23:10:30.42 Session Begun @23:10:32.54 -> can @23:10:38.04 EOFError in Qmail -- end of file reached @23:10:38.07 Retry #2 of 10 after 3:00 @23:10:41.34 6.1L/min @23:11:11.41 6.1L/min @23:11:41.47 6.1L/min @23:12:11.53 6.1L/min @23:12:41.60 6.1L/min @23:13:11.67 6.1L/min @23:13:41.74 6.1L/min @23:14:11.80 6.1L/min @23:14:42.36 6.2L/min @23:15:12.49 6.1L/min @23:15:42.56 6.1L/min @23:16:12.63 6.1L/min @23:16:42.70 6.1L/min @23:17:12.79 6.1L/min @23:17:37.79 Sampled 520.0ml @23:17:37.87 Drying puck before fixing for 4:00 @23:17:44.74 CTD battery = 10.200V @23:18:39.30 EOFError in Qmail -- end of file reached @23:18:39.33 Retry #4 of 10 after 3:00 @23:19:00.05 Pumping wcr puck from tube 2 up to 55psi... @23:21:15.89 Fix #1 of 2 (with rnal) for 2:00 @23:21:16.46 Pulling 2ml of CSR.rnal @23:21:44.45 Pumping wcr puck from tube 2 up to 55psi... @23:25:18.15 Fix #2 of 2 (with rnal) for 2:00 @23:25:18.78 Pulling 2ml of CSR.rnal @23:25:19.04 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] /usr/sbin/detachIridium: line 10: cannot open /dev/AT/iridium: Input/output error @23:25:25.69 Session Begun @23:25:25.74 -> Gate.cycleModemPower! 5 @23:25:25.82 Session Ended @23:25:47.24 Pumping wcr puck from tube 2 up to 55psi... @23:25:56.95 -> exit @23:25:56.96 Session Ended @23:29:19.17 Storing wcr puck in Collection Clamp to tube 1 @23:29:48.86 Starting finalPurge @23:29:48.88 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @23:30:02.76 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.53 @23:30:04.76 Flushing the Collection Valve::Manifold @23:30:05.55 Pulling 5ml of CSR.flush @23:30:51.49 Flushing lower manifold's waste2b port @23:31:29.96 Disinfecting external Intake with kill @23:31:30.62 Pulling 8ml of CSR.kill @23:32:23.83 Pulling 5ml of CSR.flush @23:33:23.18 Garaging FlushPuck in Collection Clamp @23:33:36.47 Completed [at('11PM') {archive}] begun 23:00:20 @23:33:36.67 Asleep / Shutdown @23:33:37.25 Shutdown @23:33:37.28
Powering down until 10:00PST01-Feb-20 @23:34:07.33 Sending Email @23:36:40.42 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @23:36:40.44 Retry #1 of 10 after 3:00 @23:39:07.36 Email::Error in MAIN -- flush stuck! @09:59:23.28PST01-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @09:59:26.91 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @09:59:31.63 Polling Can every 10:00 @09:59:31.67 Cleanly exited at 23:33:37PST31-Jan-20 @09:59:32.16 Clients may connect on TCP port 9999 @09:59:32.17 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @09:59:32.41 Continuing goMexTank20jan from /home/esp/esp2/mission/long/goMexTank20jan.rb:14 @09:59:32.50 Waiting until 10:00 @10:00:00.07 Powering core bus @10:00:06.32 All dwarf controllers running firmware version 3.85 @10:00:19.85 Phase [at('10AM') {archive}] @10:00:19.87 Archive #3 on Saturday @10:00:19.91 Starting initialPurge @10:00:19.92 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @10:00:34.78 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.54 @10:00:36.75 Flushing the Collection Valve::Manifold @10:00:38.18 Pulling 5ml of CSR.flush @10:01:23.90 Purging external Intake @10:01:27.13 CTD battery = 10.200V @10:02:13.77
Flushing upper manifold @10:04:03.86 Garaging FlushPuck in Collection Clamp @10:04:17.51 Starting stand-alone bac WCR @10:04:17.53 bac wcr sampling at most 520ml @10:04:17.58 Whole Cell Archive sampling 520ml @10:04:17.62 Loading wcr puck from tube 2 into Collection Clamp @10:04:36.47 Collection Clamp onSpring/offSpring for 9/25 samples, on/off torque 1.52 @10:04:38.52 collectSample 520ml w/bubble point of 55psi @10:04:38.54 Priming 7ml @10:04:39.00 Calibrating pressure and temperature sensors @10:04:53.89 Waiting for external sampler to finish priming... @10:05:09.70 6.2L/min @10:05:39.81 6.2L/min @10:06:09.90 6.2L/min @10:06:39.99 6.2L/min @10:07:10.05 6.1L/min @10:07:30.18 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @10:07:30.21 Retry #1 of 10 after 3:00 @10:07:40.12 6.1L/min @10:07:54.24 Sampling 520.0ml @10:08:10.18 6.1L/min @10:08:40.25 6.1L/min @10:09:10.31 6.1L/min @10:09:40.38 6.1L/min @10:09:52.34 Session Begun @10:09:53.86 -> can @10:10:10.45 6.1L/min @10:10:40.52 6.1L/min @10:11:02.04 -> can @10:11:10.59 6.1L/min @10:11:40.68 6.1L/min @10:12:10.79 6.1L/min @10:12:27.98 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] /usr/sbin/detachIridium: line 10: cannot open /dev/AT/iridium: Input/output error @10:12:34.52 Session Begun @10:12:34.56 -> Gate.cycleModemPower! 5 @10:12:34.63 Session Ended @10:12:35.93 -> can @10:12:40.00 -> can @10:12:40.86 6.1L/min @10:12:46.71 -> can @10:13:10.93 6.1L/min @10:13:41.00 6.1L/min @10:14:11.06 6.1L/min @10:14:41.12 6.1L/min @10:15:11.19 6.1L/min @10:15:41.25 6.1L/min @10:16:11.32 6.1L/min @10:16:41.39 6.1L/min @10:17:11.45 6.1L/min @10:17:41.51 6.1L/min @10:18:11.58 6.1L/min @10:18:41.64 6.1L/min @10:19:11.70 6.1L/min @10:19:41.87 6.1L/min @10:19:49.89 Sampled 520.0ml @10:19:49.95 Drying puck before fixing for 4:00 @10:19:54.79 -> can @10:21:11.91 -> can @10:21:12.30 Pumping wcr puck from tube 2 up to 55psi... @10:21:24.90 CTD battery = 10.200V @10:22:09.76 -> can @10:23:28.43 Fix #1 of 2 (with rnal) for 2:00 @10:23:28.98 Pulling 2ml of CSR.rnal @10:23:56.93 Pumping wcr puck from tube 2 up to 55psi... @10:27:00.61 -> can @10:27:20.59 -> exit @10:27:20.60 Session Ended @10:27:28.68 Fix #2 of 2 (with rnal) for 2:00 @10:27:29.22 Pulling 2ml of CSR.rnal @10:27:57.06 Pumping wcr puck from tube 2 up to 55psi... @10:31:29.57 Storing wcr puck in Collection Clamp to tube 1 @10:31:58.33 Starting finalPurge @10:31:58.35 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @10:32:12.74 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.53 @10:32:14.75 Flushing the Collection Valve::Manifold @10:32:15.41 Pulling 5ml of CSR.flush @10:33:01.15 Flushing lower manifold's waste2b port @10:33:39.21 Disinfecting external Intake with kill @10:33:39.85 Pulling 8ml of CSR.kill @10:34:33.41 Pulling 5ml of CSR.flush @10:35:32.40 Garaging FlushPuck in Collection Clamp @10:35:46.58 Completed [at('10AM') {archive}] begun 10:00:19 @10:35:46.76 Asleep / Shutdown @10:35:47.33 Shutdown @10:35:47.36
Powering down until 21:00 @10:36:17.41 Sending Email pppd: In file /etc/ppp/peers/iridium: unrecognized option 'AT/iridium' @10:39:31.11 EOFError in Qmail -- end of file reached @10:39:31.14 Retry #2 of 10 after 3:00 @10:41:17.44 Email::Error in MAIN -- flush stuck! @20:59:24.08PST01-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @20:59:27.63 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @20:59:32.32 Polling Can every 10:00 @20:59:32.37 Cleanly exited at 10:35:47PST01-Feb-20 @20:59:32.83 Clients may connect on TCP port 9999 @20:59:32.85 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @20:59:33.14 Continuing goMexTank20jan from /home/esp/esp2/mission/long/goMexTank20jan.rb:15 @20:59:33.22 Waiting until 21:00 @21:00:00.06 Powering core bus @21:00:06.41 All dwarf controllers running firmware version 3.85 @21:00:20.06 Phase [at('9PM') {archive}] @21:00:20.09 Archive #4 on Saturday @21:00:20.10 Starting initialPurge @21:00:20.12 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @21:00:34.85 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.56 @21:00:36.86 Flushing the Collection Valve::Manifold @21:00:38.26 Pulling 4.999ml of CSR.flush @21:01:24.21 Purging external Intake @21:01:27.73 CTD battery = 10.200V @21:02:14.33
Flushing upper manifold @21:04:05.80 Garaging FlushPuck in Collection Clamp @21:04:19.49 Starting stand-alone bac WCR @21:04:19.51 bac wcr sampling at most 520ml @21:04:19.56 Whole Cell Archive sampling 520ml @21:04:19.60 Loading wcr puck from tube 2 into Collection Clamp @21:04:38.04 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.57 @21:04:40.12 collectSample 520ml w/bubble point of 55psi @21:04:40.16 Priming 7ml @21:04:40.90 Calibrating pressure and temperature sensors @21:04:56.35 Waiting for external sampler to finish priming... @21:05:11.90 6.2L/min @21:05:41.98 6.2L/min @21:06:12.04 6.2L/min @21:06:42.11 6.2L/min @21:07:12.07 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @21:07:12.09 Retry #1 of 10 after 3:00 @21:07:12.17 6.1L/min @21:07:42.24 6.1L/min @21:07:53.74 Sampling 520.0ml @21:08:12.35 6.1L/min @21:08:42.41 6.1L/min @21:09:12.47 6.1L/min @21:09:42.54 6.1L/min @21:10:12.60 6.1L/min @21:10:42.70 6.1L/min @21:11:12.78 6.1L/min @21:11:26.59 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] @21:11:42.85 6.1L/min @21:12:12.92 6.1L/min @21:12:42.99 6.1L/min @21:13:13.06 6.1L/min @21:13:43.12 6.1L/min @21:14:13.18 6.1L/min @21:14:43.24 6.1L/min @21:15:13.31 6.1L/min @21:15:43.38 6.1L/min @21:16:13.44 6.1L/min @21:16:43.50 6.1L/min @21:17:13.56 6.1L/min @21:17:30.88 Sampled 520.0ml @21:17:30.95 Drying puck before fixing for 4:00 @21:17:37.79 CTD battery = 10.200V @21:18:53.70 Pumping wcr puck from tube 2 up to 55psi... @21:21:10.13 Fix #1 of 2 (with rnal) for 2:00 @21:21:10.64 Pulling 2ml of CSR.rnal @21:21:38.68 Pumping wcr puck from tube 2 up to 55psi... @21:25:10.93 Fix #2 of 2 (with rnal) for 2:00 @21:25:11.58 Pulling 2ml of CSR.rnal @21:25:39.55 Pumping wcr puck from tube 2 up to 55psi... @21:29:11.50 Storing wcr puck in Collection Clamp to tube 1 @21:29:40.65 Starting finalPurge @21:29:40.67 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @21:29:54.34 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.54 @21:29:56.37 Flushing the Collection Valve::Manifold @21:29:57.05 Pulling 5ml of CSR.flush @21:30:43.05 Flushing lower manifold's waste2b port @21:31:21.30 Disinfecting external Intake with kill @21:31:21.97 Pulling 7.999ml of CSR.kill @21:32:15.70 Pulling 5ml of CSR.flush @21:33:14.84 Garaging FlushPuck in Collection Clamp @21:33:28.24 Completed [at('9PM') {archive}] begun 21:00:19 @21:33:28.44 Asleep / Shutdown @21:33:29.01 Shutdown @21:33:29.06
Powering down until 09:30PST02-Feb-20 @21:33:59.18 Sending Email @21:35:48.33 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @21:35:48.35 Retry #1 of 10 after 3:00 @21:38:59.21 Email::Error in MAIN -- flush stuck! @09:29:25.19PST02-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @09:29:28.68 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @09:29:33.29 Polling Can every 10:00 @09:29:33.34 Cleanly exited at 21:33:29PST01-Feb-20 @09:29:33.79 Clients may connect on TCP port 9999 @09:29:33.80 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @09:29:34.15 Continuing goMexTank20jan from /home/esp/esp2/mission/long/goMexTank20jan.rb:17 @09:29:34.23 Waiting until 09:30 @09:30:00.06 Powering core bus @09:30:06.40 All dwarf controllers running firmware version 3.85 @09:30:19.82 Phase [at('9:30AM') {archive}] @09:30:19.84 Archive #5 on Sunday @09:30:19.86 Starting initialPurge @09:30:19.87 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @09:30:34.71 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.50 @09:30:36.61 Flushing the Collection Valve::Manifold @09:30:38.05 Pulling 5ml of CSR.flush @09:31:24.08 Purging external Intake @09:31:28.37 CTD battery = 10.200V @09:32:14.22
Flushing upper manifold @09:34:05.30 Garaging FlushPuck in Collection Clamp @09:34:19.05 Starting stand-alone bac WCR @09:34:19.07 bac wcr sampling at most 520ml @09:34:19.13 Whole Cell Archive sampling 520ml @09:34:19.34 Loading wcr puck from tube 2 into Collection Clamp @09:34:38.85 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.58 @09:34:40.86 collectSample 520ml w/bubble point of 55psi @09:34:40.90 Priming 7ml @09:34:41.55 Calibrating pressure and temperature sensors @09:34:56.73 Waiting for external sampler to finish priming... @09:35:12.39 6.2L/min @09:35:42.48 6.2L/min @09:36:12.54 6.2L/min @09:36:42.61 6.1L/min @09:36:57.59 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @09:36:57.61 Retry #1 of 10 after 3:00 @09:37:12.68 6.1L/min @09:37:42.74 6.1L/min @09:37:54.12 Sampling 520.0ml @09:38:12.80 6.1L/min @09:38:42.86 6.1L/min @09:39:12.92 6.1L/min @09:39:42.99 6.1L/min @09:40:13.16 6.1L/min @09:40:43.44 6.1L/min @09:41:13.53 6.1L/min @09:41:43.60 6.1L/min @09:42:13.67 6.1L/min @09:42:35.43 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @09:42:35.46 Retry #2 of 10 after 3:00 @09:42:43.74 6.1L/min @09:43:13.81 6.1L/min @09:43:43.87 6.1L/min @09:44:13.93 6.1L/min @09:44:43.99 6.1L/min @09:45:14.05 6.1L/min @09:45:44.12 6.1L/min @09:46:14.19 6.1L/min @09:46:44.26 6.1L/min @09:46:59.53 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] @09:47:14.33 6.1L/min @09:47:38.29 Sampled 520.0ml @09:47:38.33 Drying puck before fixing for 4:00 @09:47:45.19 CTD battery = 10.200V @09:49:00.77 Pumping wcr puck from tube 2 up to 55psi... @09:51:17.22 Fix #1 of 2 (with rnal) for 2:00 @09:51:17.76 Pulling 2ml of CSR.rnal @09:51:46.39 Pumping wcr puck from tube 2 up to 55psi... @09:55:18.22 Fix #2 of 2 (with rnal) for 2:00 @09:55:18.73 Pulling 2ml of CSR.rnal @09:55:46.77 Pumping wcr puck from tube 2 up to 55psi... @09:59:18.87 Storing wcr puck in Collection Clamp to tube 1 @09:59:47.97 Starting finalPurge @09:59:47.98 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @10:00:01.72 Collection Clamp onSpring/offSpring for 10/26 samples, on/off torque 1.55 @10:00:03.58 Flushing the Collection Valve::Manifold @10:00:04.28 Pulling 5ml of CSR.flush @10:00:50.46 Flushing lower manifold's waste2b port @10:01:28.65 Disinfecting external Intake with kill @10:01:30.03 Pulling 8ml of CSR.kill @10:02:24.31 Pulling 5ml of CSR.flush @10:03:23.49 Garaging FlushPuck in Collection Clamp @10:03:37.23 Completed [at('9:30AM') {archive}] begun 09:30:19 @10:03:37.42 Asleep / Shutdown @10:03:37.99 Shutdown @10:03:38.02
Powering down until 20:30 @10:04:08.09 Sending Email @10:05:12.21 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] @20:29:23.22PST02-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @20:29:26.74 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @20:29:31.28 Polling Can every 10:00 @20:29:31.34 Cleanly exited at 10:03:38PST02-Feb-20 @20:29:31.80 Clients may connect on TCP port 9999 @20:29:31.82 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @20:29:32.25 Continuing goMexTank20jan from /home/esp/esp2/mission/long/goMexTank20jan.rb:18 @20:29:32.33 Waiting until 20:30 @20:30:00.07 Powering core bus @20:30:06.44 All dwarf controllers running firmware version 3.85 @20:30:20.43 Phase [at('8:30PM') {archive}] @20:30:20.47 Archive #6 on Sunday @20:30:20.48 Starting initialPurge @20:30:20.49 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @20:30:35.30 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.56 @20:30:37.27 Flushing the Collection Valve::Manifold @20:30:38.71 Pulling 5ml of CSR.flush @20:31:25.14 Purging external Intake @20:31:26.88 CTD battery = 10.200V @20:32:15.67
Flushing upper manifold @20:34:06.52 Garaging FlushPuck in Collection Clamp @20:34:19.99 Starting stand-alone bac WCR @20:34:20.01 bac wcr sampling at most 520ml @20:34:20.06 Whole Cell Archive sampling 520ml @20:34:20.11 Loading wcr puck from tube 2 into Collection Clamp @20:34:39.46 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.57 @20:34:41.55 collectSample 520ml w/bubble point of 55psi @20:34:41.60 Priming 7ml @20:34:42.36 Calibrating pressure and temperature sensors @20:34:57.24 Waiting for external sampler to finish priming... @20:35:13.21 6.2L/min @20:35:43.30 6.2L/min @20:36:13.36 6.1L/min @20:36:43.45 6.1L/min @20:36:58.10 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @20:36:58.12 Retry #1 of 10 after 3:00 @20:37:13.52 6.1L/min @20:37:43.59 6.1L/min @20:37:55.03 Sampling 520.0ml @20:38:13.65 6.1L/min @20:38:43.71 6.1L/min @20:39:13.77 6.1L/min @20:39:43.84 6.1L/min @20:40:13.90 6.1L/min @20:40:43.97 6.1L/min @20:41:14.04 6.1L/min @20:41:44.10 6.1L/min @20:42:14.16 6.1L/min @20:42:44.23 6.1L/min @20:43:14.30 6.1L/min @20:43:22.90 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @20:43:22.92 Retry #2 of 10 after 3:00 @20:43:44.38 6.1L/min @20:44:14.55 6.1L/min @20:44:44.62 6.1L/min @20:45:14.68 6.1L/min @20:45:44.74 6.1L/min @20:46:14.81 6.1L/min @20:46:45.32 6.1L/min @20:47:15.44 6.1L/min @20:47:37.85 Sampled 520.0ml @20:47:37.90 Drying puck before fixing for 4:00 @20:47:44.77 CTD battery = 10.200V @20:49:00.62 Pumping wcr puck from tube 2 up to 55psi... @20:49:08.39 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @20:49:08.41 Retry #3 of 10 after 3:00 @20:51:17.66 Fix #1 of 2 (with rnal) for 2:00 @20:51:18.19 Pulling 2ml of CSR.rnal @20:51:46.46 Pumping wcr puck from tube 2 up to 55psi... @20:53:55.08 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] /usr/sbin/detachIridium: line 10: cannot open /dev/AT/iridium: Input/output error @20:54:01.34 Session Begun @20:54:01.39 -> Gate.cycleModemPower! 5 @20:54:01.44 Session Ended @20:55:18.94 Fix #2 of 2 (with rnal) for 2:00 @20:55:19.47 Pulling 2ml of CSR.rnal @20:55:47.62 Pumping wcr puck from tube 2 up to 55psi... @20:59:19.56 Storing wcr puck in Collection Clamp to tube 1 @20:59:48.05 Starting finalPurge @20:59:48.06 Loading FlushPuck into Collection Clamp from FlushPuck::Garage @21:00:01.95 Collection Clamp onSpring/offSpring for 9/26 samples, on/off torque 1.52 @21:00:03.85 Flushing the Collection Valve::Manifold @21:00:04.54 Pulling 5ml of CSR.flush @21:00:50.27 Flushing lower manifold's waste2b port @21:01:28.71 Disinfecting external Intake with kill @21:01:29.98 Pulling 8ml of CSR.kill @21:02:24.14 Pulling 5ml of CSR.flush @21:03:23.27 Garaging FlushPuck in Collection Clamp @21:03:36.95 Completed [at('8:30PM') {archive}] begun 20:30:20 @21:03:37.05 Asleep after completing goMexTank20jan assays @21:03:38.00 Shutdown @21:03:38.10
Asleep / Shutdown @21:03:38.16 Shutdown @21:03:38.24
Powering down indefinitely @21:04:08.29 Sending Email @21:05:24.83 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] @21:05:47.43 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] @08:27:38.05PST03-Feb-20
>RESET< ESP2 v3.41 I2C Gateway v3.20 for core bus @08:27:41.55 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @08:27:46.05 Polling Can every 10:00 @08:27:46.11 Cleanly exited at 21:03:38PST02-Feb-20 @08:27:46.55 Clients may connect on TCP port 9999 @08:27:46.59 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @08:27:47.03 MissionLog::Error in MAIN -- goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20 @08:27:47.06 Waiting to Resume from Checkpoint "goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20" @08:29:14.07 upsync rsync: safe_read failed to read 1 bytes [sender]: Connection reset by peer (104) rsync error: error in rsync protocol data stream (code 12) at io.c(276) [sender=3.1.3] @08:31:34.72 Session Begun @08:31:39.03 -> stayUp @08:31:46.47 -> exit @08:31:46.49 Session Ended @08:35:47.04
Resuming Thread after goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20 at 08:27:46 @08:36:17.08 Sending Email @08:38:33.42 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @08:38:33.44 Retry #1 of 10 after 3:00 @08:39:19.76 Session Begun @08:39:23.27 -> showlog @08:39:35.95 -> exit @08:39:35.96 Session Ended @08:40:03.94 Session Begun @08:40:32.86 -> Email.connectNetwork @08:41:17.12 Email::Error in MAIN -- flush stuck! @08:41:17.41 Session Ended @08:53:52.37PST03-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @08:53:56.01 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @08:54:00.59 Polling Can every 10:00 @08:54:00.65 Cleanly exited at 08:41:17PST03-Feb-20 @08:54:01.11 Clients may connect on TCP port 9999 @08:54:01.12 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @08:54:01.60 MissionLog::Error in MAIN -- goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20 @08:54:01.63 Waiting to Resume from Checkpoint "goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20" @08:57:54.90 Session Begun @08:57:57.86 -> stayUp @08:57:59.37 -> exit @08:57:59.39 Session Ended @08:58:41.90 upsync @08:59:28.59 Session Begun @08:59:32.82 -> stayUp false @08:59:56.38 -> ESP.shutdown @08:59:56.41 Shutdown @08:59:56.45 Asleep / Shutdown @09:00:02.42 -> ESP.powerdown @09:00:02.45 Shutdown @09:00:02.48 Asleep / Shutdown @09:00:02.55 Powering down indefinitely @09:00:32.61 Sending Email @09:01:42.49 upsync /usr/sbin/detachIridium: line 10: cannot open /dev/AT/iridium: Input/output error @09:01:48.81 Session Begun @09:01:48.86 -> Gate.cycleModemPower! 5 @09:01:48.92 Session Ended @11:00:03.81PST03-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @11:00:06.38 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @11:00:09.74 Polling Can every 10:00 @11:00:09.78 Cleanly exited at 09:00:02PST03-Feb-20 @11:00:10.16 Clients may connect on TCP port 9999 @11:00:10.17 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @11:00:10.50 MissionLog::Error in MAIN -- goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20 @11:00:10.52 Waiting to Resume from Checkpoint "goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20" @11:01:49.53 upsync @11:07:34.14PST03-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @11:07:37.65 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @11:07:42.18 Polling Can every 10:00 @11:07:42.24 Cleanly exited at 11:00:09PST03-Feb-20 @11:07:42.70 Clients may connect on TCP port 9999 @11:07:42.71 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @11:07:43.20 MissionLog::Error in MAIN -- goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20 @11:07:43.23 Waiting to Resume from Checkpoint "goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20" @11:09:09.08 Session Begun @11:09:16.15 -> stayUp @11:09:20.95 -> MainThread.exit @11:09:46.21 upsync @11:09:47.06 Session Ended @11:13:33.97PST03-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @11:13:37.47 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @11:13:42.30 Polling Can every 10:00 @11:13:42.37 Cleanly exited at 11:12:57PST03-Feb-20 @11:13:42.42 Waiting for espclients... @11:13:42.65 Session Begun @11:13:42.70 -> ESP.powerdown @11:13:42.74 Shutdown @11:13:42.76 Asleep / Shutdown @11:13:42.80 Powering down indefinitely @11:13:46.56 upsync @11:33:18.60PST03-Feb-20
>RESET< ESP2 v3.41 I2C Gateway v3.20 for core bus @11:33:22.31 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @11:33:26.88 Polling Can every 10:00 @11:33:26.95 Cleanly exited at 11:13:42PST03-Feb-20 @11:33:27.40 Clients may connect on TCP port 9999 @11:33:27.43 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @11:33:27.89 MissionLog::Error in MAIN -- goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20 @11:33:27.93 Waiting to Resume from Checkpoint "goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20" @11:33:58.21 Session Begun @11:33:58.24 -> ESP.powerdown @11:33:58.29 Shutdown @11:33:58.32 Asleep / Shutdown @11:33:58.35 Powering down indefinitely @11:34:28.37 Sending Email @11:34:29.63 Session Begun @11:34:39.87 -> exit @11:34:40.28 Session Ended @11:34:59.33 Session Begun @11:34:59.36 -> ESP.powerdown @11:34:59.41 Shutdown @11:34:59.44 Asleep / Shutdown @11:34:59.47 Powering down indefinitely @11:35:29.50 Sending Email @11:35:56.12 Session Begun @11:36:07.83 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @11:36:07.86 Retry #1 of 10 after 3:00 @11:36:24.33 -> list ESP.method :pWrOffNOW! @11:36:43.87 -> quit @11:36:43.88 Session Ended @11:36:59.55 Session Begun @11:36:59.58 -> ESP.pWrOffNOW! false @11:36:59.62 Shutdown @11:36:59.65 Asleep / Shutdown @11:36:59.68 Powering down indefinitely @11:37:29.71 Sending Email @11:37:39.34 Session Begun @11:37:45.97 -> MainThread.exit @11:37:48.44 -> MainThread.exit @11:37:48.46
Sending Email @11:37:51.51 -> MainThread.exit @11:37:51.53 Email::Error in MAIN -- flush stuck! @11:37:51.62 Session Ended @11:37:51.65 Session Ended @11:37:51.69 Session Ended @11:37:51.72 Session Ended @11:38:15.37PST03-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @11:38:18.91 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @11:38:23.18 Polling Can every 10:00 @11:38:23.25 Cleanly exited at 11:37:51PST03-Feb-20 @11:38:23.30 Waiting for espclients... @11:38:28.69 Session Begun @11:38:28.73 -> ESP.pWrOffNOW! false @11:38:28.76 Shutdown @11:38:28.79 Asleep / Shutdown @11:38:28.82 Powering down indefinitely @13:44:34.76PST03-Feb-20
ESP2 v3.41 I2C Gateway v3.20 for core bus @13:44:37.30 Configuration for moe 10/23/19 by maro@mbari.org /home/esp/esp2/type/shallow/moe/configure.rb @13:44:40.55 Polling Can every 10:00 @13:44:40.61 Cleanly exited at 11:38:28PST03-Feb-20 @13:44:40.98 Clients may connect on TCP port 9999 @13:44:40.99 Loading /home/esp/esp2/mission/long/goMexTank20jan.rb mission @13:44:41.32 MissionLog::Error in MAIN -- goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20 @13:44:41.34 Waiting to Resume from Checkpoint "goMexTank20jan mission ended at 21:03:36.96PST02-Feb-20" @13:46:07.98 Session Begun @13:46:12.17 -> stayUp @13:46:35.31 -> MainThread.exit @13:46:57.85 SocketError in Qmail -- getaddrinfo: Temporary failure in name resolution @13:46:57.88 Retry #1 of 10 after 3:00 @13:47:05.35
Sending Email @13:52:05.36 Email::Error in MAIN -- flush stuck! @13:52:05.42 Session Ended