@17:12:56.71PDT03-Apr-23
>BREAK< ESP3 Gateway v1.12 for core bus @17:12:56.74 >BREAK< ESP3 Gateway v1.12 for cartridge bus @17:12:59.98 Configuration for mv3 11/14/22 by preston@mbari.org /home/esp/esp2/type/auv/mv3/configure.rb @17:13:00.45 Sea pressure (Abs) tare is 9% of full scale @17:13:02.60 Polling Can every 2:00 @17:13:02.65 Waiting for espclients... @17:13:15.50 Session Begun @17:13:31.54 -> slots {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 34..30 => { Type: :archiveNull_bac, State: :dry}, [36,35] => { Type: :archive_bac, State: :dry}} @17:13:46.14 -> Cmd.loadCartridge @17:13:46.34 Gate.power :analytic1,:ON,limit to 5000mA @17:13:46.36 Gate.power :analytic2,:ON,limit to 5000mA @17:13:46.40 Gate.power :analytic3,:ON,limit to 5000mA @17:13:46.80 Archive.configure :default @17:13:47.27 Archive.hold @17:13:47.41 Archive.configure :default @17:13:47.60 Air.configure :default @17:13:47.70 Air.hold @17:13:47.80 Air.configure :default @17:13:47.96 Lysis1.configure :default @17:13:48.06 Lysis1.hold @17:13:48.17 Lysis1.configure :default @17:13:48.33 Lysis2.configure :default @17:13:48.43 Lysis2.hold @17:13:48.54 Lysis2.configure :default @17:13:48.72 Plunge.configure :default @17:13:48.82 Plunge.hold @17:13:48.92 Plunge.configure :default @17:13:49.12 SamplePump.configure :default @17:13:49.35 Toroid.configure :default @17:13:49.45 Toroid.hold @17:13:49.55 Toroid.configure :default @17:13:49.74 Carousel.configure :default @17:13:49.84 Carousel.hold @17:13:49.95 Carousel.configure :default @17:13:50.14 Pressure.configure :default @17:13:50.32 ExtraPump.configure :default @17:13:50.42 All elf controllers running firmware version 4.794 @17:13:51.12 Toroid.seek :clear @17:13:51.28 Carousel.in :default @17:13:51.45 Carousel.home.seek 56 @17:13:51.74 Selecting Cartridge 36 @17:13:52.01 Carousel.seek 36 @17:13:56.93 Lysis1.in :fast @17:13:57.02 Lysis1.seek :locked @17:13:59.32 Plunge.seek :locked @17:13:59.50 Air.in :fast @17:13:59.60 Air.seek :locked @17:14:01.20 Carousel.reconfigure :locked @17:14:01.31 Carousel.jog 0 @17:14:02.02 Mounted archive Cartridge 36 @17:14:16.00 -> Cmd.filter 150 @17:14:16.39 Preparing to filter cartridge 36 @17:14:16.74 Priming sample loop w/100ml, bypass w/10ml @17:14:16.77 SamplePump.setPosition! 0ml @17:14:16.87 Exhaust.close @17:14:16.98 Bypass.open @17:14:18.49 Intake.open @17:14:19.26 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @17:14:21.85 Vacuum tare is 18% of full scale @17:14:22.04 Sea pressure (Abs) tare is 10% of full scale @17:14:22.23 Pressure.in :default @17:14:22.33 Pressure.hold @17:14:22.58 SamplePump.in :prime @17:14:22.69 SamplePump.seek 10ml,59 seconds @17:14:32.21 Pressure.stop @17:14:32.33 SamplePump.setPosition! 0ml @17:14:32.44 Intake.close @17:14:32.52 Bypass.close @17:14:33.30 Cmd::Paused in FILTERING -- paused by brent while setting Sample Pump (SP)'s position after sampling 0.0ml @17:14:33.34 UserAbort in brent -- User Abort!! @17:14:52.08 -> Cart.sampler.primeVol=30 @17:14:52.10 NoMethodError in brent -- undefined method `primeVol=' for BACsampler:Cartridge::Sampler @17:15:02.10 -> Cart.sampler BACsampler @17:15:06.53 -> Cart.sampler.examine @17:15:10.26 -> Cart.sampler.primeVolume=30 30 @17:15:15.62 -> Cmd.filter 150 @17:15:15.97 Preparing to filter cartridge 36 @17:15:16.31 Priming sample loop w/30ml, bypass w/10ml @17:15:16.33 SamplePump.setPosition! 0ml @17:15:16.42 Bypass.open @17:15:17.80 Intake.open @17:15:18.56 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @17:15:21.18 Vacuum tare is 18% of full scale @17:15:21.38 Sea pressure (Abs) tare is 10% of full scale @17:15:21.57 Pressure.in :default @17:15:21.66 Pressure.hold @17:15:21.92 SamplePump.in :prime @17:15:22.02 SamplePump.seek 10ml,59 seconds @17:15:31.58 Pressure.stop @17:15:31.67 SamplePump.setPosition! 0ml @17:15:31.76 Exhaust.open @17:15:33.10 Bypass.close @17:15:34.62 Pressure.in :default @17:15:34.72 Pressure.hold @17:15:35.62 SamplePump.in :prime @17:15:35.72 SamplePump.seek 30ml,1:56 @17:16:03.48 Pressure.stop @17:16:03.59 Bypass.open @17:16:04.20 Intake.close @17:16:04.97 Toroid.in :hold @17:16:05.07 Toroid.seek :crack @17:16:06.64 Toroid.seek :cartridge @17:16:07.62 Toroid.in :default @17:16:07.73 Toroid.seek :clear @17:16:09.76 Pressurizing cartridge to 26psi above 14.7psia @17:16:09.79 SamplePump.setPosition! 0ml @17:16:09.88 Intake.open @17:16:10.53 Bypass.close @17:16:11.21 Exhaust.close @17:16:12.05 Pressure.in :default @17:16:12.15 Pressure.hold @17:16:12.40 SamplePump.in :charge @17:16:12.51 SamplePump.seek 2.3ml,42 seconds @17:16:27.13 Pressure.stop @17:16:27.25 Intake.close @17:16:28.03 Pressurized cartridge with 1.037ml to 26.2psi @17:16:28.04 Isolated @40.2psia (25.5psi) @17:16:28.08 Verifying cartridge holds at least 0.65..0.85 of 40.2psia @17:16:28.14 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @17:16:32.90 Sampling 150.0ml in 1:25:20 @17:16:32.92 SamplePump.setPosition! 0ml @17:16:33.02 Exhaust.open @17:16:33.64 Intake.open @17:16:34.52 Pressure.in :default @17:16:34.61 Pressure.hold @17:16:35.00 SamplePump.in :sample @17:16:35.65 SamplePump.seek 150ml,13:00 @17:16:37.51 Cartridge 36 filtering 1/150ml at 0.66ml/s with 23.8psi vacuum @17:17:37.52 Cartridge 36 filtering 37/150ml at 0.63ml/s with 31.6psi vacuum @17:18:37.52 Cartridge 36 filtering 72/150ml at 0.57ml/s with 17.7psi vacuum @17:19:37.52 Cartridge 36 filtering 108/150ml at 0.56ml/s with 24.5psi vacuum @17:20:37.52 Cartridge 36 filtering 143/150ml at 0.56ml/s with 24.3psi vacuum @17:20:49.21 Pressure.stop @17:20:49.50 Intake.close @17:20:49.55 Exhaust.close @17:20:49.84 Toroid.in :hold @17:20:49.94 Toroid.seek :bypass @17:20:51.60 Toroid.in :default @17:20:51.69 Toroid.seek :clear @17:20:53.35 Sampled 150.0ml :PAUSED @17:22:49.95 -> Cmd.process @17:22:50.54 Plunge.seek :reagent @17:22:51.47 Sample loop closed. Ready to Deliver Reagents @17:22:51.50 Archive.seek :sealed @17:22:55.22 Archive.seek :evac @17:23:09.06 Slide::Error in PROCESSING -- Archive Syringe (ArS) positionErr at 5uL (sensed 32uL) @17:23:09.09 Retry #1 of 2 @17:23:09.14 Archive.hold @17:23:09.37 Archive.in :default @17:23:09.49 Archive.home.seek :evac @17:23:10.18 Slide::Error in PROCESSING -- Archive Syringe (ArS) positionErr at 4uL (sensed 31uL) @17:23:10.20 Retry #2 of 2 @17:23:10.25 Archive.in :default @17:23:10.39 Archive.hold @17:23:10.53 Archive.in :default @17:23:10.64 Archive.home.seek :evac @17:23:11.30 Slide::Error in PROCESSING -- IGNORED Archive Syringe (ArS) positionErr at 5uL (sensed 31uL) @17:23:11.33 Archive.in :default @17:23:11.46 Archive.hold @17:23:11.59 Archive.in :default @17:23:11.69 Archive.home.jog 0 @17:23:11.82 delay 1:00 @17:24:11.85 Archive.seek :clear @17:24:28.74 RNAlater soak for 10:00 @17:34:28.77 Archive.seek :tVent @17:34:30.46 delay 1 second @17:34:31.49 Archive.seek :evac @17:34:47.40 Slide::Error in PROCESSING -- Archive Syringe (ArS) positionErr at 1uL (sensed 26uL) @17:34:47.42 Retry #1 of 2 @17:34:47.46 Archive.hold @17:34:47.64 Archive.in :default @17:34:47.75 Archive.home.seek :evac @17:34:48.47 Slide::Error in PROCESSING -- Archive Syringe (ArS) positionErr at 1uL (sensed 26uL) @17:34:48.49 Retry #2 of 2 @17:34:48.58 Archive.in :default @17:34:48.68 Archive.hold @17:34:48.82 Archive.in :default @17:34:48.93 Archive.home.seek :evac @17:34:49.64 Slide::Error in PROCESSING -- IGNORED Archive Syringe (ArS) positionErr at 1uL (sensed 26uL) @17:34:49.67 Archive.in :default @17:34:49.81 Archive.hold @17:34:49.94 Archive.in :default @17:34:50.04 Archive.home.jog 0 @17:34:50.19 delay 10 seconds @17:35:00.23 Sample preserved and evacuated :PROCESSED @18:35:09.30 -> exit @18:35:09.32 Session Ended @21:29:13.13 Session Begun @21:29:17.66 -> client ESP["brent"] @21:29:42.55 -> exit @21:29:42.57 Session Ended @21:29:54.86 Session Begun @21:29:58.42 -> slots {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 34..30 => { Type: :archiveNull_bac, State: :dry}, 35 => { Type: :archive_bac, State: :dry}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @21:30:54.29 -> BACsampler.goalVolume 1000 @21:30:59.70 -> BACsampler.goalVolume=134 134 @21:31:08.01 -> BACsampler.primeVolume 30 @21:31:23.06 -> Cmd.runCartridge @21:31:23.12 Selecting Cartridge 35 @21:31:23.35 Carousel.in :default @21:31:23.51 Carousel.home.seek 36 @21:31:23.90 Archive.in :unlocking @21:31:24.08 Archive.seek :clear @21:31:24.19 Air.in :unlocking @21:31:24.41 Air.seek :clear @21:31:26.47 Slide::Error in brent -- Archive Syringe (ArS) positionErr at 919uL (sensed 895uL) @21:31:39.17 -> stop Archive = Archive Syringe (ArS) Not yet Homed! Air = Air Syringe (AirS) clear Lysis1 = Lysis Syringe #1 (LyS1) locked Lysis2 = Lysis Syringe #2 (LyS2) clear Plunge = Plunge Valve (PV) at reagentLG Handoff Valve::Manifold selects blocked SamplePump = Sample Pump (SP) at 150ml Intake is closed Exhaust is closed Bypass = Bypass (PB) is closed Toroid = Toroid Valve (TV) clear Carousel = Storage Carousel (SC) at 36 Pressure = Absolute Pressure (Leak) Sensor @16.0psia Toxicant = External Toxicant Valve::Manifold selects exhaust @21:31:42.35 -> Cmd.runCartridge @21:31:42.54 Archive.in :default @21:31:43.03 Archive.home.jog 0 @21:31:43.40 Archive.in :homing @21:31:43.49 Archive.jog 4471 @21:31:46.11 Archive.setRawPosition! 50 @21:31:46.18 Archive.seek :home @21:31:46.49 Archive.in :default @21:31:46.86 Toroid.seek :clear @21:31:46.97 Carousel.in :default @21:31:47.13 Carousel.home.seek 36 @21:31:47.62 Selecting Cartridge 34 @21:31:48.23 Carousel.in :default @21:31:48.40 Carousel.home.seek 36 @21:31:49.59 Lysis1.in :unlocking @21:31:49.77 Lysis1.seek :clear @21:31:49.85 Plunge.in :unlocking @21:31:50.02 Plunge.seek :clear @21:31:51.26 Carousel.seek 34 @21:31:52.51 Lysis1.in :fast @21:31:52.61 Lysis1.seek :locked @21:31:54.90 Plunge.in :default @21:31:55.06 Plunge.seek :locked @21:31:55.23 Air.in :fast @21:31:55.32 Air.seek :locked @21:31:56.89 Carousel.reconfigure :locked @21:31:57.00 Carousel.jog 0 @21:31:57.73 Mounted archive Cartridge @21:31:58.10 Preparing to filter cartridge 34 @21:31:58.45 Priming sample loop w/30ml, bypass w/10ml @21:31:58.47 SamplePump.setPosition! 0ml @21:31:58.58 Bypass.open @21:31:59.98 Intake.open @21:32:00.70 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @21:32:03.30 Vacuum tare is 19% of full scale @21:32:03.59 Sea pressure (Abs) tare is 10% of full scale @21:32:03.77 Pressure.in :default @21:32:03.87 Pressure.hold @21:32:04.12 SamplePump.in :prime @21:32:04.22 SamplePump.seek 10ml,59 seconds @21:32:13.78 Pressure.stop @21:32:13.86 SamplePump.setPosition! 0ml @21:32:13.95 Exhaust.open @21:32:15.29 Bypass.close @21:32:16.84 Pressure.in :default @21:32:16.92 Pressure.hold @21:32:17.84 SamplePump.in :prime @21:32:17.94 SamplePump.seek 30ml,1:56 @21:32:46.39 Pressure.stop @21:32:46.51 Bypass.open @21:32:47.11 Intake.close @21:32:47.85 Toroid.in :hold @21:32:47.95 Toroid.seek :crack @21:32:49.52 Toroid.seek :cartridge @21:32:50.50 Toroid.in :default @21:32:50.59 Toroid.seek :clear @21:32:52.59 Pressurizing cartridge to 26psi above 14.1psia @21:32:52.60 SamplePump.setPosition! 0ml @21:32:52.70 Intake.open @21:32:53.35 Bypass.close @21:32:53.97 Exhaust.close @21:32:54.82 Pressure.in :default @21:32:54.91 Pressure.hold @21:32:55.20 SamplePump.in :charge @21:32:55.30 SamplePump.seek 2.3ml,42 seconds @21:33:03.69 Pressure.stop @21:33:03.79 Intake.close @21:33:04.60 Pressurized cartridge with 0.337ml to 26.3psi @21:33:04.61 Isolated @38.6psia (24.5psi) @21:33:04.65 Verifying cartridge holds at least 0.65..0.85 of 38.6psia @21:33:04.72 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @21:33:09.49 Sampling 134.0ml in 13:10 @21:33:09.51 SamplePump.setPosition! 0ml @21:33:09.61 Exhaust.open @21:33:10.26 Intake.open @21:33:11.18 Pressure.in :default @21:33:11.29 Pressure.hold @21:33:12.20 SamplePump.in :sample @21:33:12.30 SamplePump.seek 134ml,11:40 @21:33:14.14 Cartridge 34 filtering 1/134ml at 0.78ml/s with 17.5psi vacuum 13.9m deep (35.2psia) @21:34:14.15 Cartridge 34 filtering 42/134ml at 0.65ml/s with 19.7psi vacuum @21:35:14.14 Cartridge 34 filtering 83/134ml at 0.70ml/s with 10.4psi vacuum 2.4m deep (18.2psia) @21:36:14.15 Cartridge 34 filtering 124/134ml at 0.64ml/s with 42.7psi vacuum @21:36:28.19 Pressure.stop @21:36:28.36 Intake.close @21:36:28.41 Exhaust.close @21:36:28.73 Toroid.in :hold @21:36:28.83 Toroid.seek :bypass @21:36:30.49 Toroid.in :default @21:36:30.58 Toroid.seek :clear @21:36:32.23 Sampled 134.0ml @21:36:32.89 Plunge.seek :reagent @21:36:33.82 Sample loop closed. Ready to Deliver Reagents @21:36:34.06 Carousel.in :default @21:36:34.22 Carousel.home.seek 34 @21:36:34.60 Plunge.seek :locked @21:36:35.69 Air.in :unlocking @21:36:35.87 Air.seek :clear @21:36:35.93 Lysis1.in :unlocking @21:36:36.16 Lysis1.seek :clear @21:36:37.96 Gate.power :motor,:OFF @21:36:37.98 Gate.power :core,:OFF @21:36:38.01 Gate.power :analytic1,:OFF @21:36:38.04 Gate.power :analytic2,:OFF @21:36:38.10 Gate.power :analytic3,:OFF @21:36:38.14 Gate.power :main,:OFF @21:36:38.18 Safely stopped and ready to power off :STOPPED @21:37:27.42 -> Cmd.status {state: :STOPPED} @21:38:58.84 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 33..30 => { Type: :archiveNull_bac, State: :dry}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @21:39:58.46 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 33..30 => { Type: :archiveNull_bac, State: :dry}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @21:43:43.63 -> BACsampler.examine @21:54:43.28 -> stop Archive = core bus was not powered while reading Archive Syringe (ArS)'s status Air = core bus was not powered while reading Air Syringe (AirS)'s status Lysis1 = core bus was not powered while reading Lysis Syringe #1 (LyS1)'s status Lysis2 = core bus was not powered while reading Lysis Syringe #2 (LyS2)'s status Plunge = core bus was not powered while reading Plunge Valve (PV)'s status Handoff Valve::Manifold selects blocked SamplePump = core bus was not powered while reading Sample Pump (SP)'s status Intake is closed Exhaust is closed Bypass = Bypass (PB) is closed Toroid = core bus was not powered while reading Toroid Valve (TV)'s status Carousel = core bus was not powered while reading Storage Carousel (SC)'s status Pressure = core bus was not powered while reading Absolute Pressure (Leak) Sensor's status Toxicant = External Toxicant Valve::Manifold selects exhaust @21:58:12.23 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 33..30 => { Type: :archiveNull_bac, State: :dry}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:04:18.74 -> reload Cmd [/home/esp/esp2/utils/auv/cmd.rb] @22:04:49.52 -> fire :five, :three @22:04:49.54 NoMethodError in brent -- undefined method `fire' for CmdServer::Client:Class @22:04:57.73 -> Cmd.fire :five, :tree @22:04:57.79 Gate.power :main,:ON,limit to 5000mA @22:04:57.82 Gate.power :analytic1,:ON,limit to 5000mA @22:04:57.87 Gate.power :analytic2,:ON,limit to 5000mA @22:04:57.91 Gate.power :analytic3,:ON,limit to 5000mA @22:04:58.03 Powering core bus @22:05:02.41 Archive.configure :default @22:05:02.54 Air.configure :default @22:05:02.64 Lysis1.configure :default @22:05:02.74 Lysis2.configure :default @22:05:02.89 Plunge.configure :default @22:05:03.02 SamplePump.configure :default @22:05:03.16 Toroid.configure :default @22:05:03.32 Carousel.configure :default @22:05:03.45 Pressure.configure :default @22:05:03.57 ExtraPump.configure :default @22:05:03.67 All elf controllers running firmware version 4.794 @22:05:03.70 Gate.power :motor,:ON,limit to 5000mA @22:05:04.17 Archive.home.jog 0 @22:05:04.67 Toroid.home.jog 0 @22:05:04.72 Plunge.home.jog 0 @22:05:04.77 Lysis1.home.jog 0 @22:05:04.84 Air.home.jog 0 @22:05:04.90 Carousel.home.jog 0 @22:05:04.95 Lysis2.home.jog 0 @22:05:05.67 Archive.in :homing @22:05:05.91 Archive.jog 1365 @22:05:05.98 Plunge.in :homing @22:05:06.04 Lysis1.in :homing @22:05:06.08 Toroid.in :homing @22:05:06.15 Air.in :homing @22:05:06.23 Lysis2.in :homing @22:05:06.54 Lysis1.jog 1339 @22:05:06.57 Plunge.jog 820 @22:05:06.64 Toroid.jog 602 @22:05:06.72 Air.jog 1363 @22:05:06.82 Lysis2.jog 1362 @22:05:07.44 Archive.setRawPosition! 50 @22:05:07.53 Archive.seek :home @22:05:07.79 Plunge.setRawPosition! 50 @22:05:07.90 Archive.in :default @22:05:07.93 Plunge.seek :home @22:05:08.16 Lysis2.setRawPosition! 50 @22:05:08.19 Lysis1.setRawPosition! 50 @22:05:08.23 Air.setRawPosition! 50 @22:05:08.41 Lysis2.seek :home @22:05:08.47 Lysis1.seek :home @22:05:08.51 Air.seek :home @22:05:08.82 Plunge.in :default @22:05:08.98 Lysis2.in :default @22:05:09.01 Air.in :default @22:05:09.24 Toroid.setRawPosition! 0 @22:05:09.27 Lysis1.in :default @22:05:09.41 Toroid.seek :home @22:05:09.57 Toroid.in :default @22:05:09.72 Toroid.seek :clear @22:05:11.34 Carousel.in :default @22:05:11.51 Carousel.home.seek 34 @22:05:11.88 Selecting Cartridge 33 @22:05:12.16 Carousel.seek 33 @22:05:13.72 Lysis1.in :fast @22:05:13.82 Lysis1.seek :locked @22:05:16.10 Plunge.seek :locked @22:05:16.30 Air.in :fast @22:05:16.39 Air.seek :locked @22:05:17.97 Carousel.reconfigure :locked @22:05:18.08 Carousel.jog 0 @22:05:18.79 Mounted archive Cartridge @22:05:19.21 Preparing to filter cartridge 33 @22:05:19.56 Priming sample loop w/30ml, bypass w/10ml @22:05:19.59 SamplePump.setPosition! 0ml @22:05:19.68 Bypass.open @22:05:21.08 Intake.open @22:05:21.83 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @22:05:23.55 Intake.close @22:05:23.65 Bypass.close @22:05:24.44 Cmd::Paused in FILTERING -- paused by brent after sampling 0.0ml @22:05:24.48 UserAbort in brent -- User Abort!! @22:05:30.18 -> slots {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 33..30 => { Type: :archiveNull_bac, State: :dry}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:05:53.22 -> Cmd.loadCartridge :five @22:05:53.27 Cartridge::TypeUnknown in brent -- :five is not aRNAl_bac, aRNAl_phyto, aRNAl_zoo, archiveHiBiomass_bac, archiveNull_bac, archive_bac, archive_phyto, archive_zoo, daSPR_bac, daSPR_phyto, daSPR_phyto9, daSPR_zoo, lyseHold_bac, lyseHold_phyto, lyseHold_zoo, lyseNull_bac, microSPR_bac, microSPR_phyto, microSPR_zoo or unknown @22:06:43.43 -> Cmd.stop @22:06:43.57 Carousel.in :default @22:06:43.74 Carousel.home.seek 33 @22:06:44.09 Plunge.seek :locked @22:06:44.37 Air.in :unlocking @22:06:44.55 Air.seek :clear @22:06:44.66 Lysis1.in :unlocking @22:06:44.85 Lysis1.seek :clear @22:06:46.63 Gate.power :motor,:OFF @22:06:46.65 Gate.power :core,:OFF @22:06:46.69 Gate.power :analytic1,:OFF @22:06:46.73 Gate.power :analytic2,:OFF @22:06:46.78 Gate.power :analytic3,:OFF @22:06:46.82 Gate.power :main,:OFF @22:06:46.87 Safely stopped and ready to power off :STOPPED @22:06:51.89 -> Cmd.loadCartridge :five @22:06:51.92 Cartridge::TypeUnknown in brent -- :five is not aRNAl_bac, aRNAl_phyto, aRNAl_zoo, archiveHiBiomass_bac, archiveNull_bac, archive_bac, archive_phyto, archive_zoo, daSPR_bac, daSPR_phyto, daSPR_phyto9, daSPR_zoo, lyseHold_bac, lyseHold_phyto, lyseHold_zoo, lyseNull_bac, microSPR_bac, microSPR_phyto, microSPR_zoo or unknown @22:06:56.46 -> Cmd.fire :five, :tree @22:06:56.53 Gate.power :main,:ON,limit to 5000mA @22:06:56.56 Gate.power :analytic1,:ON,limit to 5000mA @22:06:56.62 Gate.power :analytic2,:ON,limit to 5000mA @22:06:56.66 Gate.power :analytic3,:ON,limit to 5000mA @22:06:56.76 Powering core bus @22:06:59.61 Archive.configure :default @22:06:59.74 Air.configure :default @22:07:00.39 Lysis1.configure :default @22:07:00.49 Lysis2.configure :default @22:07:00.62 Plunge.configure :default @22:07:00.75 SamplePump.configure :default @22:07:00.87 Toroid.configure :default @22:07:01.00 Carousel.configure :default @22:07:01.13 Pressure.configure :default @22:07:01.29 ExtraPump.configure :default @22:07:01.39 All elf controllers running firmware version 4.79 @22:07:01.42 Gate.power :motor,:ON,limit to 5000mA @22:07:01.80 Archive.home.jog 0 @22:07:02.38 Carousel.home.jog 0 @22:07:02.42 Toroid.home.jog 0 @22:07:02.49 Lysis2.home.jog 0 @22:07:02.56 Lysis1.home.jog 0 @22:07:02.60 Air.home.jog 0 @22:07:02.65 Plunge.home.jog 0 @22:07:03.38 Archive.in :homing @22:07:03.66 Archive.jog 1360 @22:07:03.73 Plunge.in :homing @22:07:03.79 Lysis1.in :homing @22:07:03.83 Toroid.in :homing @22:07:03.92 Air.in :homing @22:07:04.00 Lysis2.in :homing @22:07:04.42 UserAbort in brent -- User Abort!! @22:07:04.58 Toroid.jog 608 @22:07:04.63 Lysis1.jog 1346 @22:07:04.69 Plunge.jog 810 @22:07:04.73 Air.jog 1361 @22:07:04.79 Lysis2.jog 1363 @22:07:05.36 Archive.setRawPosition! 50 @22:07:05.44 Archive.seek :home @22:07:05.76 Archive.in :default @22:07:05.88 Plunge.setRawPosition! 50 @22:07:05.96 Plunge.seek :home @22:07:06.08 Lysis1.setRawPosition! 50 @22:07:06.17 Lysis1.seek :home @22:07:06.32 Plunge.in :default @22:07:06.34 Lysis2.setRawPosition! 50 @22:07:06.38 Air.setRawPosition! 50 @22:07:06.59 Lysis2.seek :home @22:07:06.64 Air.seek :home @22:07:06.86 Lysis1.in :default @22:07:06.99 Toroid.setRawPosition! 0 @22:07:07.08 Toroid.seek :home @22:07:07.25 Lysis2.in :default @22:07:07.28 Air.in :default @22:07:07.32 Toroid.in :default @22:07:12.97 -> Cmd.stop @22:07:13.63 Carousel.in :default @22:07:13.79 Carousel.home.seek 33 @22:07:14.31 Lysis1.in :fast @22:07:14.41 Lysis1.seek :locked @22:07:16.59 Plunge.seek :locked @22:07:18.19 Lysis1.in :unlocking @22:07:18.38 Lysis1.seek :clear @22:07:20.16 Gate.power :motor,:OFF @22:07:20.18 Gate.power :core,:OFF @22:07:20.23 Gate.power :analytic1,:OFF @22:07:20.26 Gate.power :analytic2,:OFF @22:07:20.30 Gate.power :analytic3,:OFF @22:07:20.33 Gate.power :main,:OFF @22:07:20.37 Safely stopped and ready to power off :STOPPED @22:07:37.63 -> cart :cart @22:07:50.94 -> Cmd.runCartridge :five @22:07:50.99 Cartridge::TypeUnknown in brent -- :five is not aRNAl_bac, aRNAl_phyto, aRNAl_zoo, archiveHiBiomass_bac, archiveNull_bac, archive_bac, archive_phyto, archive_zoo, daSPR_bac, daSPR_phyto, daSPR_phyto9, daSPR_zoo, lyseHold_bac, lyseHold_phyto, lyseHold_zoo, lyseNull_bac, microSPR_bac, microSPR_phyto, microSPR_zoo or unknown @22:09:28.29 -> list Cmd.method :runCarts def runCarts *carts #run specified list of cartridges back to back #Each cartridge specified as a slot number or next slot of a Cartridge.type #nil may be specified as a placeholder for the next cartridge of *any* type #More complex criteria may not be specified. #Goal volumes, etc. are changed by altering the cartridge's Sampler object #stops after last cartridge on list is completed carts.each{|cart| runCartridge cart} end def fire *carts runCarts *carts stop end def mountCartridge *args, &criteria loadCartridge *args, &criteria end def loadCartridge slotOrType=nil, goalState=nil, &givenCriteria #load specified slot number or next of type in goalState @22:09:40.58 -> reload Cmd [/home/esp/esp2/utils/auv/cmd.rb] @22:09:58.83 -> Cmd.runCarts :five @22:09:58.87 Cartridge::TypeUnknown in brent -- :five is not aRNAl_bac, aRNAl_phyto, aRNAl_zoo, archiveHiBiomass_bac, archiveNull_bac, archive_bac, archive_phyto, archive_zoo, daSPR_bac, daSPR_phyto, daSPR_phyto9, daSPR_zoo, lyseHold_bac, lyseHold_phyto, lyseHold_zoo, lyseNull_bac, microSPR_bac, microSPR_phyto, microSPR_zoo or unknown @22:10:35.17 -> Cmd.fire :five, :four @22:10:35.27 Cartridge::TypeUnknown in brent -- :five is not aRNAl_bac, aRNAl_phyto, aRNAl_zoo, archiveHiBiomass_bac, archiveNull_bac, archive_bac, archive_phyto, archive_zoo, daSPR_bac, daSPR_phyto, daSPR_phyto9, daSPR_zoo, lyseHold_bac, lyseHold_phyto, lyseHold_zoo, lyseNull_bac, microSPR_bac, microSPR_phyto, microSPR_zoo or unknown @22:10:49.25 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 33..30 => { Type: :archiveNull_bac, State: :dry}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:11:15.91 -> Cmd.fire nil, :archiveNull_bac @22:11:15.99 Gate.power :main,:ON,limit to 5000mA @22:11:16.01 Gate.power :analytic1,:ON,limit to 5000mA @22:11:16.05 Gate.power :analytic2,:ON,limit to 5000mA @22:11:16.08 Gate.power :analytic3,:ON,limit to 5000mA @22:11:16.20 Powering core bus @22:11:20.05 Archive.configure :default @22:11:20.18 Air.configure :default @22:11:20.28 Lysis1.configure :default @22:11:20.38 Lysis2.configure :default @22:11:20.51 Plunge.configure :default @22:11:20.64 SamplePump.configure :default @22:11:20.77 Toroid.configure :default @22:11:20.89 Carousel.configure :default @22:11:21.03 Pressure.configure :default @22:11:21.18 ExtraPump.configure :default @22:11:21.29 All elf controllers running firmware version 4.79 @22:11:21.33 Gate.power :motor,:ON,limit to 5000mA @22:11:21.77 Archive.home.jog 0 @22:11:22.27 Carousel.home.jog 0 @22:11:22.30 Plunge.home.jog 0 @22:11:22.38 Lysis2.home.jog 0 @22:11:22.42 Air.home.jog 0 @22:11:22.47 Toroid.home.jog 0 @22:11:22.55 Lysis1.home.jog 0 @22:11:23.27 Archive.in :homing @22:11:23.57 Archive.jog 1359 @22:11:23.63 Toroid.in :homing @22:11:23.68 Lysis2.in :homing @22:11:23.73 Air.in :homing @22:11:23.83 Lysis1.in :homing @22:11:23.88 Plunge.in :homing @22:11:24.19 Toroid.jog 204 @22:11:24.71 Lysis2.jog 1360 @22:11:24.85 Plunge.jog 810 @22:11:24.90 Air.jog 1361 @22:11:24.96 Lysis1.jog 1351 @22:11:25.35 Archive.setRawPosition! 50 @22:11:25.44 Archive.seek :home @22:11:25.76 Archive.in :default @22:11:25.87 Toroid.setRawPosition! 0 @22:11:25.95 Toroid.seek :home @22:11:26.09 Plunge.setRawPosition! 50 @22:11:26.17 Plunge.seek :home @22:11:26.31 Toroid.in :default @22:11:26.33 Lysis2.setRawPosition! 50 @22:11:26.51 Lysis2.seek :home @22:11:26.65 Lysis1.setRawPosition! 50 @22:11:26.69 Air.setRawPosition! 50 @22:11:26.73 Plunge.in :default @22:11:26.94 Lysis1.seek :home @22:11:26.98 Air.seek :home @22:11:27.20 Lysis2.in :default @22:11:27.33 Lysis1.in :default @22:11:27.47 Air.in :default @22:11:27.82 Toroid.seek :clear @22:11:29.47 Carousel.in :default @22:11:29.63 Carousel.home.seek 33 @22:11:30.09 Selecting Cartridge 33 @22:11:30.36 Carousel.seek 33 @22:11:31.13 Lysis1.in :fast @22:11:31.28 Lysis1.seek :locked @22:11:33.57 Plunge.seek :locked @22:11:33.76 Air.in :fast @22:11:33.85 Air.seek :locked @22:11:35.42 Carousel.reconfigure :locked @22:11:35.52 Carousel.jog 0 @22:11:36.22 Mounted archive Cartridge @22:11:36.61 Preparing to filter cartridge 33 @22:11:36.95 Priming sample loop w/30ml, bypass w/10ml @22:11:36.97 SamplePump.setPosition! 0ml @22:11:37.07 Bypass.open @22:11:38.47 Intake.open @22:11:39.71 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @22:11:42.30 Vacuum tare is 19% of full scale @22:11:42.49 Sea pressure (Abs) tare is 10% of full scale @22:11:42.68 Pressure.in :default @22:11:42.78 Pressure.hold @22:11:43.03 SamplePump.in :prime @22:11:43.13 SamplePump.seek 10ml,59 seconds @22:11:52.76 Pressure.stop @22:11:52.84 SamplePump.setPosition! 0ml @22:11:52.93 Exhaust.open @22:11:54.28 Bypass.close @22:11:55.85 Pressure.in :default @22:11:55.95 Pressure.hold @22:11:56.33 SamplePump.in :prime @22:11:56.43 SamplePump.seek 30ml,1:56 @22:12:25.36 Pressure.stop @22:12:25.47 Bypass.open @22:12:26.08 Intake.close @22:12:26.81 Toroid.in :hold @22:12:26.91 Toroid.seek :crack @22:12:28.48 Toroid.seek :cartridge @22:12:29.45 Toroid.in :default @22:12:29.55 Toroid.seek :clear @22:12:31.56 Pressurizing cartridge to 26psi above 14.6psia @22:12:31.58 SamplePump.setPosition! 0ml @22:12:31.67 Intake.open @22:12:32.30 Bypass.close @22:12:32.92 Exhaust.close @22:12:33.77 Pressure.in :default @22:12:33.87 Pressure.hold @22:12:34.13 SamplePump.in :charge @22:12:34.23 SamplePump.seek 2.3ml,42 seconds @22:12:42.53 Pressure.stop @22:12:42.63 Intake.close @22:12:43.94 Pressurized cartridge with 0.328ml to 27.1psi @22:12:43.95 Isolated @38.3psia (23.7psi) @22:12:43.99 Verifying cartridge holds at least 0.65..0.85 of 38.3psia @22:12:44.03 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @22:12:48.74 Cartridge pressure fell 1% to 38.1psia @22:12:48.88 Sampling 134.0ml in 13:10 @22:12:48.90 SamplePump.setPosition! 0ml @22:12:49.01 Exhaust.open @22:12:49.68 Intake.open @22:12:50.57 Pressure.in :default @22:12:50.66 Pressure.hold @22:12:51.06 SamplePump.in :sample @22:12:51.20 SamplePump.seek 134ml,11:40 @22:12:53.56 Cartridge 33 filtering 1/134ml at 0.74ml/s with 21.2psi vacuum 13.4m deep (34.5psia) @22:13:53.58 Cartridge 33 filtering 41/134ml at 0.66ml/s with 19.4psi vacuum @22:14:53.58 Cartridge 33 filtering 81/134ml at 0.60ml/s with 38.5psi vacuum @22:15:53.57 Cartridge 33 filtering 121/134ml at 0.74ml/s with 19.5psi vacuum 17.5m deep (40.5psia) @22:16:01.53 SamplePump.stop @22:16:01.63 Intake.close @22:16:01.72 Exhaust.close @22:16:01.99 Toroid.in :hold @22:16:02.10 Toroid.seek :bypass @22:16:03.77 Toroid.in :default @22:16:03.87 Toroid.seek :clear @22:16:05.52 Pressure.stop @22:16:06.03 Cartridge::Sampler::Leaky in FILTERING -- Serious Leak or Stall -- 0.71ml/s made only 17.3psi vacuum after 126.0ml @22:16:06.05 Waiting to Resume from Checkpoint "Sample Pump (SP) pressureOutOfBounds at 125.97ml" @22:18:28.42 Cmd::Error in brent -- Not Filtering @22:18:28.50 UserAbort in brent -- User Abort!! @22:18:43.07 -> trouble >>> Thread[:FILTERING] is suspended <<< @22:11:36 Preparing to filter cartridge 33 @22:11:36 Priming sample loop w/30ml, bypass w/10ml @22:11:39 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @22:12:31 Pressurizing cartridge to 26psi above 14.6psia @22:12:37 Sample Pump (SP) pressureOutOfBounds at 0.33ml @22:12:43 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @22:12:48 Sampling 134.0ml in 13:10 @22:15:53 Sample Pump (SP) pressureOutOfBounds at 125.97ml @22:19:16.65 -> Cmd.resume -2 @22:19:16.68 Resuming Thread (suspended since 22:12:48) @22:19:16.72 Sampling 134.0ml in 13:10 @22:19:17.36 SamplePump.setPosition! 0ml @22:19:17.46 Exhaust.open @22:19:18.09 Intake.open @22:19:18.95 Pressure.in :default @22:19:19.05 Pressure.hold @22:19:19.49 SamplePump.seek 134ml,11:40 @22:19:21.95 Cartridge 33 filtering 1/134ml at 0.70ml/s with 46.6psi vacuum @22:19:57.69 SamplePump.stop @22:19:57.78 Intake.close @22:19:57.86 Exhaust.close @22:19:58.68 Pressure.stop @22:19:59.24 Cartridge::Sampler::Leaky in FILTERING -- Serious Leak or Stall -- 0.72ml/s made only 17.0psi vacuum after 24.7ml @22:19:59.26 Waiting to Resume from Checkpoint "Sample Pump (SP) pressureOutOfBounds at 24.66ml" @22:20:06.60 Cmd::Error in brent -- Not Processing @22:20:06.67 UserAbort in brent -- User Abort!! @22:20:16.09 -> BACsampler.vacuum 18..26 @22:20:27.91 -> BACsampler.vacuum=12..26 12..26 @22:20:31.51 -> Cmd.resume -2 @22:20:31.55 Resuming Thread after Sample Pump (SP) pressureOutOfBounds at 125.97ml at 22:15:53 @22:20:31.60 SamplePump.in :sample @22:20:31.75 SamplePump.seek 134ml,11:40 @22:20:33.57 Flow averaged 0.05ml/s over 7:43 @22:20:33.72 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @22:20:33.75 Pressure.stop @22:20:34.00 Sampled 49.6ml :PAUSED @22:20:38.63 -> trouble @22:21:10.42 -> slots {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 32..30 => { Type: :archiveNull_bac, State: :dry}, 33 => { Type: :archiveNull_bac, State: :leaky, filtered: 200.3}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:21:52.81 -> slot 33=>:dry {33 => { Type: :archiveNull_bac, State: :dry, filtered: 200.3}} @22:22:13.92 -> Cmd.fire nil, :archiveNull_bac @22:22:13.97 Selecting Cartridge 33 @22:22:14.68 Preparing to filter cartridge 33 @22:22:14.70 Cartridge already filtered 200.3ml @22:22:15.10 Cartridge::Error in brent -- Cannot process dry cartridge 33 @22:22:27.81 -> Cmd.status {loadedCartridge: 33, state: :PAUSED, type: :archiveNull_bac, volumeFiltered: 200.3} @22:24:08.31 -> Cmd.reloadCartridge! :READY @22:24:08.34 Cartridge::InvalidState in brent -- :READY is not dry, standard, wet, filtering, paused, processed, postprocessing, postprocessed, missing, reserved, incompatible, leaky, leakyToroid, failedLoading, failedFiltering, processing, failedProcessing or preserving @22:24:13.72 -> Cmd.reloadCartridge! :dry @22:24:13.87 Selecting Cartridge 33 33 @22:24:18.62 -> Cmd.status {loadedCartridge: 33, state: :READY, type: :archiveNull_bac} @22:24:32.88 -> Cmd.fire nil, :archiveNull_bac @22:24:32.93 Selecting Cartridge 33 @22:24:33.72 Preparing to filter cartridge 33 @22:24:33.74 Cartridge already filtered 200.3ml @22:24:34.13 Cartridge::Error in brent -- Cannot process dry cartridge 33 @22:25:18.43 -> Cart { Type: :archiveNull_bac, State: :dry, filtered: 200.3} @22:25:29.29 -> Cart[:filtered] @22:25:51.21 -> Cart.update filered:nil {33 => {filered: nil}} @22:25:54.20 -> Cart { Type: :archiveNull_bac, State: :dry, filtered: 200.3} @22:26:06.48 -> Cmd.reloadCartridge! :dry @22:26:06.64 Selecting Cartridge 33 33 @22:26:10.20 -> Cart { Type: :archiveNull_bac, State: :dry, filtered: 200.3} @22:26:53.06 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 32..30 => { Type: :archiveNull_bac, State: :dry}, 33 => { Type: :archiveNull_bac, State: :dry, filtered: 200.3}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:27:43.60 -> Cart.update filtered:nil {33 => {filtered: nil}} @22:27:46.08 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 33..30 => { Type: :archiveNull_bac, State: :dry}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:28:06.94 -> Cmd.reloadCartridge! @22:28:06.97 ArgumentError in brent -- wrong number of arguments (0 for 1) @22:28:11.60 -> Cmd.reloadCartridge! :dry @22:28:11.76 Selecting Cartridge 33 33 @22:28:15.13 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, 33..30 => { Type: :archiveNull_bac, State: :dry}, 34 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:28:26.71 -> Cmd.status {loadedCartridge: 33, state: :READY, type: :archiveNull_bac} @22:28:43.18 -> Cmd.fire nil, :archiveNull_bac @22:28:43.25 Selecting Cartridge 33 @22:28:43.95 Preparing to filter cartridge 33 @22:28:44.29 Priming sample loop w/30ml, bypass w/10ml @22:28:44.31 SamplePump.setPosition! 0ml @22:28:44.41 Bypass.open @22:28:45.79 Intake.open @22:28:46.51 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @22:28:49.10 Vacuum tare is 19% of full scale @22:28:49.33 Sea pressure (Abs) tare is 10% of full scale @22:28:50.00 Pressure.in :default @22:28:50.14 Pressure.hold @22:28:50.39 SamplePump.in :prime @22:28:50.50 SamplePump.seek 10ml,59 seconds @22:29:00.07 Pressure.stop @22:29:00.17 SamplePump.setPosition! 0ml @22:29:00.24 Exhaust.open @22:29:01.62 Bypass.close @22:29:03.16 Pressure.in :default @22:29:03.29 Pressure.hold @22:29:03.68 SamplePump.in :prime @22:29:03.79 SamplePump.seek 30ml,1:56 @22:29:33.05 Pressure.stop @22:29:33.28 Bypass.open @22:29:33.89 Intake.close @22:29:34.62 Toroid.in :hold @22:29:34.71 Toroid.seek :crack @22:29:36.29 Toroid.seek :cartridge @22:29:37.26 Toroid.in :default @22:29:37.36 Toroid.seek :clear @22:29:39.42 Pressurizing cartridge to 26psi above 14.5psia @22:29:39.44 SamplePump.setPosition! 0ml @22:29:39.53 Intake.open @22:29:40.16 Bypass.close @22:29:40.80 Exhaust.close @22:29:41.65 Pressure.in :default @22:29:41.75 Pressure.hold @22:29:42.00 SamplePump.in :charge @22:29:42.10 SamplePump.seek 2.3ml,42 seconds @22:29:47.24 Pressure.stop @22:29:47.33 Intake.close @22:29:48.13 Pressurized cartridge with 0.122ml to 26.5psi @22:29:48.14 Isolated @40.6psia (26.1psi) @22:29:48.18 Verifying cartridge holds at least 0.65..0.85 of 40.6psia @22:29:48.24 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @22:29:52.93 Cartridge pressure fell 3% to 39.3psia @22:29:53.07 Sampling 134.0ml in 13:10 @22:29:53.09 SamplePump.setPosition! 0ml @22:29:53.23 Exhaust.open @22:29:53.90 Intake.open @22:29:54.79 Pressure.in :default @22:29:54.89 Pressure.hold @22:29:55.33 SamplePump.in :sample @22:29:55.43 SamplePump.seek 134ml,11:40 @22:29:57.78 Cartridge 33 filtering 1/134ml at 0.69ml/s with 8.4psi vacuum 5.1m deep (22.2psia) @22:30:57.79 Cartridge 33 filtering 40/134ml at 0.69ml/s with 39.8psi vacuum @22:31:43.05 Session Begun @22:31:47.58 -> Sample.PSI @22:31:47.62 NameError in brent#2 -- uninitialized constant Sample @22:31:51.22 -> Sampler.PSI 12.425512439 @22:31:54.90 -> Sampler.PSI 6.476983013 @22:31:56.87 -> Sampler.PSI 20.784825808 @22:31:57.78 Cartridge 33 filtering 78/134ml at 0.71ml/s with 16.8psi vacuum 15.8m deep (38.0psia) @22:32:01.80 -> Sampler.PSI 44.138819343 @22:32:03.22 -> Sampler.PSI 6.338397202 @22:32:04.43 -> Sampler.PSI 46.886168827 @22:32:05.63 -> Sampler.PSI 13.147376993 @22:32:06.90 -> Sampler.PSI 11.321394714 @22:32:08.13 -> Sampler.PSI 42.219938883 @22:32:09.33 -> Sampler.PSI 13.864672784 @22:32:10.78 -> Sampler.PSI 16.497803193 @22:32:11.88 -> Sampler.PSI 13.237229332 @22:32:13.05 -> Sampler.PSI 21.004126432 @22:32:14.22 -> Sampler.PSI 8.968481769 @22:32:15.38 -> Sampler.PSI 47.414622414 @22:32:16.64 -> Sampler.PSI 16.357694461 @22:32:57.79 -> spLog=SP.log{delay 5};nil @22:32:57.83 Cartridge 33 filtering 115/134ml at 0.67ml/s with 6.3psi vacuum 7.1m deep (25.1psia) @22:32:58.07 delay 5 seconds @22:33:10.88 -> spLog.length 165 @22:33:27.31 Pressure.stop @22:33:27.51 Intake.close @22:33:27.56 Exhaust.close @22:33:27.90 Toroid.in :hold @22:33:28.01 Toroid.seek :bypass @22:33:29.69 Toroid.in :default @22:33:29.81 Toroid.seek :clear @22:33:31.45 Sampled 134.0ml @22:33:32.17 Plunge.seek :reagent @22:33:33.12 Sample loop closed. Ready to Deliver Reagents @22:33:33.33 Selecting Cartridge 32 @22:33:33.55 Carousel.in :default @22:33:33.73 Carousel.home.seek 33 @22:33:34.21 Air.in :unlocking @22:33:34.42 Air.seek :clear @22:33:35.88 Lysis1.in :unlocking @22:33:36.07 Lysis1.seek :clear @22:33:36.14 Plunge.in :unlocking @22:33:36.34 Plunge.seek :clear @22:33:37.59 Carousel.seek 32 @22:33:38.71 Lysis1.in :fast @22:33:38.94 Lysis1.seek :locked @22:33:41.11 -> hidelog Log display suppressed @22:33:41.41 Plunge.in :default @22:33:41.54 Plunge.seek :locked @22:33:42.24 Air.in :fast @22:33:42.34 Air.seek :locked @22:33:43.92 Carousel.reconfigure :locked @22:33:44.03 Carousel.jog 0 @22:33:44.73 Mounted archive Cartridge @22:33:45.10 Preparing to filter cartridge 32 @22:33:45.49 Priming sample loop w/30ml, bypass w/10ml @22:33:45.52 SamplePump.setPosition! 0ml @22:33:45.61 Bypass.open @22:33:47.01 Intake.open @22:33:47.75 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @22:33:50.34 Vacuum tare is 19% of full scale @22:33:50.53 Sea pressure (Abs) tare is 10% of full scale @22:33:50.72 Pressure.in :default @22:33:50.82 Pressure.hold @22:33:51.09 SamplePump.in :prime @22:33:51.23 SamplePump.seek 10ml,59 seconds @22:34:00.82 Pressure.stop @22:34:00.91 SamplePump.setPosition! 0ml @22:34:00.99 Exhaust.open @22:34:02.33 Bypass.close @22:34:03.89 Pressure.in :default @22:34:03.99 Pressure.hold @22:34:04.39 SamplePump.in :prime @22:34:04.49 SamplePump.seek 30ml,1:56 @22:34:34.09 Pressure.stop @22:34:34.19 Bypass.open @22:34:34.84 Intake.close @22:34:35.59 Toroid.in :hold @22:34:35.69 Toroid.seek :crack @22:34:37.29 Toroid.seek :cartridge @22:34:38.28 Toroid.in :default @22:34:38.38 Toroid.seek :clear @22:34:41.01 Pressurizing cartridge to 26psi above 14.6psia @22:34:41.03 SamplePump.setPosition! 0ml @22:34:41.14 Intake.open @22:34:41.82 Bypass.close @22:34:42.47 Exhaust.close @22:34:43.37 Pressure.in :default @22:34:43.47 Pressure.hold @22:34:43.73 SamplePump.in :charge @22:34:43.83 SamplePump.seek 2.3ml,42 seconds @22:34:50.48 Pressure.stop @22:34:50.58 Intake.close @22:34:51.40 Pressurized cartridge with 0.208ml to 26.5psi @22:34:51.41 Isolated @41.2psia (26.5psi) @22:34:51.46 Verifying cartridge holds at least 0.65..0.85 of 41.2psia @22:34:51.52 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @22:34:56.21 Cartridge pressure fell 1% to 40.9psia @22:34:56.34 Sampling 134.0ml in 13:10 @22:34:56.36 SamplePump.setPosition! 0ml @22:34:56.48 Exhaust.open @22:34:57.09 Intake.open @22:34:58.03 Pressure.in :default @22:34:58.13 Pressure.hold @22:34:58.53 SamplePump.in :sample @22:34:58.64 SamplePump.seek 134ml,11:40 @22:35:01.02 Cartridge 32 filtering 1/134ml at 0.65ml/s with 22.0psi vacuum @22:35:14.85 -> spLog.map{|s| Sampler::DeltaSkew(s.deltaPress)}.minmax @22:35:14.88 NoMethodError in brent#2 -- undefined method `DeltaSkew' for Cartridge::Sampler:Class @22:35:57.74 -> spLog.map{|s| Sampler::DeltaSkew.apply s.deltaPress}.minmax [6.17138353233333,49.2334977283333] @22:36:01.03 Cartridge 32 filtering 41/134ml at 0.74ml/s with 23.8psi vacuum 14.5m deep (36.2psia) @22:36:16.64 -> sp2Log=SP.log{delay 5};nil @22:36:16.79 delay 5 seconds @22:36:35.20 -> sp2Log.map{|s| Sampler::DeltaSkew.apply s.deltaPress}.minmax [7.63338769233333,47.1379584323333] @22:37:01.03 Cartridge 32 filtering 80/134ml at 0.71ml/s with 18.6psi vacuum 2.0m deep (17.7psia) @22:37:11.59 -> sp3Log=SP.log{delay 5};nil @22:37:11.71 delay 5 seconds @22:37:23.04 -> sp3Log.map{|s| Sampler::DeltaSkew.apply s.deltaPress}.minmax [7.67298363833333,46.8607868103333] @22:38:01.03 Cartridge 32 filtering 119/134ml at 0.72ml/s with 18.6psi vacuum 15.8m deep (38.1psia) @22:38:23.70 Pressure.stop @22:38:23.88 Intake.close @22:38:23.93 Exhaust.close @22:38:24.19 Toroid.in :hold @22:38:24.29 Toroid.seek :bypass @22:38:25.96 Toroid.in :default @22:38:26.05 Toroid.seek :clear @22:38:27.69 Sampled 134.0ml @22:38:28.94 Plunge.seek :reagent @22:38:29.87 Sample loop closed. Ready to Deliver Reagents @22:38:30.10 Carousel.in :default @22:38:30.27 Carousel.home.seek 32 @22:38:30.63 Plunge.seek :locked @22:38:31.74 Air.in :unlocking @22:38:31.90 Air.seek :clear @22:38:32.03 Lysis1.in :unlocking @22:38:32.25 Lysis1.seek :clear @22:38:34.05 Gate.power :motor,:OFF @22:38:34.08 Gate.power :core,:OFF @22:38:34.11 Gate.power :analytic1,:OFF @22:38:34.17 Gate.power :analytic2,:OFF @22:38:34.20 Gate.power :analytic3,:OFF @22:38:34.23 Gate.power :main,:OFF @22:38:34.30 Safely stopped and ready to power off :STOPPED @22:39:24.88 -> slot {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, [31,30] => { Type: :archiveNull_bac, State: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @22:39:39.93 -> can Can@22:39:40, 20.0C, 33% humidity, 14.5psia, 14.870V, 0.068A, 1.01W @22:40:07.90 -> Gate.version 1.12 @22:41:37.08 -> SP.elf.signon ESP3 Core 20kHz Elf boot v4.79 @00:30:46.01PDT04-Apr-23 Session Ended @11:50:04.32

Session Begun @11:50:08.74 -> BACsampler.prime @11:50:08.82 BusOff in p -- core bus was not powered while reading Storage Carousel (SC)'s status @11:50:14.51 -> ESP.ready! @11:50:14.56 Gate.power :main,:ON,limit to 5000mA @11:50:14.60 Gate.power :analytic1,:ON,limit to 5000mA @11:50:14.66 Gate.power :analytic2,:ON,limit to 5000mA @11:50:14.70 Gate.power :analytic3,:ON,limit to 5000mA @11:50:14.81 Powering core bus @11:50:18.65 Archive.configure :default @11:50:18.78 Air.configure :default @11:50:18.89 Lysis1.configure :default @11:50:19.01 Lysis2.configure :default @11:50:19.15 Plunge.configure :default @11:50:19.33 SamplePump.configure :default @11:50:19.46 Toroid.configure :default @11:50:19.61 Carousel.configure :default @11:50:19.74 Pressure.configure :default @11:50:19.88 ExtraPump.configure :default @11:50:19.99 All elf controllers running firmware version 4.794 @11:50:20.02 Gate.power :motor,:ON,limit to 5000mA @11:50:20.27 Archive.home.jog 0 @11:50:20.94 Carousel.home.jog 0 @11:50:20.99 Toroid.home.jog 0 @11:50:21.06 Plunge.home.jog 0 @11:50:21.11 Lysis1.home.jog 0 @11:50:21.15 Air.home.jog 0 @11:50:21.27 Lysis2.home.jog 0 @11:50:21.85 Archive.in :homing @11:50:22.26 Toroid.in :homing @11:50:22.35 Archive.jog 1362 @11:50:22.42 Plunge.in :homing @11:50:22.48 Lysis1.in :homing @11:50:22.73 Toroid.jog 591 @11:50:22.78 Plunge.jog 818 @11:50:22.88 Lysis1.jog 1349 @11:50:23.20 Air.in :homing @11:50:23.25 Lysis2.in :homing @11:50:23.43 Air.jog 1363 @11:50:23.49 Lysis2.jog 1359 @11:50:23.77 Archive.setRawPosition! 50 @11:50:23.87 Archive.seek :home @11:50:24.00 Plunge.setRawPosition! 50 @11:50:24.10 Plunge.seek :home @11:50:24.23 Lysis1.setRawPosition! 50 @11:50:24.33 Lysis1.seek :home @11:50:24.48 Plunge.in :default @11:50:24.53 Archive.in :default @11:50:24.79 Lysis1.in :default @11:50:25.43 Air.setRawPosition! 50 @11:50:25.48 Lysis2.setRawPosition! 50 @11:50:25.68 Lysis2.seek :home @11:50:25.73 Air.seek :home @11:50:25.95 Toroid.setRawPosition! 0 @11:50:26.04 Toroid.seek :home @11:50:26.25 Lysis2.in :default @11:50:26.28 Air.in :default @11:50:26.33 Toroid.in :default @11:50:26.82

Toroid.seek :clear @11:50:28.47 Carousel.in :default @11:50:28.65 Carousel.home.seek 33 Archive = Archive Syringe (ArS) clear Air = Air Syringe (AirS) clear Lysis1 = Lysis Syringe #1 (LyS1) clear Lysis2 = Lysis Syringe #2 (LyS2) clear Plunge = Plunge Valve (PV) clear Handoff Valve::Manifold selects blocked SamplePump = Sample Pump (SP) Not yet Homed! Intake is closed Exhaust is closed Bypass = Bypass (PB) is closed Toroid = Toroid Valve (TV) clear Carousel = Storage Carousel (SC) at 33 Pressure = Absolute Pressure (Leak) Sensor @15.7psia Toxicant = External Toxicant Valve::Manifold selects exhaust @11:50:36.04 -> BACsampler.prime @11:50:36.18 Priming sample loop w/30ml, bypass w/10ml @11:50:36.21 SamplePump.setPosition! 0ml @11:50:36.32 Bypass.open @11:50:37.72 Intake.open @11:50:38.44 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @11:50:41.03 Vacuum tare is 18% of full scale @11:50:41.27 Sea pressure (Abs) tare is 10% of full scale @11:50:41.47 Pressure.in :default @11:50:41.57 Pressure.hold @11:50:41.83 SamplePump.in :prime @11:50:41.96 SamplePump.seek 10ml,59 seconds @11:50:51.55 Pressure.stop @11:50:51.64 SamplePump.setPosition! 0ml @11:50:51.73 Exhaust.open @11:50:53.07 Bypass.close @11:50:54.67

Pressure.in :default @11:50:54.77 Pressure.hold @11:50:55.19 SamplePump.in :prime @11:50:55.32 SamplePump.seek 30ml,1:56 @11:51:24.82 Pressure.stop BACsampler @11:51:59.66 -> slots {10..1 => { Type: :aRNAl_bac, State: :reserved, was: :dry}, [31,30] => { Type: :archiveNull_bac, State: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @11:52:20.10 -> Cartridge.reserve 30,31 2 @11:52:40.91 -> Cartridge.release 1..10 10 @11:52:42.62 -> slots {10..1 => { Type: :aRNAl_bac, State: :dry}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134.0}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150.0}} @11:52:46.39 -> exit @11:52:46.41 Session Ended Log::Locked in trapHandler -- Another process is already writing to /var/log/esp/real.log @15:14:34.18 Slide::Error in core -- Storage Carousel (SC) positionErr at 33 (sensed 33 + 56 counts) @16:55:06.09PDT04-Apr-23

>BREAK< ESP3 Gateway v1.12 for core bus @16:55:06.12 >BREAK< ESP3 Gateway v1.12 for cartridge bus @16:55:09.59 Configuration for mv3 11/14/22 by preston@mbari.org /home/esp/esp2/type/auv/mv3/configure.rb @16:55:10.08 Sea pressure (Abs) tare is 9% of full scale @16:55:12.61 Polling Can every 2:00 @16:55:12.67 Waiting for espclients... @16:55:24.02 Session Begun @16:55:27.85 -> ESP.ready! @16:55:27.93 Gate.power :main,:ON,limit to 5000mA @16:55:27.95 Gate.power :analytic1,:ON,limit to 5000mA @16:55:28.00 Gate.power :analytic2,:ON,limit to 5000mA @16:55:28.04 Gate.power :analytic3,:ON,limit to 5000mA @16:55:28.13 Powering core bus @16:55:31.35 Archive.configure :default @16:55:31.47 Air.configure :default @16:55:31.57 Lysis1.configure :default @16:55:31.66 Lysis2.configure :default @16:55:31.78 Plunge.configure :default @16:55:31.90 SamplePump.configure :default @16:55:32.02 Toroid.configure :default @16:55:32.14 Carousel.configure :default @16:55:32.26 Pressure.configure :default @16:55:32.43 ExtraPump.configure :default @16:55:32.53 All elf controllers running firmware version 4.794 @16:55:32.59 Gate.power :motor,:ON,limit to 5000mA @16:55:32.99 Archive.home.jog 0 @16:55:33.47 Carousel.home.jog 0 @16:55:33.53 Plunge.home.jog 0 @16:55:33.56 Lysis2.home.jog 0 @16:55:33.61 Air.home.jog 0 @16:55:33.65 Toroid.home.jog 0 @16:55:33.72 Lysis1.home.jog 0 @16:55:34.42 Archive.in :homing @16:55:34.67 Archive.jog 1361 @16:55:34.73 Plunge.in :homing @16:55:34.78 Lysis1.in :homing @16:55:34.83 Toroid.in :homing @16:55:34.89 Lysis2.in :homing @16:55:34.98 Air.in :homing @16:55:35.29 Plunge.jog 289 @16:55:35.32 Lysis1.jog 1343 @16:55:35.37 Toroid.jog 592 @16:55:35.43 Lysis2.jog 1358 @16:55:35.47 Air.jog 1358 @16:55:36.15 Plunge.setRawPosition! 50 @16:55:36.23 Plunge.seek :home @16:55:36.37 Archive.setRawPosition! 50 @16:55:36.45 Archive.seek :home @16:55:36.57 Plunge.in :default @16:55:36.70 Lysis1.setRawPosition! 50 @16:55:36.81 Archive.in :default @16:55:36.85 Lysis1.seek :home @16:55:37.03 Lysis2.setRawPosition! 50 @16:55:37.09 Air.setRawPosition! 50 @16:55:37.15 Lysis2.seek :home @16:55:37.30 Air.seek :home @16:55:37.43 Lysis1.in :default @16:55:37.55 Lysis2.in :default @16:55:37.69 Air.in :default @16:55:37.72 Toroid.setRawPosition! 0 @16:55:37.87 Toroid.seek :home @16:55:38.00 Toroid.in :default @16:55:38.12 Toroid.seek :clear @16:55:39.76 Carousel.in :default @16:55:39.91 Carousel.home.seek 45 Archive = Archive Syringe (ArS) clear Air = Air Syringe (AirS) clear Lysis1 = Lysis Syringe #1 (LyS1) clear Lysis2 = Lysis Syringe #2 (LyS2) clear Plunge = Plunge Valve (PV) clear Handoff Valve::Manifold selects blocked SamplePump = Sample Pump (SP) Not yet Homed! Intake is closed Exhaust is closed Bypass = Bypass (PB) is closed Toroid = Toroid Valve (TV) clear Carousel = Storage Carousel (SC) at 45 Pressure = Absolute Pressure (Leak) Sensor @28.7psia Toxicant = External Toxicant Valve::Manifold selects exhaust @16:55:44.39 -> slots {10..1 => { Type: :aRNAl_bac, State: :dry}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @16:55:55.25 -> Cart.dry [1,2,3,4,5,6,7,8,9,10] @16:56:18.93 -> ESP.main.exit # @16:56:19.12 ThreadError in brent -- killed thread @16:56:19.17 Session Ended @10:17:17.79PDT05-Apr-23
>BREAK< ESP3 Gateway v1.12 for core bus @10:17:17.81 >BREAK< ESP3 Gateway v1.12 for cartridge bus @10:17:21.27 Configuration for mv3 11/14/22 by preston@mbari.org /home/esp/esp2/type/auv/mv3/configure.rb @10:17:21.83 Sea pressure (Abs) tare is 9% of full scale @10:17:24.47 Polling Can every 2:00 @10:17:24.54 Waiting for espclients... @10:17:33.13 Session Begun @10:17:36.37 -> can Can@10:17:36, 20.8C, 35% humidity, 14.5psia, 14.860V, 0.220A, 3.27W @10:17:50.34 -> ESP.ready! @10:17:50.86 Gate.power :analytic1,:ON,limit to 5000mA @10:17:50.93 Gate.power :analytic2,:ON,limit to 5000mA @10:17:50.97 Gate.power :analytic3,:ON,limit to 5000mA @10:17:51.42 Archive.configure :default @10:17:51.61 Air.configure :default @10:17:51.78 Lysis1.configure :default @10:17:51.94 Lysis2.configure :default @10:17:52.13 Plunge.configure :default @10:17:52.32 SamplePump.configure :default @10:17:52.52 Toroid.configure :default @10:17:52.61 Toroid.hold @10:17:52.72 Toroid.configure :default @10:17:52.91 Carousel.configure :default @10:17:53.00 Carousel.hold @10:17:53.11 Carousel.configure :default @10:17:53.30 Pressure.configure :default @10:17:53.55 ExtraPump.configure :default @10:17:53.66 All elf controllers running firmware version 4.794 @10:17:54.39 Toroid.seek :clear @10:17:54.50 Carousel.in :default @10:17:54.66 Carousel.home.seek 45 Archive = Archive Syringe (ArS) clear Air = Air Syringe (AirS) clear Lysis1 = Lysis Syringe #1 (LyS1) clear Lysis2 = Lysis Syringe #2 (LyS2) clear Plunge = Plunge Valve (PV) clear Handoff Valve::Manifold selects blocked SamplePump = Sample Pump (SP) Not yet Homed! Intake is in an unknown state Exhaust is in an unknown state Bypass = Bypass (PB) is in an unknown state Toroid = Toroid Valve (TV) clear Carousel = Storage Carousel (SC) at 45 Pressure = Absolute Pressure (Leak) Sensor @28.5psia Toxicant = External Toxicant Valve::Manifold selects exhaust @10:18:02.82 -> Cmd.stop @10:18:02.96 Intake.close @10:18:03.01 Exhaust.close @10:18:03.10 Bypass.close @10:18:03.94 Carousel.in :default @10:18:04.10 Carousel.home.seek 45 @10:18:04.50 Lysis1.in :fast @10:18:04.60 Lysis1.seek :locked @10:18:06.79 Plunge.seek :locked @10:18:07.85 Lysis1.in :unlocking @10:18:08.05 Lysis1.seek :clear @10:18:10.35 Gate.power :motor,:OFF @10:18:10.38 Gate.power :core,:OFF @10:18:10.42 Gate.power :analytic1,:OFF @10:18:10.46 Gate.power :analytic2,:OFF @10:18:10.49 Gate.power :analytic3,:OFF @10:18:10.54 Gate.power :main,:OFF @10:18:10.57 Safely stopped and ready to power off :STOPPED @10:18:21.53 -> can Can@10:18:21, 20.8C, 35% humidity, 14.5psia, 14.866V, 0.091A, 1.36W @10:18:30.32 -> can Can@10:18:30, 20.8C, 35% humidity, 14.5psia, 14.866V, 0.091A, 1.35W @10:22:48.86 -> Thread.current.keys [:client,:slideNest] @10:23:39.61 -> ESP.client @10:23:39.64 NoMethodError in brent -- undefined method `client' for ESP:Module @10:23:42.36 -> ESP.clients [ESP["brent"]] @10:23:44.58 -> client ESP["brent"] @10:23:54.08 -> Thread.current[:client] ESP["brent"] @10:43:05.10 -> self ESP["brent"] @10:43:29.56 -> instance_variables [:@outputLine, :@maxCompletions, :@keyboardName, :@binding, :@_, :@oldPrompt, :@reader, :@showStatus, :@keyboard, :@thread, :@logQ, :@log] @10:54:37.72 -> list Cmd.method :runCartridge def runCartridge *args, &criteria #load cartridge, filter, process specified cartridge and stop client=Thread.current[:client] slotNum = loadCartridge *args, &criteria if quiet = client && !client.showingLog? state = "#{Cartridge.state} " rest = "#{Cartridge.type} cartridge #{slotNum}" end if @state != :PROCESS #no filtering :standard cartridges client.puts "Filtering #{state}#{rest}" if quiet filter state = nil end client.puts "Processing #{state}#{rest}" if quiet process end def runStandard #run the next standard cartridge with logging hidden client=Thread.current[:client] and client.hideLog @10:55:06.95 -> slot {10..1 => { Type: :aRNAl_bac, State: :dry}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @11:05:48.23 -> ESP.ready! @11:05:48.30 Gate.power :main,:ON,limit to 5000mA @11:05:48.33 Gate.power :analytic1,:ON,limit to 5000mA @11:05:48.36 Gate.power :analytic2,:ON,limit to 5000mA @11:05:48.40 Gate.power :analytic3,:ON,limit to 5000mA @11:05:48.52 Powering core bus @11:05:52.38 Archive.configure :default @11:05:52.52 Air.configure :default @11:05:52.61 Lysis1.configure :default @11:05:52.71 Lysis2.configure :default @11:05:52.83 Plunge.configure :default @11:05:52.96 SamplePump.configure :default @11:05:53.08 Toroid.configure :default @11:05:53.21 Carousel.configure :default @11:05:53.37 Pressure.configure :default @11:05:53.51 ExtraPump.configure :default @11:05:53.61 All elf controllers running firmware version 4.794 @11:05:53.65 Gate.power :motor,:ON,limit to 5000mA @11:05:53.99 Archive.home.jog 0 @11:05:54.52 Air.home.jog 0 @11:05:54.61 Toroid.home.jog 0 @11:05:54.68 Lysis2.home.jog 0 @11:05:54.73 Lysis1.home.jog 0 @11:05:54.80 Plunge.home.jog 0 @11:05:54.84 Carousel.home.jog 0 @11:05:55.60 Archive.in :homing @11:05:55.91 Air.in :homing @11:05:55.99 Plunge.in :homing @11:05:56.05 Lysis1.in :homing @11:05:56.11 Archive.jog 1358 @11:05:56.18 Toroid.in :homing @11:05:56.23 Lysis2.in :homing @11:05:56.60 Air.jog 1358 @11:05:56.63 Plunge.jog 811 @11:05:56.67 Lysis1.jog 1346 @11:05:56.72 Toroid.jog 583 @11:05:56.78 Lysis2.jog 1360 @11:05:57.61 Archive.setRawPosition! 50 @11:05:57.70 Archive.seek :home @11:05:57.84 Plunge.setRawPosition! 50 @11:05:57.92 Plunge.seek :home @11:05:58.07 Archive.in :default @11:05:58.10 Air.setRawPosition! 50 @11:05:58.28 Air.seek :home @11:05:58.44 Lysis2.setRawPosition! 50 @11:05:58.48 Lysis1.setRawPosition! 50 @11:05:58.52 Plunge.in :default @11:05:58.72 Lysis2.seek :home @11:05:58.76 Lysis1.seek :home @11:05:59.00 Toroid.setRawPosition! 0 @11:05:59.02 Air.in :default @11:05:59.63 Toroid.seek :home @11:05:59.90 Lysis2.in :default @11:05:59.93 Lysis1.in :default @11:05:59.97 Toroid.in :default @11:06:00.48 Toroid.seek :clear @11:06:02.11 Carousel.in :default @11:06:02.28 Carousel.home.seek 45 Archive = Archive Syringe (ArS) clear Air = Air Syringe (AirS) clear Lysis1 = Lysis Syringe #1 (LyS1) clear Lysis2 = Lysis Syringe #2 (LyS2) clear Plunge = Plunge Valve (PV) clear Handoff Valve::Manifold selects blocked SamplePump = Sample Pump (SP) Not yet Homed! Intake is closed Exhaust is closed Bypass = Bypass (PB) is closed Toroid = Toroid Valve (TV) clear Carousel = Storage Carousel (SC) at 45 Pressure = Absolute Pressure (Leak) Sensor @28.4psia Toxicant = External Toxicant Valve::Manifold selects exhaust @11:06:56.75 -> Cmd.runCartridge @11:06:57.50 Toroid.seek :clear @11:06:57.62 Carousel.in :default @11:06:57.79 Carousel.home.seek 45 @11:06:58.09 Selecting Cartridge 10 @11:06:58.36 Carousel.seek 10 @11:07:06.37 Lysis1.in :fast @11:07:06.47 Lysis1.seek :locked @11:07:08.77 Plunge.seek :locked @11:07:08.95 Air.in :fast @11:07:09.05 Air.seek :locked @11:07:10.60 Carousel.reconfigure :locked @11:07:10.71 Carousel.jog 0 @11:07:11.42 Mounted archive Cartridge @11:07:11.81 Preparing to filter cartridge 10 @11:07:12.16 Priming sample loop w/100ml, bypass w/10ml @11:07:12.18 SamplePump.setPosition! 0ml @11:07:12.27 Bypass.open @11:07:13.66 Intake.open @11:07:14.36 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @11:07:16.95 Vacuum tare is 21% of full scale @11:07:17.14 Sea pressure (Abs) tare is 10% of full scale @11:07:17.36 Pressure.in :default @11:07:17.48 Pressure.hold @11:07:17.75 SamplePump.in :prime @11:07:17.85 SamplePump.seek 10ml,59 seconds @11:07:27.42 Pressure.stop @11:07:27.50 SamplePump.setPosition! 0ml @11:07:27.58 Exhaust.open @11:07:28.91 Bypass.close @11:07:30.45 Pressure.in :default @11:07:30.55 Pressure.hold @11:07:30.95 SamplePump.in :prime @11:07:31.05 SamplePump.seek 100ml,5:16 @11:09:08.29 Pressure.stop @11:09:08.39 Bypass.open @11:09:09.01 Intake.close @11:09:09.75 Toroid.in :hold @11:09:09.85 Toroid.seek :crack @11:09:11.41 Toroid.seek :cartridge @11:09:12.38 Toroid.in :default @11:09:12.48 Toroid.seek :clear @11:09:14.50 Pressurizing cartridge to 26psi above 13.3psia @11:09:14.53 SamplePump.setPosition! 0ml @11:09:14.62 Intake.open @11:09:15.28 Bypass.close @11:09:15.94 Exhaust.close @11:09:16.79 Pressure.in :default @11:09:16.88 Pressure.hold @11:09:17.15 SamplePump.in :charge @11:09:17.25 SamplePump.seek 2.3ml,42 seconds @11:09:26.45 Pressure.stop @11:09:26.54 Intake.close @11:09:27.32 Pressurized cartridge with 0.404ml to 26.7psi @11:09:27.35 Isolated @28.4psia (15.1psi) @11:09:27.41 Verifying cartridge holds at least 0.65..0.85 of 28.4psia @11:09:27.46 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @11:09:32.15 Cartridge pressure fell 19% to 22.9psia @11:09:32.32 Toroid.in :hold @11:09:32.43 Toroid.seek :bypass @11:09:34.10 Toroid.in :default @11:09:34.20 Toroid.seek :clear @11:09:35.95 Cartridge::Sampler::Leaky in FILTERING -- Retained only 22.9psia @11:09:35.97 Waiting to Resume from Checkpoint "Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi" @11:10:17.79 Cmd::Error in brent -- Not Filtering @11:10:17.85 UserAbort in brent -- User Abort!! @11:10:53.88 -> BACsampler.prime 100,100 @11:10:54.01 Priming sample loop w/100ml, bypass w/100ml @11:10:54.04 SamplePump.setPosition! 0ml @11:10:54.12 Bypass.open @11:10:55.65 Intake.open @11:10:57.20 Pressure.in :default @11:10:57.29 Pressure.hold @11:10:57.60 SamplePump.in :prime @11:10:57.70 SamplePump.seek 100ml,5:16 @11:12:29.92 Pressure.stop @11:12:30.01 SamplePump.setPosition! 0ml @11:12:30.07 Exhaust.open @11:12:31.39 Bypass.close @11:12:32.94 Pressure.in :default @11:12:33.04 Pressure.hold @11:12:33.45 SamplePump.in :prime @11:12:33.55 SamplePump.seek 100ml,5:16 @11:14:09.67 Pressure.stop BACsampler @11:14:22.61 -> slot {9..1 => { Type: :aRNAl_bac, State: :dry}, 10 => { Type: :aRNAl_bac, State: :leaky}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @11:14:36.40 -> slot 10=>:dry {10 => { Type: :aRNAl_bac, State: :dry}} @11:14:51.44 -> Cmd.runCartridge @11:14:51.49 Selecting Cartridge 10 @11:14:52.21 Preparing to filter cartridge 10 @11:14:52.52 Bypass.open @11:14:53.16 Intake.close @11:14:53.88 Toroid.in :hold @11:14:53.97 Toroid.seek :crack @11:14:55.55 Toroid.seek :cartridge @11:14:56.54 Toroid.in :default @11:14:56.64 Toroid.seek :clear @11:14:58.77 Pressurizing cartridge to 26psi above 13.6psia @11:14:58.79 SamplePump.setPosition! 0ml @11:14:58.88 Intake.open @11:14:59.52 Bypass.close @11:15:00.17 Exhaust.close @11:15:01.04 Pressure.in :default @11:15:01.13 Pressure.hold @11:15:01.43 SamplePump.in :charge @11:15:01.54 SamplePump.seek 2.3ml,42 seconds @11:15:08.78 Pressure.stop @11:15:08.87 Intake.close @11:15:09.69 Pressurized cartridge with 0.248ml to 26.1psi @11:15:09.71 Isolated @40.0psia (26.3psi) @11:15:09.75 Verifying cartridge holds at least 0.65..0.85 of 40.0psia @11:15:09.82 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @11:15:14.61 Sampling 1000.0ml in 1:25:20 @11:15:14.64 SamplePump.setPosition! 0ml @11:15:14.74 Exhaust.open @11:15:15.40 Intake.open @11:15:16.30 Pressure.in :default @11:15:16.40 Pressure.hold @11:15:16.81 SamplePump.in :sample @11:15:16.91 SamplePump.seek 1000ml,1:23:50 @11:15:19.29 Cartridge 10 filtering 1/1000ml at 0.47ml/s with 21.9psi vacuum 4.3m deep (21.0psia) @11:16:19.29 Cartridge 10 filtering 34/1000ml at 0.53ml/s with 35.6psi vacuum @11:17:19.28 Cartridge 10 filtering 66/1000ml at 0.59ml/s with 15.7psi vacuum 11.2m deep (31.2psia) @11:18:14.29 Session Begun @11:18:19.29 Cartridge 10 filtering 95/1000ml at 0.44ml/s with 19.7psi vacuum @11:18:26.61 -> hidelog Log display suppressed @11:18:56.18 -> SPlog=SP.log{delay 5}; nil @11:18:56.32 delay 5 seconds @11:19:09.02 -> SPlog.length 166 @11:19:19.29 Cartridge 10 filtering 121/1000ml at 0.51ml/s with 29.8psi vacuum 10.4m deep (30.1psia) @11:19:42.88 -> SPlog.map{|l| Sampler::DeltaSkew l.deltaPress}.minmax @11:19:42.92 NoMethodError in bar -- undefined method `DeltaSkew' for Cartridge::Sampler:Class @11:20:10.20 -> Sampler::DeltaSkew 0.001522921(PSI/count)-21.1 @11:20:19.30 Cartridge 10 filtering 144/1000ml at 0.20ml/s with 26.5psi vacuum @11:20:19.54 -> SPlog.map{|l| Sampler::DeltaSkew.apply l.deltaPress}.minmax [11.9295478333333,45.7627607693333] @11:21:19.29 Cartridge 10 filtering 163/1000ml at 0.39ml/s with 30.9psi vacuum 9.7m deep (29.0psia) @11:21:57.36 -> Sea -3.2m deep @11:22:03.12 -> Abs Absolute Pressure (Leak) Sensor @32.6psia @11:22:19.28 Cartridge 10 filtering 180/1000ml at 0.36ml/s with 22.0psi vacuum 2.3m deep (18.1psia) @11:23:19.28 Cartridge 10 filtering 196/1000ml at 0.20ml/s with 34.4psi vacuum @11:23:42.85 -> SP.rate 0.235908909847862 @11:23:45.06 -> SP.rate 0.200020639519942 @11:23:46.89 -> SP.rate 0.226623133609169 @11:24:19.28 Cartridge 10 filtering 210/1000ml at 0.29ml/s with 29.1psi vacuum @11:25:19.28 Cartridge 10 filtering 223/1000ml at 0.20ml/s with 39.8psi vacuum @11:25:22.45 Flow averaged 0.37ml/s over 10:06 @11:25:22.53 Waiting up to 35 seconds for vacuum to reduce from 36.9 to 18.0psi @11:25:23.13 Relieved excess vacuum in .7 seconds @11:25:23.20 SamplePump.seek 1000ml,1:05:11 @11:25:29.73 Flow estimate reduced to 0.30ml/s @11:25:29.80 Waiting up to 12 seconds for vacuum to reduce from 27.6 to 18.0psi @11:25:30.41 Relieved excess vacuum in .7 seconds @11:25:30.46 SamplePump.seek 1000ml,1:05:04 @11:25:36.04 Flow estimate reduced to 0.24ml/s @11:25:36.12 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @11:25:36.72 Relieved excess vacuum in .7 seconds @11:25:36.77 SamplePump.seek 1000ml,1:04:59 @11:25:40.09 Flow estimate reduced to 0.19ml/s @11:25:40.12 Intake.close @11:25:40.20 Exhaust.close @11:25:40.57 Toroid.in :hold @11:25:40.68 Toroid.seek :bypass @11:25:42.36 Toroid.in :default @11:25:42.47 Toroid.seek :clear @11:25:44.12 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @11:25:44.15 Pressure.stop @11:25:44.44 Sampled 226.9ml @11:25:45.75 Plunge.seek :reagent @11:25:46.68 Sample loop closed. Ready to Deliver Reagents @11:25:46.71 Archive.seek :sealed @11:25:50.39 Archive.seek :evac @11:26:04.38 delay 1:00 @11:27:04.42 Archive.seek :clear @11:27:21.56 Sample preserved. Puck Full. :PROCESSED @11:28:41.03 -> BACsampler.prime nil, 300 @11:28:41.16 Priming bypass w/300ml @11:28:41.18 SamplePump.setPosition! 0ml @11:28:41.28 Bypass.open @11:28:42.81 Intake.open @11:28:44.39 Pressure.in :default @11:28:44.49 Pressure.hold @11:28:44.75 SamplePump.in :prime @11:28:44.85 SamplePump.seek 300ml,14:47 @11:30:55.76 -> SP Sample Pump (SP) at 142.33ml @11:32:48.44 SamplePump.hold @11:32:48.63 SamplePump.stop @11:32:48.72 Intake.close @11:32:48.78 Bypass.close @11:32:49.54 Pressure.stop @11:32:49.66 UserAbort in brent -- Sample Pump (SP) seek to 300ml Aborted! @11:33:07.08 -> Sea 0.6m deep @11:33:14.25 -> Leak Absolute Pressure (Leak) Sensor @14.2psia @11:37:27.35 -> showlog 50 @11:25:23.13 Relieved excess vacuum in .7 seconds @11:25:23.20 SamplePump.seek 1000ml,1:05:11 @11:25:29.73 Flow estimate reduced to 0.30ml/s @11:25:29.80 Waiting up to 12 seconds for vacuum to reduce from 27.6 to 18.0psi @11:25:30.41 Relieved excess vacuum in .7 seconds @11:25:30.46 SamplePump.seek 1000ml,1:05:04 @11:25:36.04 Flow estimate reduced to 0.24ml/s @11:25:36.12 Waiting up to 10 seconds for vacuum to reduce from 26.9 to 18.0psi @11:25:36.72 Relieved excess vacuum in .7 seconds @11:25:36.77 SamplePump.seek 1000ml,1:04:59 @11:25:40.09 Flow estimate reduced to 0.19ml/s @11:25:40.12 Intake.close @11:25:40.20 Exhaust.close @11:25:40.57 Toroid.in :hold @11:25:40.68 Toroid.seek :bypass @11:25:42.36 Toroid.in :default @11:25:42.47 Toroid.seek :clear @11:25:44.12 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @11:25:44.15 Pressure.stop @11:25:44.44 Sampled 226.9ml @11:25:45.75 Plunge.seek :reagent @11:25:46.68 Sample loop closed. Ready to Deliver Reagents @11:25:46.71 Archive.seek :sealed @11:25:50.39 Archive.seek :evac @11:26:04.38 delay 1:00 @11:27:04.42 Archive.seek :clear @11:27:21.56 Sample preserved. Puck Full. :PROCESSED @11:28:41.03 -> BACsampler.prime nil, 300 @11:28:41.16 Priming bypass w/300ml @11:28:41.18 SamplePump.setPosition! 0ml @11:28:41.28 Bypass.open @11:28:42.81 Intake.open @11:28:44.39 Pressure.in :default @11:28:44.49 Pressure.hold @11:28:44.75 SamplePump.in :prime @11:28:44.85 SamplePump.seek 300ml,14:47 @11:30:55.76 -> SP Sample Pump (SP) at 142.33ml @11:32:48.44 SamplePump.hold @11:32:48.63 SamplePump.stop @11:32:48.72 Intake.close @11:32:48.78 Bypass.close @11:32:49.54 Pressure.stop @11:32:49.66 UserAbort in brent -- Sample Pump (SP) seek to 300ml Aborted! @11:33:07.08 -> Sea 0.6m deep @11:33:14.25 -> Leak Absolute Pressure (Leak) Sensor @14.2psia @11:37:27.35 -> showlog 50 @11:38:26.06 -> Cmd.runCartridge @11:38:26.10 Selecting Cartridge 9 @11:38:26.36 Carousel.in :default @11:38:26.55 Carousel.home.seek 10 @11:38:27.04 Air.in :unlocking @11:38:27.24 Air.seek :clear @11:38:28.73 Lysis1.in :unlocking @11:38:28.95 Lysis1.seek :clear @11:38:29.02 Plunge.in :unlocking @11:38:29.21 Plunge.seek :clear @11:38:30.46 Carousel.seek 9 @11:38:31.60 Lysis1.in :fast @11:38:31.76 Lysis1.seek :locked @11:38:34.66 Plunge.in :default @11:38:34.84 Plunge.seek :locked @11:38:34.99 Air.in :fast @11:38:35.11 Air.seek :locked @11:38:36.70 Carousel.reconfigure :locked @11:38:36.82 Carousel.jog 0 @11:38:37.54 Mounted archive Cartridge @11:38:37.95 Preparing to filter cartridge 9 @11:38:38.31 Priming sample loop w/100ml, bypass w/10ml @11:38:38.33 SamplePump.setPosition! 0ml @11:38:38.46 Bypass.open @11:38:39.87 Intake.open @11:38:40.62 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @11:38:43.21 Vacuum tare is 20% of full scale @11:38:43.46 Sea pressure (Abs) tare is 10% of full scale @11:38:43.67 Pressure.in :default @11:38:43.78 Pressure.hold @11:38:44.06 SamplePump.in :prime @11:38:44.18 SamplePump.seek 10ml,59 seconds @11:38:53.78 Pressure.stop @11:38:53.88 SamplePump.setPosition! 0ml @11:38:53.97 Exhaust.open @11:38:55.32 Bypass.close @11:38:56.98 Pressure.in :default @11:38:57.10 Pressure.hold @11:38:57.56 SamplePump.in :prime @11:38:57.69 SamplePump.seek 100ml,5:16 @11:40:31.25 Pressure.stop @11:40:31.39 Bypass.open @11:40:32.04 Intake.close @11:40:32.79 Toroid.in :hold @11:40:32.91 Toroid.seek :crack @11:40:34.49 Toroid.seek :cartridge @11:40:35.47 Toroid.in :default @11:40:35.60 Toroid.seek :clear @11:40:38.21 Pressurizing cartridge to 26psi above 14.4psia @11:40:38.23 SamplePump.setPosition! 0ml @11:40:38.35 Intake.open @11:40:39.03 Bypass.close @11:40:39.68 Exhaust.close @11:40:40.57 Pressure.in :default @11:40:40.67 Pressure.hold @11:40:40.96 SamplePump.in :charge @11:40:41.08 SamplePump.seek 2.3ml,42 seconds @11:40:50.74 Pressure.stop @11:40:50.86 Intake.close @11:40:51.69 Pressurized cartridge with 0.445ml to 26.0psi @11:40:51.72 Isolated @29.9psia (15.5psi) @11:40:51.77 Verifying cartridge holds at least 0.65..0.85 of 29.9psia @11:40:51.87 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @11:40:55.11 -> hidelog Log display suppressed @11:40:56.20 Toroid.in :hold @11:40:56.30 Toroid.seek :bypass @11:40:57.97 Toroid.in :default @11:40:58.07 Toroid.seek :clear @11:40:59.82 Cartridge::Sampler::Leaky in FILTERING -- Isolated cartridge pressure fell by 36% to 19.1psia @11:40:59.84 Waiting to Resume from Checkpoint "Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi" @11:41:15.08 Cmd::Error in brent -- Not Filtering @11:41:15.13 UserAbort in brent -- User Abort!! @11:41:28.50 UserAbort in brent -- User Abort!! @11:41:39.27 -> slot {8..1 => { Type: :aRNAl_bac, State: :dry}, 9 => { Type: :aRNAl_bac, State: :leaky}, 10 => { Type: :aRNAl_bac, State: :processed, filtered: 226.9}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @11:41:45.04 -> slot 9=>:dry {9 => { Type: :aRNAl_bac, State: :dry}} @11:41:48.87 -> Cmd.runCartridge @11:41:48.91 Selecting Cartridge 9 @11:41:49.67 Preparing to filter cartridge 9 @11:41:49.98 Bypass.open @11:41:50.70 Toroid.in :hold @11:41:50.80 Toroid.seek :crack @11:41:52.37 Toroid.seek :cartridge @11:41:53.38 Toroid.in :default @11:41:53.48 Toroid.seek :clear @11:41:55.16 Exhaust.open @11:41:56.71 Pressurizing cartridge to 26psi above 14.3psia @11:41:56.73 SamplePump.setPosition! 0ml @11:41:56.82 Intake.open @11:41:57.49 Bypass.close @11:41:58.17 Exhaust.close @11:41:59.08 Pressure.in :default @11:41:59.18 Pressure.hold @11:41:59.48 SamplePump.seek 2.3ml,42 seconds @11:42:06.68 Pressure.stop @11:42:06.77 Intake.close @11:42:07.60 Pressurized cartridge with 0.247ml to 26.1psi @11:42:07.62 Isolated @35.5psia (21.1psi) @11:42:07.66 Verifying cartridge holds at least 0.65..0.85 of 35.5psia @11:42:07.71 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @11:42:12.41 Cartridge pressure fell 8% to 32.7psia @11:42:12.56 Sampling 1000.0ml in 1:25:20 @11:42:12.59 SamplePump.setPosition! 0ml @11:42:12.67 Exhaust.open @11:42:13.39 Intake.open @11:42:14.28 Pressure.in :default @11:42:14.38 Pressure.hold @11:42:14.79 SamplePump.in :sample @11:42:14.90 SamplePump.seek 1000ml,1:23:50 @11:42:17.27 Cartridge 9 filtering 1/1000ml at 0.52ml/s with 16.8psi vacuum @11:43:17.25 Cartridge 9 filtering 34/1000ml at 0.60ml/s with 14.8psi vacuum 8.2m deep (26.8psia) @11:44:17.27 Cartridge 9 filtering 66/1000ml at 0.56ml/s with 16.3psi vacuum @11:45:17.32 Cartridge 9 filtering 94/1000ml at 0.41ml/s with 39.0psi vacuum @11:46:17.27 Cartridge 9 filtering 119/1000ml at 0.49ml/s with 18.5psi vacuum 8.9m deep (27.9psia) @11:47:17.26 Cartridge 9 filtering 139/1000ml at 0.39ml/s with 14.7psi vacuum 2.7m deep (18.7psia) @11:48:17.27 Cartridge 9 filtering 158/1000ml at 0.20ml/s with 35.3psi vacuum @11:49:17.26 Cartridge 9 filtering 174/1000ml at 0.23ml/s with 27.4psi vacuum @11:50:17.85 Cartridge 9 filtering 189/1000ml at 0.20ml/s with 24.1psi vacuum @11:50:28.47 Flow averaged 0.39ml/s over 8:14 @11:50:28.54 Waiting up to 19 seconds for vacuum to reduce from 30.3 to 18.0psi @11:50:29.14 Relieved excess vacuum in .7 seconds @11:50:29.20 SamplePump.seek 1000ml,1:07:54 @11:50:40.87 Flow averaged 0.23ml/s over 12 seconds @11:50:40.94 Waiting up to 19 seconds for vacuum to reduce from 30.4 to 18.0psi @11:50:41.54 Relieved excess vacuum in .7 seconds @11:50:41.60 SamplePump.seek 1000ml,1:07:41 @11:50:49.58 Flow estimate reduced to 0.18ml/s @11:50:49.60 Intake.close @11:50:49.72 Exhaust.close @11:50:50.01 Toroid.in :hold @11:50:50.12 Toroid.seek :bypass @11:50:51.81 Toroid.in :default @11:50:51.91 Toroid.seek :clear @11:50:53.55 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @11:50:53.58 Pressure.stop @11:50:53.85 Sampled 195.5ml @11:50:54.51 Plunge.seek :reagent @11:50:55.40 Session Ended @11:50:55.55 Sample loop closed. Ready to Deliver Reagents @11:50:55.60 Archive.seek :sealed @11:50:59.27 Archive.seek :evac @11:51:13.27 delay 1:00 @11:52:13.30 Archive.seek :clear @11:52:30.48 Sample preserved. Puck Full. :PROCESSED @11:53:48.35 Session Begun @11:53:53.82 -> hidelog Log display suppressed @11:56:14.71 -> BACsampler.maxRate @11:56:14.73 NoMethodError in brent -- undefined method `maxRate' for BACsampler:Cartridge::Sampler @11:56:20.38 -> BACsampler.maxFlow 1.0 @11:56:38.49 -> BACsampler.maxFlow=0.5 0.5 @11:57:08.33 -> BACsampler.prime 100,nil @11:57:08.46 Priming sample loop w/100ml @11:57:08.49 SamplePump.setPosition! 0ml @11:57:08.58 Bypass.open @11:57:10.16 Exhaust.open @11:57:11.50 Bypass.close @11:57:11.54 Intake.open @11:57:13.18 Pressure.in :default @11:57:13.27 Pressure.hold @11:57:13.72 SamplePump.in :prime @11:57:13.83 SamplePump.seek 100ml,5:16 @11:57:21.79 -> Sampler.PSI 46.4196473606667 @11:57:23.70 -> Sampler.PSI 40.2030838386667 @11:57:25.29 -> Sampler.PSI 21.0340772116667 @11:57:28.82 -> Sampler.PSI 50.7279908696667 @11:57:31.21 -> Sampler.PSI 22.9255450936667 @11:57:34.47 SamplePump.hold @11:57:34.79 SamplePump.stop @11:57:34.89 Intake.close @11:57:34.96 Exhaust.close @11:57:35.70 Pressure.stop @11:57:35.80 UserAbort in brent -- Sample Pump (SP) seek to 100ml Aborted! @11:57:53.14 -> BACsampler.prime 100,nil @11:57:53.26 Priming sample loop w/100ml @11:57:53.28 SamplePump.setPosition! 0ml @11:57:53.42 Bypass.open @11:57:54.98 Exhaust.open @11:57:56.32 Bypass.close @11:57:56.36 Intake.open @11:57:57.97 Pressure.in :default @11:57:58.06 Pressure.hold @11:57:58.48 SamplePump.seek 100ml,5:16 @11:58:05.73 -> SP.rate 1.0236940885845 @11:58:12.84 SamplePump.hold @11:58:13.06 SamplePump.stop @11:58:13.16 Intake.close @11:58:13.24 Exhaust.close @11:58:14.15 Pressure.stop @11:58:14.25 UserAbort in brent -- Sample Pump (SP) seek to 100ml Aborted! @11:58:29.14 -> SP[:prime].maxSpeed 4325 @11:58:34.49 -> SP[:prime].maxSpeed=3500 3500 @11:58:45.04 -> SP[:sample].maxSpeed=3500 3500 @11:58:57.98 -> BACsampler.prime 100,nil @11:58:58.16 Priming sample loop w/100ml @11:58:58.19 SamplePump.setPosition! 0ml @11:58:58.28 Bypass.open @11:58:59.82 Exhaust.open @11:59:01.19 Bypass.close @11:59:01.27 Intake.open @11:59:02.90 Pressure.in :default @11:59:03.00 Pressure.hold @11:59:03.45 SamplePump.in :prime @11:59:03.56 SamplePump.seek 100ml,5:16 @11:59:08.03 -> SP.rate 0.87838423879523 @11:59:17.42 -> Sampler.PSI 24.4210535156667 @11:59:20.30 -> Sampler.PSI 27.3998869916667 @11:59:21.90 -> Sampler.PSI 21.5990809026667 @11:59:23.18 -> Sampler.PSI 44.2342557256667 @11:59:24.48 -> Sampler.PSI 32.9524569576667 @11:59:31.61 SamplePump.hold @11:59:32.36 SamplePump.stop @11:59:32.45 Intake.close @11:59:32.56 Exhaust.close @11:59:33.33 Pressure.stop @11:59:33.48 UserAbort in brent -- Sample Pump (SP) seek to 100ml Aborted! @11:59:51.30 -> SP[:prime].maxSpeed=2500 2500 @11:59:53.59 -> BACsampler.prime 100,nil @11:59:53.72 Priming sample loop w/100ml @11:59:53.74 SamplePump.setPosition! 0ml @11:59:53.83 Bypass.open @11:59:55.39 Exhaust.open @11:59:56.72 Bypass.close @11:59:56.79 Intake.open @11:59:58.37 Pressure.in :default @11:59:58.47 Pressure.hold @11:59:58.87 SamplePump.in :prime @11:59:58.98 SamplePump.seek 100ml,5:16 @12:00:05.14 -> Sampler.PSI 17.3288104186667 @12:00:06.76 -> Sampler.PSI 20.6076593316667 @12:00:08.62 SamplePump.stop @12:00:08.70 -> Sampler.PSI @12:00:08.78 Intake.close @12:00:08.89 Exhaust.close -0.525915385333334 @12:00:09.73 Pressure.stop @12:00:09.83 Cartridge::Sampler::Leaky in brent -- Serious Leak or Stall -- 0.63ml/s made only 12.0psi vacuum after 5.9ml @12:00:20.07 -> SP[:prime].maxSpeed=3000 3000 @12:00:23.37 -> BACsampler.prime 100,nil @12:00:23.51 Priming sample loop w/100ml @12:00:23.54 SamplePump.setPosition! 0ml @12:00:23.64 Bypass.open @12:00:25.21 Exhaust.open @12:00:26.58 Bypass.close @12:00:26.62 Intake.open @12:00:28.25 Pressure.in :default @12:00:28.35 Pressure.hold @12:00:28.38 -> Sampler.PSI 0.0192903326666638 @12:00:29.00 SamplePump.in :prime @12:00:29.11 SamplePump.seek 100ml,5:16 @12:00:31.42 -> Sampler.PSI 14.7459364026667 @12:00:33.11 -> Sampler.PSI 9.41266706066666 @12:00:34.93 -> Sampler.PSI 17.5298359906667 @12:00:36.50 -> Sampler.PSI 26.9536711386667 @12:00:38.42 -> Sampler.PSI 18.8182271566667 @12:00:40.02 -> Sampler.PSI 18.6583204516667 @12:00:41.94 -> Sampler.PSI 34.5469552446667 @12:00:43.86 -> Sampler.PSI 24.2657155736667 @12:00:48.74 SamplePump.hold @12:00:48.97 SamplePump.stop @12:00:49.07 Intake.close @12:00:49.18 Exhaust.close @12:00:50.05 Pressure.stop @12:00:50.15 UserAbort in brent -- Sample Pump (SP) seek to 100ml Aborted! @12:00:55.14 -> SP[:prime].maxSpeed=3500 3500 @12:01:07.86 -> Cmd.runCartridge @12:01:07.90 Selecting Cartridge 8 @12:01:08.10 Carousel.in :default @12:01:08.27 Carousel.home.seek 9 @12:01:08.76 Air.in :unlocking @12:01:08.90 Air.seek :clear @12:01:10.26 Lysis1.in :unlocking @12:01:10.48 Lysis1.seek :clear @12:01:10.55 Plunge.in :unlocking @12:01:10.70 Plunge.seek :clear @12:01:11.95 Carousel.seek 8 @12:01:13.01 Lysis1.in :fast @12:01:13.11 Lysis1.seek :locked @12:01:15.43 Plunge.in :default @12:01:15.59 Plunge.seek :locked @12:01:15.72 Air.in :fast @12:01:15.81 Air.seek :locked @12:01:17.41 Carousel.reconfigure :locked @12:01:17.51 Carousel.jog 0 @12:01:18.22 Mounted archive Cartridge @12:01:18.60 Preparing to filter cartridge 8 @12:01:18.95 Priming sample loop w/100ml, bypass w/10ml @12:01:18.98 SamplePump.setPosition! 0ml @12:01:19.06 Bypass.open @12:01:20.44 Intake.open @12:01:21.16 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @12:01:23.98 Vacuum tare is 20% of full scale @12:01:24.18 Sea pressure (Abs) tare is 10% of full scale @12:01:24.37 Pressure.in :default @12:01:24.47 Pressure.hold @12:01:24.75 SamplePump.in :prime @12:01:24.87 SamplePump.seek 10ml,59 seconds @12:01:36.53 Pressure.stop @12:01:36.63 SamplePump.setPosition! 0ml @12:01:36.71 Exhaust.open @12:01:38.09 Bypass.close @12:01:39.64 Pressure.in :default @12:01:39.74 Pressure.hold @12:01:40.14 SamplePump.in :prime @12:01:40.25 SamplePump.seek 100ml,5:16 @12:01:47.63 -> Sampler.PSI 32.351410803 @12:01:49.46 -> Sampler.PSI 32.263081385 @12:01:51.20 -> Sampler.PSI 51.450363064 @12:02:13.51 -> spLog=SP.log{delay 5};nil @12:02:13.65 delay 5 seconds @12:02:54.74 -> splog.map{|l| Sampler::DeltaSkew.apply l}.minmax @12:02:54.77 TypeError in bar -- :splog can't be coerced into Float @12:03:02.45 -> spLog.map{|l| Sampler::DeltaSkew.apply l}.minmax @12:03:02.49 TypeError in bar -- I2C::Servo::Status can't be coerced into Float @12:03:11.92 -> spLog.map{|l| Sampler::DeltaSkew.apply l.deltaPress}.minmax [9.85329887,52.661085259] @12:03:34.08 Pressure.stop @12:03:34.19 Bypass.open @12:03:34.81 Intake.close @12:03:35.59 Toroid.in :hold @12:03:35.69 Toroid.seek :crack @12:03:37.27 Toroid.seek :cartridge @12:03:38.92 Toroid.in :default @12:03:39.02 Toroid.seek :clear @12:03:41.05 Pressurizing cartridge to 26psi above 14.4psia @12:03:41.08 SamplePump.setPosition! 0ml @12:03:41.17 Intake.open @12:03:41.82 Bypass.close @12:03:42.46 Exhaust.close @12:03:43.34 Pressure.in :default @12:03:43.47 Pressure.hold @12:03:43.74 SamplePump.in :charge @12:03:43.84 SamplePump.seek 2.3ml,42 seconds @12:03:53.81 Pressure.stop @12:03:53.90 Intake.close @12:03:54.73 Pressurized cartridge with 0.477ml to 26.3psi @12:03:54.75 Isolated @37.7psia (23.3psi) @12:03:54.79 Verifying cartridge holds at least 0.65..0.85 of 37.7psia @12:03:54.84 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @12:03:59.54 Cartridge pressure fell 6% to 35.5psia @12:03:59.69 Sampling 1000.0ml in 1:25:20 @12:03:59.72 SamplePump.setPosition! 0ml @12:03:59.83 Exhaust.open @12:04:00.48 Intake.open @12:04:01.42 Pressure.in :default @12:04:01.52 Pressure.hold @12:04:01.77 Sea 4.5m deep (21.4psia) @12:04:01.98 SamplePump.in :sample @12:04:02.08 SamplePump.seek 1000ml,1:23:50 @12:04:04.37 Cartridge 8 filtering 1/1000ml at 0.49ml/s with 24.0psi vacuum @12:05:04.90 Cartridge 8 filtering 31/1000ml at 0.50ml/s with 18.8psi vacuum @12:05:19.39 -> spLog=SP.log{delay 5};nil @12:05:19.55 delay 5 seconds @12:05:28.81 -> spLog.map{|l| Sampler::DeltaSkew.apply l.deltaPress}.minmax [9.76192361,27.910573167] @12:06:04.38 Cartridge 8 filtering 61/1000ml at 0.50ml/s with 13.0psi vacuum @12:07:04.38 Cartridge 8 filtering 90/1000ml at 0.50ml/s with 18.1psi vacuum @12:08:04.38 Cartridge 8 filtering 117/1000ml at 0.34ml/s with 25.3psi vacuum @12:09:04.38 Cartridge 8 filtering 141/1000ml at 0.34ml/s with 18.2psi vacuum @12:10:04.38 Cartridge 8 filtering 162/1000ml at 0.41ml/s with 36.9psi vacuum 6.7m deep (24.6psia) @12:11:04.38 Cartridge 8 filtering 180/1000ml at 0.38ml/s with 20.5psi vacuum 5.9m deep (23.5psia) @12:12:04.40 Cartridge 8 filtering 196/1000ml at 0.22ml/s with 18.7psi vacuum @12:12:34.29 -> BACsampler.maxFlow 0.5 @12:12:40.66 -> BACsampler.maxFlow=0.8 0.8 @12:13:04.38 Cartridge 8 filtering 210/1000ml at 0.32ml/s with 23.6psi vacuum 1.9m deep (17.4psia) @12:13:37.84 Flow averaged 0.38ml/s over 9:36 @12:13:37.92 Waiting up to 23 seconds for vacuum to reduce from 32.2 to 18.0psi @12:13:38.52 Relieved excess vacuum in .7 seconds @12:13:38.58 SamplePump.seek 1000ml,1:05:41 @12:13:47.57 Flow averaged 0.22ml/s over 10 seconds @12:13:47.69 Waiting up to 39 seconds for vacuum to reduce from 38.2 to 18.0psi @12:13:48.30 Relieved excess vacuum in .7 seconds @12:13:48.35 SamplePump.seek 1000ml,1:05:31 @12:13:56.07 Flow estimate reduced to 0.17ml/s @12:13:56.10 Intake.close @12:13:56.23 Exhaust.close @12:13:56.50 Toroid.in :hold @12:13:56.60 Toroid.seek :bypass @12:13:58.28 Toroid.in :default @12:13:58.39 Toroid.seek :clear @12:14:00.04 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @12:14:00.67 Pressure.stop @12:14:01.06 Sampled 221.5ml @12:14:01.79 Plunge.seek :reagent @12:14:02.72 Sample loop closed. Ready to Deliver Reagents @12:14:02.75 Archive.seek :sealed @12:14:06.45 Archive.seek :evac @12:14:20.44 delay 1:00 @12:15:20.48 Archive.seek :clear @12:15:37.62 Sample preserved. Puck Full. :PROCESSED @12:17:17.73 -> slot {7..1 => { Type: :aRNAl_bac, State: :dry}, 8 => { Type: :aRNAl_bac, State: :processed, filtered: 221.5}, 9 => { Type: :aRNAl_bac, State: :processed, filtered: 195.5}, 10 => { Type: :aRNAl_bac, State: :processed, filtered: 226.9}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @12:17:32.68 -> Cmd.runCartridge @12:17:32.74 Selecting Cartridge 7 @12:17:32.93 Carousel.in :default @12:17:33.10 Carousel.home.seek 8 @12:17:33.59 Air.in :unlocking @12:17:33.78 Air.seek :clear @12:17:35.20 Lysis1.in :unlocking @12:17:35.43 Lysis1.seek :clear @12:17:35.50 Plunge.in :unlocking @12:17:35.67 Plunge.seek :clear @12:17:36.91 Carousel.seek 7 @12:17:38.05 Lysis1.in :fast @12:17:38.14 Lysis1.seek :locked @12:17:40.44 Plunge.in :default @12:17:40.58 Plunge.seek :locked @12:17:40.73 Air.in :fast @12:17:40.82 Air.seek :locked @12:17:42.39 Carousel.reconfigure :locked @12:17:42.50 Carousel.jog 0 @12:17:43.21 Mounted archive Cartridge @12:17:43.61 Preparing to filter cartridge 7 @12:17:43.98 Priming sample loop w/100ml, bypass w/10ml @12:17:44.63 SamplePump.setPosition! 0ml @12:17:44.72 Bypass.open @12:17:46.14 Intake.open @12:17:46.85 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @12:17:49.46 Vacuum tare is 20% of full scale @12:17:49.78 Sea pressure (Abs) tare is 10% of full scale @12:17:49.97 Pressure.in :default @12:17:50.06 Pressure.hold @12:17:50.33 SamplePump.in :prime @12:17:50.44 SamplePump.seek 10ml,59 seconds @12:18:02.09 Pressure.stop @12:18:02.18 SamplePump.setPosition! 0ml @12:18:02.26 Exhaust.open @12:18:03.63 Bypass.close @12:18:05.20 Pressure.in :default @12:18:05.30 Pressure.hold @12:18:05.74 SamplePump.in :prime @12:18:05.84 SamplePump.seek 100ml,5:16 @12:19:59.47 Pressure.stop @12:19:59.58 Bypass.open @12:20:00.21 Intake.close @12:20:00.95 Toroid.in :hold @12:20:01.05 Toroid.seek :crack @12:20:02.62 Toroid.seek :cartridge @12:20:03.60 Toroid.in :default @12:20:03.70 Toroid.seek :clear @12:20:05.77 Pressurizing cartridge to 26psi above 14.0psia @12:20:05.79 SamplePump.setPosition! 0ml @12:20:05.88 Intake.open @12:20:06.49 Bypass.close @12:20:07.12 Exhaust.close @12:20:07.99 Pressure.in :default @12:20:08.08 Pressure.hold @12:20:08.35 SamplePump.in :charge @12:20:09.08 SamplePump.seek 2.3ml,42 seconds @12:20:19.19 Pressure.stop @12:20:19.29 Intake.close @12:20:20.09 Pressurized cartridge with 0.489ml to 26.5psi @12:20:20.11 Isolated @36.5psia (22.5psi) @12:20:20.14 Verifying cartridge holds at least 0.65..0.85 of 36.5psia @12:20:20.20 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @12:20:24.89 Cartridge pressure fell 9% to 33.2psia @12:20:25.02 Sampling 1000.0ml in 1:25:20 @12:20:25.05 SamplePump.setPosition! 0ml @12:20:25.15 Exhaust.open @12:20:25.79 Intake.open @12:20:26.71 Pressure.in :default @12:20:26.80 Pressure.hold @12:20:27.04 Sea 2.2m deep (18.0psia) @12:20:27.25 SamplePump.in :sample @12:20:27.40 SamplePump.seek 1000ml,1:23:50 @12:20:29.70 Cartridge 7 filtering 1/1000ml at 0.68ml/s with 18.4psi vacuum 4.1m deep (20.8psia) @12:20:44.88 -> slot {6..1 => { Type: :aRNAl_bac, State: :dry}, 7 => { Type: :aRNAl_bac, State: :filtering, TV: :open}, 8 => { Type: :aRNAl_bac, State: :processed, filtered: 221.5}, 9 => { Type: :aRNAl_bac, State: :processed, filtered: 195.5}, 10 => { Type: :aRNAl_bac, State: :processed, filtered: 226.9}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @12:20:51.00 -> Cartridge.dry [1,2,3,4,5,6] @12:21:29.70 Cartridge 7 filtering 36/1000ml at 0.58ml/s with 12.2psi vacuum @12:22:29.69 Cartridge 7 filtering 70/1000ml at 0.51ml/s with 24.1psi vacuum @12:23:29.69 Cartridge 7 filtering 101/1000ml at 0.46ml/s with 11.0psi vacuum @12:24:29.69 Cartridge 7 filtering 127/1000ml at 0.47ml/s with 14.4psi vacuum @12:25:29.69 Cartridge 7 filtering 150/1000ml at 0.36ml/s with 18.8psi vacuum @12:26:29.76 Cartridge 7 filtering 170/1000ml at 0.32ml/s with 20.2psi vacuum 1.6m deep (17.1psia) @12:27:29.69 Cartridge 7 filtering 187/1000ml at 0.39ml/s with 21.1psi vacuum 11.8m deep (32.1psia) @12:28:29.70 Cartridge 7 filtering 203/1000ml at 0.36ml/s with 19.5psi vacuum 13.5m deep (34.6psia) @12:29:29.69 Cartridge 7 filtering 218/1000ml at 0.32ml/s with 25.9psi vacuum @12:30:13.44 Flow averaged 0.39ml/s over 9:47 @12:30:13.51 Waiting up to 12 seconds for vacuum to reduce from 27.6 to 18.0psi @12:30:14.57 Relieved excess vacuum in 1.1 seconds @12:30:14.63 SamplePump.seek 1000ml,1:04:51 @12:30:25.97 Flow averaged 0.22ml/s over 12 seconds @12:30:26.05 Waiting up to 15 seconds for vacuum to reduce from 29.0 to 18.0psi @12:30:26.66 Relieved excess vacuum in .7 seconds @12:30:26.70 SamplePump.seek 1000ml,1:04:39 @12:30:29.70 Cartridge 7 filtering 231/1000ml at 0.20ml/s with 45.7psi vacuum @12:30:32.77 Flow estimate reduced to 0.18ml/s @12:30:32.80 Intake.close @12:30:32.92 Exhaust.close @12:30:33.38 Toroid.in :hold @12:30:33.49 Toroid.seek :bypass @12:30:35.19 Toroid.in :default @12:30:35.29 Toroid.seek :clear @12:30:36.97 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @12:30:36.99 Pressure.stop @12:30:37.29 Sampled 231.6ml @12:30:38.00 Plunge.seek :reagent @12:30:38.93 Sample loop closed. Ready to Deliver Reagents @12:30:38.96 Archive.seek :sealed @12:30:42.64 Archive.seek :evac @12:30:56.63 delay 1:00 @12:31:56.67 Archive.seek :clear @12:32:13.79 Sample preserved. Puck Full. :PROCESSED @12:37:04.23 -> Cmd.runCartridge @12:37:04.28 Selecting Cartridge 6 @12:37:04.46 Carousel.in :default @12:37:04.61 Carousel.home.seek 7 @12:37:05.08 Air.in :unlocking @12:37:05.27 Air.seek :clear @12:37:06.74 Lysis1.in :unlocking @12:37:06.94 Lysis1.seek :clear @12:37:07.04 Plunge.in :unlocking @12:37:07.17 Plunge.seek :clear @12:37:08.41 Carousel.seek 6 @12:37:10.11 Lysis1.in :fast @12:37:10.22 Lysis1.seek :locked @12:37:12.52 Plunge.in :default @12:37:12.64 Plunge.seek :locked @12:37:12.82 Air.in :fast @12:37:12.92 Air.seek :locked @12:37:14.50 Carousel.reconfigure :locked @12:37:14.60 Carousel.jog 0 @12:37:15.33 Mounted archive Cartridge @12:37:15.74 Preparing to filter cartridge 6 @12:37:16.10 Priming sample loop w/100ml, bypass w/10ml @12:37:16.13 SamplePump.setPosition! 0ml @12:37:16.22 Bypass.open @12:37:17.63 Intake.open @12:37:18.33 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @12:37:20.93 Vacuum tare is 20% of full scale @12:37:21.13 Sea pressure (Abs) tare is 10% of full scale @12:37:21.36 Pressure.in :default @12:37:21.47 Pressure.hold @12:37:21.73 SamplePump.in :prime @12:37:21.84 SamplePump.seek 10ml,59 seconds @12:37:33.48 Pressure.stop @12:37:33.56 SamplePump.setPosition! 0ml @12:37:33.64 Exhaust.open @12:37:34.97 Bypass.close @12:37:36.51 Pressure.in :default @12:37:36.61 Pressure.hold @12:37:37.03 SamplePump.in :prime @12:37:37.13 SamplePump.seek 100ml,5:16 @12:39:30.71 Pressure.stop @12:39:30.82 Bypass.open @12:39:31.42 Intake.close @12:39:32.15 Toroid.in :hold @12:39:32.25 Toroid.seek :crack @12:39:34.42 Toroid.seek :cartridge @12:39:35.44 Toroid.in :default @12:39:35.53 Toroid.seek :clear @12:39:37.59 Pressurizing cartridge to 26psi above 14.4psia @12:39:37.61 SamplePump.setPosition! 0ml @12:39:37.71 Intake.open @12:39:38.36 Bypass.close @12:39:39.01 Exhaust.close @12:39:39.89 Pressure.in :default @12:39:39.99 Pressure.hold @12:39:40.25 SamplePump.in :charge @12:39:40.36 SamplePump.seek 2.3ml,42 seconds @12:39:50.41 Pressure.stop @12:39:50.50 Intake.close @12:39:51.27 Pressurized cartridge with 0.486ml to 26.1psi @12:39:51.28 Isolated @33.9psia (19.5psi) @12:39:51.31 Verifying cartridge holds at least 0.65..0.85 of 33.9psia @12:39:51.42 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @12:39:56.10 Cartridge pressure fell 1% to 33.4psia @12:39:56.24 Sampling 1000.0ml in 1:25:20 @12:39:56.27 SamplePump.setPosition! 0ml @12:39:56.36 Exhaust.open @12:39:57.01 Intake.open @12:39:57.86 Pressure.in :default @12:39:57.96 Pressure.hold @12:39:58.21 Sea 3.0m deep (19.1psia) @12:39:58.41 SamplePump.in :sample @12:39:58.52 SamplePump.seek 1000ml,1:23:50 @12:40:01.52 Cartridge 6 filtering 1/1000ml at 0.71ml/s with 21.6psi vacuum 7.7m deep (26.0psia) @12:41:00.86 Cartridge 6 filtering 37/1000ml at 0.56ml/s with 10.0psi vacuum @12:42:00.86 Cartridge 6 filtering 71/1000ml at 0.54ml/s with 24.7psi vacuum @12:43:00.86 Cartridge 6 filtering 105/1000ml at 0.50ml/s with 24.9psi vacuum @12:44:00.86 Cartridge 6 filtering 136/1000ml at 0.53ml/s with 15.8psi vacuum @12:45:00.86 Cartridge 6 filtering 164/1000ml at 0.41ml/s with 21.2psi vacuum @12:46:00.85 Cartridge 6 filtering 189/1000ml at 0.39ml/s with 20.6psi vacuum @12:47:00.85 Cartridge 6 filtering 212/1000ml at 0.25ml/s with 33.3psi vacuum @12:48:00.86 Cartridge 6 filtering 232/1000ml at 0.33ml/s with 23.6psi vacuum @12:49:00.86 Cartridge 6 filtering 250/1000ml at 0.34ml/s with 10.7psi vacuum 3.4m deep (19.7psia) @12:50:00.86 Cartridge 6 filtering 267/1000ml at 0.27ml/s with 28.0psi vacuum @12:51:00.85 Cartridge 6 filtering 283/1000ml at 0.22ml/s with 17.3psi vacuum @12:52:00.85 Cartridge 6 filtering 298/1000ml at 0.28ml/s with 40.3psi vacuum 2.4m deep (18.3psia) @12:53:00.86 Cartridge 6 filtering 312/1000ml at 0.26ml/s with 11.1psi vacuum 1.8m deep (17.4psia) @12:53:17.30 Flow averaged 0.39ml/s over 13:19 @12:53:17.40 Waiting up to 17 seconds for vacuum to reduce from 29.4 to 18.0psi @12:53:18.01 Relieved excess vacuum in .7 seconds @12:53:18.07 SamplePump.seek 1000ml,57:33 @12:53:29.90 Flow averaged 0.22ml/s over 12 seconds @12:53:29.97 Waiting up to 16 seconds for vacuum to reduce from 29.2 to 18.0psi @12:53:30.57 Relieved excess vacuum in .7 seconds @12:53:30.63 SamplePump.seek 1000ml,57:19 @12:53:40.15 Flow averaged 0.22ml/s over 10 seconds @12:53:40.22 Waiting up to 14 seconds for vacuum to reduce from 28.4 to 18.0psi @12:53:40.84 Relieved excess vacuum in .7 seconds @12:53:40.90 SamplePump.seek 1000ml,57:09 @12:53:48.51 Flow estimate reduced to 0.17ml/s @12:53:48.55 Intake.close @12:53:48.63 Exhaust.close @12:53:48.99 Toroid.in :hold @12:53:49.10 Toroid.seek :bypass @12:53:50.79 Toroid.in :default @12:53:50.90 Toroid.seek :clear @12:53:52.55 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @12:53:52.58 Pressure.stop @12:53:52.87 Sampled 321.9ml @12:53:53.58 Plunge.seek :reagent @12:53:55.13 Sample loop closed. Ready to Deliver Reagents @12:53:55.16 Archive.seek :sealed @12:53:58.87 Archive.seek :evac @12:54:12.86 delay 1:00 @12:55:12.89 Archive.seek :clear @12:55:30.04 Sample preserved. Puck Full. :PROCESSED @12:55:49.28 -> Cmd.runCartridge @12:55:49.33 Selecting Cartridge 5 @12:55:49.56 Carousel.in :default @12:55:49.73 Carousel.home.seek 6 @12:55:50.18 Air.in :unlocking @12:55:50.34 Air.seek :clear @12:55:51.70 Lysis1.in :unlocking @12:55:51.90 Lysis1.seek :clear @12:55:51.94 Plunge.in :unlocking @12:55:52.11 Plunge.seek :clear @12:55:53.38 Carousel.seek 5 @12:55:54.47 Lysis1.in :fast @12:55:54.57 Lysis1.seek :locked @12:55:56.85 Plunge.in :default @12:55:56.98 Plunge.seek :locked @12:55:57.16 Air.in :fast @12:55:57.26 Air.seek :locked @12:55:58.83 Carousel.reconfigure :locked @12:55:58.93 Carousel.jog 0 @12:55:59.64 Mounted archive Cartridge @12:56:00.04 Preparing to filter cartridge 5 @12:56:00.40 Priming sample loop w/100ml, bypass w/10ml @12:56:00.43 SamplePump.setPosition! 0ml @12:56:00.53 Bypass.open @12:56:01.94 Intake.open @12:56:02.62 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @12:56:05.46 Vacuum tare is 21% of full scale @12:56:05.66 Sea pressure (Abs) tare is 10% of full scale @12:56:05.86 Pressure.in :default @12:56:05.96 Pressure.hold @12:56:06.24 SamplePump.in :prime @12:56:06.34 SamplePump.seek 10ml,59 seconds @12:56:18.00 Pressure.stop @12:56:18.08 SamplePump.setPosition! 0ml @12:56:18.17 Exhaust.open @12:56:19.50 Bypass.close @12:56:21.05 Pressure.in :default @12:56:21.15 Pressure.hold @12:56:21.60 SamplePump.in :prime @12:56:21.71 SamplePump.seek 100ml,5:16 @12:58:00.59 -> SP Sample Pump (SP) at 87.03ml @12:58:15.40 Pressure.stop @12:58:15.51 Bypass.open @12:58:16.12 Intake.close @12:58:16.84 Toroid.in :hold @12:58:16.93 Toroid.seek :crack @12:58:18.50 Toroid.seek :cartridge @12:58:19.48 Toroid.in :default @12:58:19.58 Toroid.seek :clear @12:58:21.63 Pressurizing cartridge to 26psi above 14.2psia @12:58:21.65 SamplePump.setPosition! 0ml @12:58:21.74 Intake.open @12:58:22.39 Bypass.close @12:58:23.03 Exhaust.close @12:58:23.89 Pressure.in :default @12:58:23.98 Pressure.hold @12:58:24.25 SamplePump.in :charge @12:58:24.36 SamplePump.seek 2.3ml,42 seconds @12:58:34.28 Pressure.stop @12:58:34.36 Intake.close @12:58:35.16 Pressurized cartridge with 0.471ml to 26.0psi @12:58:35.18 Isolated @38.5psia (24.3psi) @12:58:35.22 Verifying cartridge holds at least 0.65..0.85 of 38.5psia @12:58:35.27 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @12:58:39.96 Cartridge pressure fell 1% to 38.3psia @12:58:40.08 Sampling 1000.0ml in 1:25:20 @12:58:40.11 SamplePump.setPosition! 0ml @12:58:40.21 Exhaust.open @12:58:40.82 Intake.open @12:58:41.72 Pressure.in :default @12:58:41.82 Pressure.hold @12:58:42.24 SamplePump.in :sample @12:58:42.35 SamplePump.seek 1000ml,1:23:50 @12:58:44.70 Cartridge 5 filtering 1/1000ml at 0.60ml/s with 26.0psi vacuum @12:59:44.71 Cartridge 5 filtering 37/1000ml at 0.65ml/s with 17.5psi vacuum 8.4m deep (27.1psia) @13:00:44.71 Cartridge 5 filtering 73/1000ml at 0.56ml/s with 25.7psi vacuum @13:01:44.71 Cartridge 5 filtering 108/1000ml at 0.61ml/s with 32.8psi vacuum @13:02:44.71 Cartridge 5 filtering 141/1000ml at 0.57ml/s with 35.3psi vacuum @13:03:44.71 Cartridge 5 filtering 172/1000ml at 0.51ml/s with 7.6psi vacuum 3.2m deep (19.5psia) @13:04:44.71 Cartridge 5 filtering 201/1000ml at 0.53ml/s with 13.0psi vacuum 6.6m deep (24.4psia) @13:05:44.71 Cartridge 5 filtering 228/1000ml at 0.45ml/s with 7.4psi vacuum 3.9m deep (20.4psia) @13:06:44.71 Cartridge 5 filtering 252/1000ml at 0.37ml/s with 21.7psi vacuum @13:07:44.71 Cartridge 5 filtering 274/1000ml at 0.41ml/s with 9.7psi vacuum 4.2m deep (20.9psia) @13:08:44.71 Cartridge 5 filtering 294/1000ml at 0.30ml/s with 17.8psi vacuum 2.3m deep (18.1psia) @13:09:44.71 Cartridge 5 filtering 313/1000ml at 0.41ml/s with 18.3psi vacuum 3.4m deep (19.7psia) @13:10:44.70 Cartridge 5 filtering 330/1000ml at 0.25ml/s with 24.0psi vacuum @13:11:44.71 Cartridge 5 filtering 346/1000ml at 0.25ml/s with 12.5psi vacuum @13:12:44.71 Cartridge 5 filtering 362/1000ml at 0.27ml/s with 8.9psi vacuum 1.8m deep (17.4psia) @13:13:44.71 Cartridge 5 filtering 376/1000ml at 0.20ml/s with 23.6psi vacuum @13:14:44.70 Cartridge 5 filtering 390/1000ml at 0.20ml/s with 44.5psi vacuum @13:14:51.65 Flow averaged 0.40ml/s over 16:10 @13:14:51.72 Waiting up to 14 seconds for vacuum to reduce from 28.6 to 18.0psi @13:14:52.33 Relieved excess vacuum in .7 seconds @13:14:52.38 SamplePump.seek 1000ml,51:13 @13:14:58.41 Flow estimate reduced to 0.32ml/s @13:14:58.48 Waiting up to 15 seconds for vacuum to reduce from 28.8 to 18.0psi @13:14:59.10 Relieved excess vacuum in .7 seconds @13:14:59.14 SamplePump.seek 1000ml,51:06 @13:15:05.16 Flow estimate reduced to 0.26ml/s @13:15:05.24 Waiting up to 16 seconds for vacuum to reduce from 29.0 to 18.0psi @13:15:05.85 Relieved excess vacuum in .7 seconds @13:15:05.89 SamplePump.seek 1000ml,51:00 @13:15:11.46 Flow estimate reduced to 0.21ml/s @13:15:11.53 Waiting up to 25 seconds for vacuum to reduce from 33.0 to 18.0psi @13:15:12.15 Relieved excess vacuum in .7 seconds @13:15:12.21 SamplePump.seek 1000ml,50:53 @13:15:17.30 Flow estimate reduced to 0.17ml/s @13:15:17.34 Intake.close @13:15:17.46 Exhaust.close @13:15:17.83 Toroid.in :hold @13:15:17.93 Toroid.seek :bypass @13:15:19.62 Toroid.in :default @13:15:19.72 Toroid.seek :clear @13:15:21.39 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @13:15:21.42 Pressure.stop @13:15:21.72 Sampled 396.4ml @13:15:22.41 Plunge.seek :reagent @13:15:23.35 Sample loop closed. Ready to Deliver Reagents @13:15:23.40 Archive.seek :sealed @13:15:27.10 Archive.seek :evac @13:15:41.10 delay 1:00 @13:16:41.13 Archive.seek :clear @13:16:58.28 Sample preserved. Puck Full. :PROCESSED @14:00:04.18 -> Cmd.runCartridge @14:00:04.22 Selecting Cartridge 4 @14:00:04.42 Carousel.in :default @14:00:04.57 Carousel.home.seek 5 @14:00:05.04 Air.in :unlocking @14:00:05.21 Air.seek :clear @14:00:07.27 Lysis1.in :unlocking @14:00:07.49 Lysis1.seek :clear @14:00:07.59 Plunge.in :unlocking @14:00:07.69 Plunge.seek :clear @14:00:08.93 Carousel.seek 4 @14:00:10.02 Lysis1.in :fast @14:00:10.12 Lysis1.seek :locked @14:00:12.40 Plunge.in :default @14:00:12.54 Plunge.seek :locked @14:00:12.67 Air.in :fast @14:00:12.76 Air.seek :locked @14:00:14.33 Carousel.reconfigure :locked @14:00:14.44 Carousel.jog 0 @14:00:15.14 Mounted archive Cartridge @14:00:15.54 Preparing to filter cartridge 4 @14:00:15.88 Priming sample loop w/100ml, bypass w/10ml @14:00:15.90 SamplePump.setPosition! 0ml @14:00:15.99 Bypass.open @14:00:17.41 Intake.open @14:00:18.14 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @14:00:20.74 Vacuum tare is 20% of full scale @14:00:20.92 Sea pressure (Abs) tare is 10% of full scale @14:00:21.11 Pressure.in :default @14:00:21.20 Pressure.hold @14:00:21.48 SamplePump.in :prime @14:00:21.59 SamplePump.seek 10ml,59 seconds @14:00:33.24 Pressure.stop @14:00:33.32 SamplePump.setPosition! 0ml @14:00:33.43 Exhaust.open @14:00:34.78 Bypass.close @14:00:36.92 Pressure.in :default @14:00:37.02 Pressure.hold @14:00:37.44 SamplePump.in :prime @14:00:37.54 SamplePump.seek 100ml,5:16 @14:02:31.15 Pressure.stop @14:02:31.26 Bypass.open @14:02:31.87 Intake.close @14:02:32.60 Toroid.in :hold @14:02:32.70 Toroid.seek :crack @14:02:34.27 Toroid.seek :cartridge @14:02:35.24 Toroid.in :default @14:02:35.34 Toroid.seek :clear @14:02:37.41 Pressurizing cartridge to 26psi above 14.5psia @14:02:37.44 SamplePump.setPosition! 0ml @14:02:37.52 Intake.open @14:02:38.20 Bypass.close @14:02:38.84 Exhaust.close @14:02:39.68 Pressure.in :default @14:02:39.77 Pressure.hold @14:02:40.02 SamplePump.in :charge @14:02:40.13 SamplePump.seek 2.3ml,42 seconds @14:02:50.46 Pressure.stop @14:02:50.61 Intake.close @14:02:51.45 Pressurized cartridge with 0.512ml to 26.7psi @14:02:51.47 Isolated @38.5psia (24.0psi) @14:02:51.51 Verifying cartridge holds at least 0.65..0.85 of 38.5psia @14:02:51.56 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @14:03:01.29 Cartridge pressure fell 27% to 27.9psia @14:03:01.48 Toroid.in :hold @14:03:01.58 Toroid.seek :bypass @14:03:03.26 Toroid.in :default @14:03:03.37 Toroid.seek :clear @14:03:05.13 Cartridge::Sampler::Leaky in FILTERING -- Retained only 27.9psia @14:03:05.15 Waiting to Resume from Checkpoint "Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi" @14:03:20.56 Cmd::Error in brent -- Not Filtering @14:03:20.62 UserAbort in brent -- User Abort!! @14:03:28.93 -> slot {3..1 => { Type: :aRNAl_bac, State: :dry}, 4 => { Type: :aRNAl_bac, State: :leaky}, 5 => { Type: :aRNAl_bac, State: :processed, filtered: 396.4}, 6 => { Type: :aRNAl_bac, State: :processed, filtered: 321.9}, 7 => { Type: :aRNAl_bac, State: :processed, filtered: 231.6}, 8 => { Type: :aRNAl_bac, State: :processed, filtered: 221.5}, 9 => { Type: :aRNAl_bac, State: :processed, filtered: 195.5}, 10 => { Type: :aRNAl_bac, State: :processed, filtered: 226.9}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @14:03:38.27 -> slot 4=>:dry {4 => { Type: :aRNAl_bac, State: :dry}} @14:03:41.90 -> Cmd.runCartridge @14:03:41.94 Selecting Cartridge 4 @14:03:42.66 Preparing to filter cartridge 4 @14:03:42.95 Bypass.open @14:03:43.69 Toroid.in :hold @14:03:43.79 Toroid.seek :crack @14:03:45.37 Toroid.seek :cartridge @14:03:46.36 Toroid.in :default @14:03:46.46 Toroid.seek :clear @14:03:48.13 Exhaust.open @14:03:49.10 Pressurizing cartridge to 26psi above 14.7psia @14:03:49.13 SamplePump.setPosition! 0ml @14:03:49.21 Intake.open @14:03:49.88 Bypass.close @14:03:50.54 Exhaust.close @14:03:51.41 Pressure.in :default @14:03:51.51 Pressure.hold @14:03:51.76 SamplePump.seek 2.3ml,42 seconds @14:04:02.59 Pressure.stop @14:04:02.69 Intake.close @14:04:03.60 Pressurized cartridge with 0.502ml to 26.0psi @14:04:03.62 Isolated @34.5psia (19.8psi) @14:04:03.66 Verifying cartridge holds at least 0.65..0.85 of 34.5psia @14:04:03.73 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @14:04:08.40 Cartridge pressure fell 1% to 34.3psia @14:04:08.53 Sampling 1000.0ml in 1:25:20 @14:04:08.56 SamplePump.setPosition! 0ml @14:04:08.65 Exhaust.open @14:04:09.27 Intake.open @14:04:10.18 Pressure.in :default @14:04:10.27 Pressure.hold @14:04:10.67 SamplePump.in :sample @14:04:10.78 SamplePump.seek 1000ml,1:23:50 @14:04:13.17 Cartridge 4 filtering 1/1000ml at 0.72ml/s with 24.2psi vacuum 5.3m deep (22.6psia) @14:05:13.18 Cartridge 4 filtering 37/1000ml at 0.57ml/s with 19.0psi vacuum @14:06:13.20 Cartridge 4 filtering 73/1000ml at 0.61ml/s with 32.6psi vacuum @14:07:13.18 Cartridge 4 filtering 107/1000ml at 0.61ml/s with 16.0psi vacuum 8.3m deep (27.0psia) @14:08:13.18 Cartridge 4 filtering 140/1000ml at 0.57ml/s with 33.0psi vacuum @14:09:13.18 Cartridge 4 filtering 169/1000ml at 0.42ml/s with 22.7psi vacuum @14:10:13.17 Cartridge 4 filtering 196/1000ml at 0.38ml/s with 20.4psi vacuum @14:11:13.19 Cartridge 4 filtering 220/1000ml at 0.45ml/s with 14.8psi vacuum @14:12:13.19 Cartridge 4 filtering 242/1000ml at 0.23ml/s with 15.1psi vacuum @14:13:13.18 Cartridge 4 filtering 261/1000ml at 0.31ml/s with 19.8psi vacuum 2.0m deep (17.6psia) @14:14:13.18 Cartridge 4 filtering 279/1000ml at 0.30ml/s with 24.1psi vacuum 1.6m deep (17.0psia) @14:15:13.18 Cartridge 4 filtering 296/1000ml at 0.28ml/s with 27.1psi vacuum @14:16:13.84 Cartridge 4 filtering 311/1000ml at 0.34ml/s with 23.9psi vacuum @14:17:13.19 Cartridge 4 filtering 326/1000ml at 0.24ml/s with 23.6psi vacuum @14:17:47.11 Flow averaged 0.41ml/s over 13:37 @14:17:47.18 Waiting up to 11 seconds for vacuum to reduce from 27.2 to 18.0psi @14:17:47.79 Relieved excess vacuum in .7 seconds @14:17:47.83 SamplePump.seek 1000ml,56:00 @14:17:58.23 Flow averaged 0.22ml/s over 11 seconds @14:17:58.30 Waiting up to 9 seconds for vacuum to reduce from 26.4 to 18.0psi @14:17:58.90 Relieved excess vacuum in .7 seconds @14:17:58.95 SamplePump.seek 1000ml,55:48 @14:18:07.81 Flow estimate reduced to 0.18ml/s @14:18:07.84 Intake.close @14:18:07.91 Exhaust.close @14:18:08.25 Toroid.in :hold @14:18:08.36 Toroid.seek :bypass @14:18:10.05 Toroid.in :default @14:18:10.16 Toroid.seek :clear @14:18:11.80 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @14:18:11.84 Pressure.stop @14:18:12.11 Sampled 338.3ml @14:18:12.79 Plunge.seek :reagent @14:18:13.72 Sample loop closed. Ready to Deliver Reagents @14:18:13.75 Archive.seek :sealed @14:18:17.44 Archive.seek :evac @14:18:28.85 Session Begun @14:18:31.44 delay 1:00 @14:19:13.85 -> exit @14:19:13.87 Session Ended @14:19:31.47 Archive.seek :clear @14:19:48.61 Sample preserved. Puck Full. :PROCESSED @14:21:42.11 -> Cmd.runCartridge @14:21:42.15 Selecting Cartridge 3 @14:21:42.35 Carousel.in :default @14:21:42.51 Carousel.home.seek 4 @14:21:42.97 Air.in :unlocking @14:21:43.16 Air.seek :clear @14:21:44.57 Lysis1.in :unlocking @14:21:44.75 Lysis1.seek :clear @14:21:44.85 Plunge.in :unlocking @14:21:44.98 Plunge.seek :clear @14:21:46.21 Carousel.seek 3 @14:21:47.90 Lysis1.in :fast @14:21:48.00 Lysis1.seek :locked @14:21:50.28 Plunge.in :default @14:21:50.42 Plunge.seek :locked @14:21:50.56 Air.in :fast @14:21:50.66 Air.seek :locked @14:21:52.21 Carousel.reconfigure :locked @14:21:52.31 Carousel.jog 0 @14:21:53.01 Mounted archive Cartridge @14:21:53.43 Preparing to filter cartridge 3 @14:21:53.79 Priming sample loop w/100ml, bypass w/10ml @14:21:53.81 SamplePump.setPosition! 0ml @14:21:53.91 Bypass.open @14:21:55.33 Intake.open @14:21:56.05 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @14:21:58.64 Vacuum tare is 20% of full scale @14:21:58.83 Sea pressure (Abs) tare is 10% of full scale @14:21:59.02 Pressure.in :default @14:21:59.11 Pressure.hold @14:21:59.40 SamplePump.in :prime @14:21:59.50 SamplePump.seek 10ml,59 seconds @14:22:11.15 Pressure.stop @14:22:11.24 SamplePump.setPosition! 0ml @14:22:11.31 Exhaust.open @14:22:12.72 Bypass.close @14:22:14.32 Pressure.in :default @14:22:14.41 Pressure.hold @14:22:14.80 SamplePump.in :prime @14:22:14.90 SamplePump.seek 100ml,5:16 @14:24:08.58 Pressure.stop @14:24:09.21 Bypass.open @14:24:09.95 Intake.close @14:24:10.72 Toroid.in :hold @14:24:10.81 Toroid.seek :crack @14:24:12.38 Toroid.seek :cartridge @14:24:13.37 Toroid.in :default @14:24:13.48 Toroid.seek :clear @14:24:15.53 Pressurizing cartridge to 26psi above 14.3psia @14:24:15.55 SamplePump.setPosition! 0ml @14:24:15.65 Intake.open @14:24:16.31 Bypass.close @14:24:16.98 Exhaust.close @14:24:17.87 Pressure.in :default @14:24:17.96 Pressure.hold @14:24:18.21 SamplePump.in :charge @14:24:18.31 SamplePump.seek 2.3ml,42 seconds @14:24:27.66 Pressure.stop @14:24:27.81 Intake.close @14:24:28.65 Pressurized cartridge with 0.419ml to 26.5psi @14:24:28.67 Isolated @35.6psia (21.3psi) @14:24:28.71 Verifying cartridge holds at least 0.65..0.85 of 35.6psia @14:24:28.77 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @14:24:33.48 Cartridge pressure fell 7% to 33.1psia @14:24:33.61 Sampling 1000.0ml in 1:25:20 @14:24:33.64 SamplePump.setPosition! 0ml @14:24:33.72 Exhaust.open @14:24:34.35 Intake.open @14:24:35.21 Pressure.in :default @14:24:35.31 Pressure.hold @14:24:35.59 Sea 2.6m deep (18.5psia) @14:24:36.43 SamplePump.in :sample @14:24:36.54 SamplePump.seek 1000ml,1:23:50 @14:24:38.21 Cartridge 3 filtering 1/1000ml at 0.64ml/s with 8.5psi vacuum 4.1m deep (20.8psia) @14:25:38.22 Cartridge 3 filtering 36/1000ml at 0.57ml/s with 29.8psi vacuum @14:26:38.21 Cartridge 3 filtering 71/1000ml at 0.55ml/s with 8.5psi vacuum @14:27:38.21 Cartridge 3 filtering 105/1000ml at 0.62ml/s with 20.0psi vacuum 9.5m deep (28.7psia) @14:28:38.20 Cartridge 3 filtering 137/1000ml at 0.55ml/s with 14.1psi vacuum @14:29:38.21 Cartridge 3 filtering 167/1000ml at 0.50ml/s with 10.5psi vacuum 2.3m deep (18.1psia) @14:30:38.21 Cartridge 3 filtering 194/1000ml at 0.45ml/s with 6.8psi vacuum 1.8m deep (17.4psia) @14:31:38.21 Cartridge 3 filtering 220/1000ml at 0.51ml/s with 28.8psi vacuum 8.8m deep (27.7psia) @14:32:38.21 Cartridge 3 filtering 243/1000ml at 0.50ml/s with 19.6psi vacuum 13.9m deep (35.3psia) @14:33:38.21 Cartridge 3 filtering 264/1000ml at 0.33ml/s with 20.5psi vacuum @14:34:38.21 Cartridge 3 filtering 283/1000ml at 0.41ml/s with 17.2psi vacuum 3.2m deep (19.4psia) @14:35:38.21 Cartridge 3 filtering 301/1000ml at 0.37ml/s with 38.8psi vacuum 6.7m deep (24.5psia) @14:36:38.21 Cartridge 3 filtering 317/1000ml at 0.38ml/s with 21.5psi vacuum 12.5m deep (33.1psia) @14:37:38.21 Cartridge 3 filtering 333/1000ml at 0.20ml/s with 38.1psi vacuum @14:38:38.21 Cartridge 3 filtering 347/1000ml at 0.26ml/s with 10.9psi vacuum 1.8m deep (17.3psia) @14:38:44.91 Flow averaged 0.41ml/s over 14:09 @14:38:44.99 Waiting up to 10 seconds for vacuum to reduce from 27.0 to 18.0psi @14:38:45.59 Relieved excess vacuum in .7 seconds @14:38:45.64 SamplePump.seek 1000ml,54:48 @14:38:53.09 Flow estimate reduced to 0.33ml/s @14:38:53.16 Waiting up to 11 seconds for vacuum to reduce from 27.0 to 18.0psi @14:38:53.76 Relieved excess vacuum in .7 seconds @14:38:53.82 SamplePump.seek 1000ml,54:40 @14:39:02.67 Flow estimate reduced to 0.26ml/s @14:39:02.74 Waiting up to 11 seconds for vacuum to reduce from 27.1 to 18.0psi @14:39:03.37 Relieved excess vacuum in .7 seconds @14:39:03.43 SamplePump.seek 1000ml,54:30 @14:39:09.50 Flow estimate reduced to 0.21ml/s @14:39:09.57 Waiting up to 11 seconds for vacuum to reduce from 27.0 to 18.0psi @14:39:10.18 Relieved excess vacuum in .7 seconds @14:39:10.22 SamplePump.seek 1000ml,54:23 @14:39:14.94 Flow estimate reduced to 0.17ml/s @14:39:14.96 Intake.close @14:39:15.08 Exhaust.close @14:39:15.40 Toroid.in :hold @14:39:15.50 Toroid.seek :bypass @14:39:17.18 Toroid.in :default @14:39:17.91 Toroid.seek :clear @14:39:19.65 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @14:39:19.68 Pressure.stop @14:39:19.97 Sampled 354.4ml @14:39:20.63 Plunge.seek :reagent @14:39:21.56 Sample loop closed. Ready to Deliver Reagents @14:39:21.59 Archive.seek :sealed @14:39:25.28 Archive.seek :evac @14:39:39.26 delay 1:00 @14:40:39.29 Archive.seek :clear @14:40:56.45 Sample preserved. Puck Full. :PROCESSED @14:43:08.05 -> Cmd.runCartridge @14:43:08.10 Selecting Cartridge 2 @14:43:08.30 Carousel.in :default @14:43:08.46 Carousel.home.seek 3 @14:43:08.91 Air.in :unlocking @14:43:09.09 Air.seek :clear @14:43:10.51 Lysis1.in :unlocking @14:43:10.70 Lysis1.seek :clear @14:43:10.74 Plunge.in :unlocking @14:43:10.90 Plunge.seek :clear @14:43:12.15 Carousel.seek 2 @14:43:13.19 Lysis1.in :fast @14:43:13.29 Lysis1.seek :locked @14:43:15.60 Plunge.in :default @14:43:15.79 Plunge.seek :locked @14:43:15.99 Air.in :fast @14:43:16.10 Air.seek :locked @14:43:17.68 Carousel.reconfigure :locked @14:43:17.80 Carousel.jog 0 @14:43:18.53 Mounted archive Cartridge @14:43:18.97 Preparing to filter cartridge 2 @14:43:19.96 Priming sample loop w/100ml, bypass w/10ml @14:43:19.98 SamplePump.setPosition! 0ml @14:43:20.07 Bypass.open @14:43:21.51 Intake.open @14:43:22.24 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @14:43:24.83 Vacuum tare is 20% of full scale @14:43:25.02 Sea pressure (Abs) tare is 10% of full scale @14:43:25.21 Pressure.in :default @14:43:25.31 Pressure.hold @14:43:25.60 SamplePump.in :prime @14:43:25.71 SamplePump.seek 10ml,59 seconds @14:43:37.39 Pressure.stop @14:43:37.48 SamplePump.setPosition! 0ml @14:43:37.56 Exhaust.open @14:43:38.92 Bypass.close @14:43:40.47 Pressure.in :default @14:43:40.56 Pressure.hold @14:43:40.95 SamplePump.in :prime @14:43:41.05 SamplePump.seek 100ml,5:16 @14:45:34.73 Pressure.stop @14:45:34.84 Bypass.open @14:45:35.46 Intake.close @14:45:36.25 Toroid.in :hold @14:45:36.34 Toroid.seek :crack @14:45:37.92 Toroid.seek :cartridge @14:45:38.90 Toroid.in :default @14:45:38.99 Toroid.seek :clear @14:45:40.97 Pressurizing cartridge to 26psi above 14.3psia @14:45:41.00 SamplePump.setPosition! 0ml @14:45:41.11 Intake.open @14:45:41.78 Bypass.close @14:45:42.42 Exhaust.close @14:45:43.26 Pressure.in :default @14:45:43.36 Pressure.hold @14:45:44.28 SamplePump.in :charge @14:45:44.38 SamplePump.seek 2.3ml,42 seconds @14:45:54.84 Pressure.stop @14:45:54.94 Intake.close @14:45:55.76 Pressurized cartridge with 0.527ml to 26.2psi @14:45:55.77 Isolated @28.2psia (13.9psi) @14:45:55.80 Verifying cartridge holds at least 0.65..0.85 of 28.2psia @14:45:55.87 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @14:46:02.55 Cartridge pressure fell 34% to 18.7psia @14:46:02.71 Toroid.in :hold @14:46:02.80 Toroid.seek :bypass @14:46:04.47 Toroid.in :default @14:46:04.57 Toroid.seek :clear @14:46:06.31 Cartridge::Sampler::Leaky in FILTERING -- Retained only 18.7psia @14:46:06.33 Waiting to Resume from Checkpoint "Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi" @14:54:58.35 Session Begun @14:55:16.93 -> quit @14:55:16.95 Session Ended @14:56:31.15 Cmd::Error in brent -- Not Filtering @14:56:31.21 UserAbort in brent -- User Abort!! @14:56:33.41 -> Cmd.runCartridge @14:56:33.45 Selecting Cartridge 1 @14:56:33.66 Carousel.in :default @14:56:33.82 Carousel.home.seek 2 @14:56:34.29 Air.in :unlocking @14:56:34.47 Air.seek :clear @14:56:35.90 Lysis1.in :unlocking @14:56:36.10 Lysis1.seek :clear @14:56:36.14 Plunge.in :unlocking @14:56:36.33 Plunge.seek :clear @14:56:37.37 Carousel.seek 1 @14:56:38.98 UserAbort in brent -- User Abort!! @14:56:45.18 UserAbort in brent -- User Abort!! @14:56:50.91 UserAbort in brent -- User Abort!! @14:56:57.47 -> slot {1 => { Type: :aRNAl_bac, State: :dry}, 2 => { Type: :aRNAl_bac, State: :leaky}, 3 => { Type: :aRNAl_bac, State: :processed, filtered: 354.4}, 4 => { Type: :aRNAl_bac, State: :processed, filtered: 338.3}, 5 => { Type: :aRNAl_bac, State: :processed, filtered: 396.4}, 6 => { Type: :aRNAl_bac, State: :processed, filtered: 321.9}, 7 => { Type: :aRNAl_bac, State: :processed, filtered: 231.6}, 8 => { Type: :aRNAl_bac, State: :processed, filtered: 221.5}, 9 => { Type: :aRNAl_bac, State: :processed, filtered: 195.5}, 10 => { Type: :aRNAl_bac, State: :processed, filtered: 226.9}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @14:57:11.14 -> slot 1..3 {1 => { Type: :aRNAl_bac, State: :dry}, 2 => { Type: :aRNAl_bac, State: :leaky}, 3 => { Type: :aRNAl_bac, State: :processed, filtered: 354.4}} @14:57:18.28 -> slot 2=>:dry {2 => { Type: :aRNAl_bac, State: :dry}} @14:57:25.38 -> Cmd.runCartridge @14:57:26.10 Toroid.seek :clear @14:57:26.22 Carousel.in :default @14:57:26.38 Carousel.home.seek 1 @14:57:26.67 Selecting Cartridge 2 @14:57:26.93 Carousel.seek 2 @14:57:28.01 Lysis1.in :fast @14:57:28.10 Lysis1.seek :locked @14:57:30.39 Plunge.in :default @14:57:30.53 Plunge.seek :locked @14:57:30.68 Air.in :fast @14:57:30.77 Air.seek :locked @14:57:32.33 Carousel.reconfigure :locked @14:57:32.43 Carousel.jog 0 @14:57:33.13 Mounted archive Cartridge @14:57:33.55 Preparing to filter cartridge 2 @14:57:33.84 Bypass.open @14:57:34.56 Toroid.in :hold @14:57:34.66 Toroid.seek :crack @14:57:36.23 Toroid.seek :cartridge @14:57:37.21 Toroid.in :default @14:57:37.30 Toroid.seek :clear @14:57:39.01 Exhaust.open @14:57:40.63 Pressurizing cartridge to 26psi above 14.3psia @14:57:40.65 SamplePump.setPosition! 0ml @14:57:40.73 Intake.open @14:57:41.39 Bypass.close @14:57:42.03 Exhaust.close @14:57:42.90 Pressure.in :default @14:57:42.99 Pressure.hold @14:57:43.25 SamplePump.seek 2.3ml,42 seconds @14:57:51.10 Pressure.stop @14:57:51.23 Intake.close @14:57:52.03 Pressurized cartridge with 0.294ml to 26.1psi @14:57:52.04 Isolated @30.1psia (15.8psi) @14:57:52.07 Verifying cartridge holds at least 0.65..0.85 of 30.1psia @14:57:52.13 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @14:57:57.49 Toroid.in :hold @14:57:57.59 Toroid.seek :bypass @14:57:59.27 Toroid.in :default @14:57:59.39 Toroid.seek :clear @14:58:01.13 Cartridge::Sampler::Leaky in FILTERING -- Isolated cartridge pressure fell by 36% to 19.3psia @14:58:01.15 Waiting to Resume from Checkpoint "Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi" @14:58:09.25 Cmd::Error in brent -- Not Filtering @14:58:09.31 UserAbort in brent -- User Abort!! @14:58:13.13 -> Cmd.runCartridge @14:58:13.17 Selecting Cartridge 1 @14:58:13.41 Carousel.in :default @14:58:13.57 Carousel.home.seek 2 @14:58:14.03 Air.in :unlocking @14:58:14.19 Air.seek :clear @14:58:15.56 Lysis1.in :unlocking @14:58:15.74 Lysis1.seek :clear @14:58:15.83 Plunge.in :unlocking @14:58:16.60 Plunge.seek :clear @14:58:17.44 Carousel.seek 1 @14:58:18.48 Lysis1.in :fast @14:58:18.58 Lysis1.seek :locked @14:58:20.87 Plunge.in :default @14:58:20.97 Plunge.seek :locked @14:58:21.16 Air.in :fast @14:58:21.26 Air.seek :locked @14:58:22.82 Carousel.reconfigure :locked @14:58:22.92 Carousel.jog 0 @14:58:23.62 Mounted archive Cartridge @14:58:24.01 Preparing to filter cartridge 1 @14:58:24.31 Bypass.open @14:58:25.00 Toroid.in :hold @14:58:25.09 Toroid.seek :crack @14:58:26.66 Toroid.seek :cartridge @14:58:27.64 Toroid.in :default @14:58:27.74 Toroid.seek :clear @14:58:29.40 Exhaust.open @14:58:30.39 Pressurizing cartridge to 26psi above 13.8psia @14:58:30.41 SamplePump.setPosition! 0ml @14:58:30.50 Intake.open @14:58:31.16 Bypass.close @14:58:31.81 Exhaust.close @14:58:32.71 Pressure.in :default @14:58:32.80 Pressure.hold @14:58:33.06 SamplePump.seek 2.3ml,42 seconds @14:58:46.32 Pressure.stop @14:58:46.40 Intake.close @14:58:47.19 Pressurized cartridge with 0.852ml to 26.7psi @14:58:47.21 Isolated @38.7psia (24.9psi) @14:58:47.25 Verifying cartridge holds at least 0.65..0.85 of 38.7psia @14:58:47.30 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @14:58:52.00 Cartridge pressure fell 5% to 36.7psia @14:58:52.13 Sampling 1000.0ml in 1:25:20 @14:58:52.16 SamplePump.setPosition! 0ml @14:58:52.25 Exhaust.open @14:58:52.89 Intake.open @14:58:53.77 Pressure.in :default @14:58:53.86 Pressure.hold @14:58:54.26 SamplePump.in :sample @14:58:54.36 SamplePump.seek 1000ml,1:23:50 @14:58:56.75 Cartridge 1 filtering 1/1000ml at 0.60ml/s with 13.5psi vacuum @14:59:56.76 Cartridge 1 filtering 37/1000ml at 0.57ml/s with 26.4psi vacuum @15:00:56.76 Cartridge 1 filtering 72/1000ml at 0.62ml/s with 22.2psi vacuum 6.5m deep (24.4psia) @15:01:56.76 Cartridge 1 filtering 104/1000ml at 0.45ml/s with 24.3psi vacuum @15:02:56.76 Cartridge 1 filtering 131/1000ml at 0.50ml/s with 12.2psi vacuum 7.9m deep (26.4psia) @15:03:56.76 Cartridge 1 filtering 154/1000ml at 0.44ml/s with 15.8psi vacuum @15:04:56.76 Cartridge 1 filtering 173/1000ml at 0.20ml/s with 29.2psi vacuum @15:05:56.76 Cartridge 1 filtering 189/1000ml at 0.27ml/s with 8.0psi vacuum @15:06:56.76 Cartridge 1 filtering 204/1000ml at 0.20ml/s with 25.1psi vacuum @15:07:22.03 Flow averaged 0.41ml/s over 8:28 @15:07:22.11 Waiting up to 14 seconds for vacuum to reduce from 28.4 to 18.0psi @15:07:22.71 Relieved excess vacuum in .7 seconds @15:07:22.75 SamplePump.seek 1000ml,1:06:20 @15:07:27.44 Flow estimate reduced to 0.33ml/s @15:07:27.52 Waiting up to 15 seconds for vacuum to reduce from 29.0 to 18.0psi @15:07:28.12 Relieved excess vacuum in .7 seconds @15:07:28.18 SamplePump.seek 1000ml,1:06:15 @15:07:31.41 Flow estimate reduced to 0.26ml/s @15:07:31.49 Waiting up to 15 seconds for vacuum to reduce from 28.9 to 18.0psi @15:07:32.76 Relieved excess vacuum in 1.3 seconds @15:07:32.82 SamplePump.seek 1000ml,1:06:12 @15:07:35.94 Flow estimate reduced to 0.21ml/s @15:07:36.02 Waiting up to 13 seconds for vacuum to reduce from 28.0 to 18.0psi @15:07:36.63 Relieved excess vacuum in .7 seconds @15:07:36.70 SamplePump.seek 1000ml,1:06:08 @15:07:39.82 Flow estimate reduced to 0.17ml/s @15:07:39.86 Intake.close @15:07:39.95 Exhaust.close @15:07:40.27 Toroid.in :hold @15:07:40.38 Toroid.seek :bypass @15:07:42.07 Toroid.in :default @15:07:42.18 Toroid.seek :clear @15:07:43.83 Cartridge::Sampler::Clogged in FILTERING -- Cartridge clogged @15:07:43.86 Pressure.stop @15:07:44.16 Sampled 213.0ml @15:07:44.83 Plunge.seek :reagent @15:07:45.77 Sample loop closed. Ready to Deliver Reagents @15:07:45.80 Archive.seek :sealed @15:07:49.49 Archive.seek :evac @15:08:03.48 delay 1:00 @15:09:03.51 Archive.seek :clear @15:09:20.66 Sample preserved. Puck Full. :PROCESSED @15:09:46.94 -> slot 2 {2 => { Type: :aRNAl_bac, State: :leaky}} @15:09:54.52 -> slot 2->:dry @15:09:54.54 SyntaxError in brent -- compile error brent:60: syntax error, unexpected '>' slot 2->:dry ^ @15:10:00.94 -> slot 2=>:dry {2 => { Type: :aRNAl_bac, State: :dry}} @15:10:23.40 -> runCartridge @15:10:23.44 Selecting Cartridge 2 @15:10:23.65 Carousel.in :default @15:10:23.82 Carousel.home.seek 1 @15:10:24.28 Air.in :unlocking @15:10:24.46 Air.seek :clear @15:10:25.87 Lysis1.in :unlocking @15:10:26.06 Lysis1.seek :clear @15:10:26.13 Plunge.in :unlocking @15:10:26.28 Plunge.seek :clear @15:10:27.52 Carousel.seek 2 @15:10:29.21 Lysis1.in :fast @15:10:29.31 Lysis1.seek :locked @15:10:31.64 Plunge.in :default @15:10:31.75 Plunge.seek :locked @15:10:31.94 Air.in :fast @15:10:32.04 Air.seek :locked @15:10:33.61 Carousel.reconfigure :locked @15:10:33.71 Carousel.jog 0 @15:10:34.44 Mounted archive Cartridge @15:10:34.83 Preparing to filter cartridge 2 @15:10:35.30 Priming sample loop w/100ml, bypass w/10ml @15:10:35.33 SamplePump.setPosition! 0ml @15:10:35.47 Bypass.open @15:10:36.87 Intake.open @15:10:37.59 Waiting up to 20 seconds for sea pressure to stabilize +/-0.50psi @15:10:40.17 Vacuum tare is 20% of full scale @15:10:40.36 Sea pressure (Abs) tare is 10% of full scale @15:10:40.55 Pressure.in :default @15:10:40.64 Pressure.hold @15:10:40.91 SamplePump.in :prime @15:10:41.01 SamplePump.seek 10ml,59 seconds @15:10:52.68 Pressure.stop @15:10:52.77 SamplePump.setPosition! 0ml @15:10:52.85 Exhaust.open @15:10:54.22 Bypass.close @15:10:55.75 Pressure.in :default @15:10:55.85 Pressure.hold @15:10:56.26 SamplePump.in :prime @15:10:56.37 SamplePump.seek 100ml,5:16 @15:12:50.03 Pressure.stop @15:12:50.19 Bypass.open @15:12:51.35 Intake.close @15:12:52.20 Toroid.in :hold @15:12:52.30 Toroid.seek :crack @15:12:53.87 Toroid.seek :cartridge @15:12:54.85 Toroid.in :default @15:12:54.95 Toroid.seek :clear @15:12:56.96 Pressurizing cartridge to 26psi above 14.6psia @15:12:56.99 SamplePump.setPosition! 0ml @15:12:57.09 Intake.open @15:12:57.73 Bypass.close @15:12:58.41 Exhaust.close @15:12:59.26 Pressure.in :default @15:12:59.39 Pressure.hold @15:12:59.68 SamplePump.in :charge @15:12:59.78 SamplePump.seek 2.3ml,42 seconds @15:13:06.58 Pressure.stop @15:13:06.68 Intake.close @15:13:07.53 Pressurized cartridge with 0.218ml to 26.2psi @15:13:07.55 Isolated @27.8psia (13.1psi) @15:13:07.59 Verifying cartridge holds at least 0.65..0.85 of 27.8psia @15:13:07.66 Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi @15:13:11.52 Toroid.in :hold @15:13:11.63 Toroid.seek :bypass @15:13:13.31 Toroid.in :default @15:13:13.45 Toroid.seek :clear @15:13:15.20 Cartridge::Sampler::Leaky in FILTERING -- Isolated cartridge pressure fell by 36% to 17.8psia @15:13:15.22 Waiting to Resume from Checkpoint "Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi" @15:13:25.03 Cmd::Error in brent -- Not Filtering @15:13:25.10 UserAbort in brent -- User Abort!! @15:13:32.77 -> slot {1 => { Type: :aRNAl_bac, State: :processed, filtered: 213.0}, 2 => { Type: :aRNAl_bac, State: :leaky}, 3 => { Type: :aRNAl_bac, State: :processed, filtered: 354.4}, 4 => { Type: :aRNAl_bac, State: :processed, filtered: 338.3}, 5 => { Type: :aRNAl_bac, State: :processed, filtered: 396.4}, 6 => { Type: :aRNAl_bac, State: :processed, filtered: 321.9}, 7 => { Type: :aRNAl_bac, State: :processed, filtered: 231.6}, 8 => { Type: :aRNAl_bac, State: :processed, filtered: 221.5}, 9 => { Type: :aRNAl_bac, State: :processed, filtered: 195.5}, 10 => { Type: :aRNAl_bac, State: :processed, filtered: 226.9}, [31,30] => { Type: :archiveNull_bac, State: :reserved, was: :dry}, 34..32 => { Type: :archiveNull_bac, State: :processed, filtered: 134}, 35 => { Type: :archive_bac, State: :failedLoading}, 36 => { Type: :archive_bac, State: :processed, filtered: 150}} @15:13:45.18 -> slot 1..3 {1 => { Type: :aRNAl_bac, State: :processed, filtered: 213.0}, 2 => { Type: :aRNAl_bac, State: :leaky}, 3 => { Type: :aRNAl_bac, State: :processed, filtered: 354.4}} @15:13:59.90 -> Cmd.stop @15:14:00.04 SamplePump.stop @15:14:00.14 Carousel.in :default @15:14:00.31 Carousel.home.seek 2 @15:14:00.68 Plunge.seek :locked @15:14:01.66 Air.in :unlocking @15:14:01.85 Air.seek :clear @15:14:01.91 Lysis1.in :unlocking @15:14:02.18 Lysis1.seek :clear @15:14:03.99 Gate.power :motor,:OFF @15:14:04.01 Gate.power :core,:OFF @15:14:04.07 Gate.power :analytic1,:OFF @15:14:04.11 Gate.power :analytic2,:OFF @15:14:04.15 Gate.power :analytic3,:OFF @15:14:04.19 Gate.power :main,:OFF @15:14:04.24 Safely stopped and ready to power off :STOPPED @15:25:47.87 -> exit @15:25:47.91 Thread::Aborted in FILTERING -- "Aborted by brent" @15:25:47.96 Session Ended @15:25:47.98 Waiting to Resume from Checkpoint "Waiting up to 20 seconds for cartridge pressure to stabilize +/-1.50psi" @16:01:41.06 Session Begun @16:01:53.76 -> ESP.ready! @16:01:53.82 Gate.power :main,:ON,limit to 5000mA @16:01:53.85 Gate.power :analytic1,:ON,limit to 5000mA @16:01:53.89 Gate.power :analytic2,:ON,limit to 5000mA @16:01:53.92 Gate.power :analytic3,:ON,limit to 5000mA @16:01:54.01 Powering core bus @16:01:57.85 Archive.configure :default @16:01:57.97 Air.configure :default @16:01:58.07 Lysis1.configure :default @16:01:58.16 Lysis2.configure :default @16:01:58.27 Plunge.configure :default @16:01:58.39 SamplePump.configure :default @16:01:58.52 Toroid.configure :default @16:01:58.63 Carousel.configure :default @16:01:58.75 Pressure.configure :default @16:01:58.88 ExtraPump.configure :default @16:01:58.97 All elf controllers running firmware version 4.794 @16:01:59.00 Gate.power :motor,:ON,limit to 5000mA @16:01:59.53 Air.home.jog 0 @16:01:59.62 Archive.home.jog 0 @16:02:00.18 Toroid.home.jog 0 @16:02:00.21 Plunge.home.jog 0 @16:02:00.28 Lysis1.home.jog 0 @16:02:00.36 Lysis2.home.jog 0 @16:02:00.39 Carousel.home.jog 0 @16:02:01.00 Archive.in :homing @16:02:01.15 Air.in :homing @16:02:01.28 Archive.jog 1362 @16:02:01.32 Air.jog 1360 @16:02:01.65 Plunge.in :homing @16:02:01.69 Lysis2.in :homing @16:02:01.75 Toroid.in :homing @16:02:01.82 Lysis1.in :homing @16:02:02.02 Plunge.jog 811 @16:02:02.15 Lysis2.jog 1360 @16:02:02.23 Toroid.jog 608 @16:02:02.31 Lysis1.jog 1346 @16:02:03.20 Plunge.setRawPosition! 50 @16:02:03.24 Air.setRawPosition! 50 @16:02:03.27 Archive.setRawPosition! 50 @16:02:03.47 Plunge.seek :home @16:02:03.51 Air.seek :home @16:02:03.65 Archive.seek :home @16:02:03.93 Plunge.in :default @16:02:03.95 Lysis2.setRawPosition! 50 @16:02:04.10 Lysis2.seek :home @16:02:04.26 Lysis1.setRawPosition! 50 @16:02:04.31 Air.in :default @16:02:04.42 Archive.in :default @16:02:04.51 Lysis1.seek :home @16:02:04.70 Lysis2.in :default @16:02:04.87 Lysis1.in :default @16:02:05.12 Toroid.setRawPosition! 0 @16:02:05.21 Toroid.seek :home @16:02:05.31 Toroid.in :default @16:02:05.46 Toroid.seek :clear @16:02:07.10 Carousel.in :default @16:02:07.26 Carousel.home.seek 2 Archive = Archive Syringe (ArS) clear Air = Air Syringe (AirS) clear Lysis1 = Lysis Syringe #1 (LyS1) clear Lysis2 = Lysis Syringe #2 (LyS2) clear Plunge = Plunge Valve (PV) clear Handoff Valve::Manifold selects blocked SamplePump = Sample Pump (SP) Not yet Homed! Intake is closed Exhaust is closed Bypass = Bypass (PB) is closed Toroid = Toroid Valve (TV) clear Carousel = Storage Carousel (SC) at 2 Pressure = Absolute Pressure (Leak) Sensor @17.8psia Toxicant = External Toxicant Valve::Manifold selects exhaust @16:02:13.65 -> SC.to 2 @16:02:13.67 Carousel.seek 2 Storage Carousel (SC) at 2 @16:02:50.77 -> SC.to 10 @16:02:50.80 Carousel.seek 10 Storage Carousel (SC) at 10 @16:03:10.95 -> exit @16:03:10.97 Session Ended @16:08:40.47 -> exut :exut @16:08:42.11 -> exit @16:08:42.13 Session Ended